Mechanical Services Sample Clauses

Mechanical Services. Plumbing - Checking availability of water and informing concerned authorities for further action. • Water Pumps & Hydro Pneumatic System – Operations and minor service of pumps like greasing, checking alignment, tightening & replacement of gland packing, cleaning strainers. • All Drainage System – Checking and clearing drains choke ups. • Replacement of washers, taps & other fittings. • Minor repairs to all Plumbing accessories. • Carpentry - Repairing creaky doors, repairs of the floor springs, door closures, minor woodwork and polishing/painting jobs & lamination, fixing of paintings. Repair of the furniture and chairs
AutoNDA by SimpleDocs
Mechanical Services. Equipment and operation 1 year 1 year General mechanical installation 2 years 2 years Heat pump - indoor and outdoor units 5 years 2 years Metal windows and doors Metalwork Operable Walls Painting Plumbing Proprietary partitions Roller/tilt/sectional doors Roofing Boiler 5 years 2 years Pumps 5 years 2 years Building management system 2 years 2 years Radiators 20 years 2 years Fans 5 years 2 years Underfloor heating - piped 25 years 25 years Dust extraction unit 2 years 2 years Spray booth unit 2 years 2 years Compressed air system unit 2 years 2 years Aluminium windows and doors 5 years 2 years Steel windows and doors 5 years 2 years Fluoropolymer coating 10 years N/A Polyester coating 10 years N/A Anodising 10 years N/A Fabrication 10 years 2 years Operable Walls 1 year 1 year Exterior painting 5 years 2 years Interior painting 5 years 2 years Protective coatings to steelwork 6 years 3 years Intumescent coatings to steelwork 6 years 2 years Anti-Graffiti 5 years 2 years General plumbing installation 2 years 2 years Hot water cylinders 4 years 1 year Boiling water units 3 years 1 year Solar water heating collectors 3 years 1 year Compact laminate partitions 10 years 2 years Hardware items 2 years 2 years Commercial door unit 1 year 1 year Profiled metal roofing 15 years 5 years Metal roofing coating system 15 years N/A Modified bitumen membrane 15 years 5 years Synthetic plastic sheet membrane 15 years 5 years Translucent plastic roofing 15 years 5 years Roof access systems 7 years 7 years 5 years 1 year Retaining walls - concrete, timber Retaining walls - proprietary Paving Asphalt paving Irrigation systems Synthetic sports surface Fencing 10 years 15 years 5 years 5 years 5 years 7 years 5 years 5 years 5 years 1 year 3 years 3 years 3 years 5 years Grid Acoustic panels 15 years 15 years Tanking membrane Wall and floor tiling Waterproofing membrane Window treatments Blinds Curtains Sealants Roofing underlays 15 years 5 years Cappings and flashings 15 years 5 years Rainwater systems - metal 10 years 3 years Skylights and operating system 10 years 5 years Walkways / platforms / stairs 15 years 2 years Roof hatch 10 years 2 years Exterior Interior 10 years 10 years Signage Signage Siteworks Suspended ceilings 3 years 3 years Tanking 20 years 5 years Tiling 5 years 15 years 2 years 5 years 3 years 3 years N/A N/A Add the following Appendix: APPENDIX DHEALTH AND SAFETY REQUIREMENTS
Mechanical Services. Services to be performed on Point Pleasant buses by a certified mechanic shall be $45.00 per hour. Mechanic Helper: Services to be performed on Point Pleasant buses by a non-certified mechanic shall be $20.00 per hour. This Agreement may be terminated with 60-days notice by either party. Xxxxx X. Xxxxxxx, Xx., CPA (date) Xxx X. Xxxxxxxx (date) Business Administrator/Board Secretary Board President Brick Township Board of Education Brick Township Board of Education Xxxxxx X. Xxxxx (date) Xxxx XxxXxxxxxx (date) Business Administrator/Board Secretary Board President
Mechanical Services. This Job Order Contract (JOC) for Mechanical Services (hereinafter referred to as “Contract”) is made and entered into as of the date fully executed by and between County of Orange, a political subdivision of the State of California, (hereinafter referred to as “County”) and ABM Building Solutions, LLC (hereinafter referred to as “Contractor”), which are sometimes individually referred to as “Party”, or collectively referred to as “Parties”.
Mechanical Services. ▪ 4892 Computer Aided Drafting - Statement of Attainment (AQF) ▪ 7773 Computer Aided Drafting - Statement of Attainment (AQF) ▪ 9879 Detail Drafting - Diploma (AQF) ▪ 8256 Detail Drafting and Cad - Certificate III (AQF) ▪ 9976 Detail Drafting Concepts - Certificate II (AQF) ▪ 3442 Drafting Trades - Certificate III (AQF) ▪ 9325 Engineering (Non-Destructive Testing) - Diploma (AQF) ▪ 9975 Engineering - Diploma (AQF) ▪ 9324 Engineering - Higher Engineering Trade (N.D.T.) - Certificate IV (AQF) ▪ 2878 Engineering - Mechanical Trade (Locksmithing) - Certificate III (AQF) ▪ 3452 Engineering - Mechanical Trade (Toolmaking) - Certificate III (AQF) ▪ 6888 Engineering - Mechanical Trade (Watchmaking) - Certificate III (AQF) ▪ 3448 Engineering - Mechanical Trade - Certificate III (AQF) ▪ 6898 Engineering - Refresher - Graduate Certificate (AQF) ▪ 300 Engineering - Technician - Certificate III (AQF) ▪ 6899 Engineering - Technician - Certificate III (AQF) ▪ 9236 Engineering Project Management - Statement of Attainment (AQF) ▪ 7750 Fluid Power Control - Statement of Attainment (AQF) - TAFE PLUS ▪ 9235 Maintenance Management - Statement of Attainment (AQF) ▪ 9878 Maintenance Management - Statement of Attainment (AQF) ▪ 9877 Manufacturing and Engineering - Statement of Attainment (AQF) ▪ 9885 Manufacturing Technology - Diploma (AQF) ▪ 6459 Mechanical Design - Statement of Attainment (AQF) ▪ 9895 Mechanical Engineering - Advanced Diploma (AQF) ▪ 9881 Mechanical Engineering - Diploma (AQF) ▪ 9894 Mechanical Technology - Advanced Diploma (AQF) ▪ 9240 Mechatronics - Advanced Diploma (AQF) ▪ 9893 Naval Architecture - Advanced Diploma (AQF) ▪ 9883 Naval Architecture - Diploma (AQF) ▪ 9892 Naval Architecture Technology - Advanced Diploma (AQF) ▪ 9323 Non-Destructive Testing - Statement of Attainment (AQF) ▪ 9322 Non-Destructive Testing - TAFE Statement ▪ 6896 Steam Plant Operation - TAFE Statement
Mechanical Services. 7.1 reconfigure controls and wiring to Versatemp units to conform to new partition layouts (minimum of one control per room - more than one would be acceptable).
Mechanical Services. A The mechanical services installation will originate from a single boiler house with low temperature hot water mains extended to the office Areas within the suspended ceiling void. B Natural gas boilers will be designed and each sized to manage approximately sixty percent of full load. C Control of the boilers will be fully automatic and incorporate standard frost control and safety devices. D The existing cold water storage tank will be removed and distribution pipework extended throughout the suspended ceiling void for connection into the Toilet Areas. E Hot water services will extend from a central source within the main boiler house with pipework distribution incorporating fully recirculating mains extending through the suspended ceiling void. F A new plant room will be constructed at ground or roof level to accommodate the boiler, and hot water storage. G Heating distribution within the building will involve the use of high heat output radiators connected to compensated circuits which will adjust the flow temperature in relation to outside conditions. H Mechanical ventilation will be provided to the male and female toilet installation. COMPREHENSIVE XXXXXXXXXXXXX XXXXX 00, XXXXX XXXX XXXXXXXX XXXX GB-0SL/4 WEST XXXXXXX, XXXX
AutoNDA by SimpleDocs
Mechanical Services. (See Xxxxx Xxxxx spec. attached but adjusted for open plan office accommodation throughout)
Mechanical Services. 6.01 DESIGN CRITERIA The design is based on the following design criteria.
Mechanical Services. 2.3.1 It is assumed that the building has been fitted out with base mechanical services to a shell and core specification as defined in the British Council for Offices Guide 2009.