Common use of Lightning Protection Clause in Contracts

Lightning Protection. If there is no lightning protection system at the installation site, or if an existing lightning protection system is more than 5m from the antenna location, then Customer shall arrange for the antenna and any other ancillary equipment to be connected to an appropriate lightning protection system and ground. Customer shall comply with all applicable laws, rules and regulations. Customer shall further ensure that the IDU has a potential equalization location with a response resistance of < 2 Ohm. Customer shall also prove a cable trunk for the connection between the antenna and internal Equipment. The maximum distance for the lightning/grounding protection system is 5m for both the antenna and the internal Equipment. Cable specification should be Cu / Fe / Ø 10mm. Fuses Customer shall provide fuses in accordance with the following specifications: For internal Equipment 230 V- 16 A As separate circuits with safety sockets For antenna heating (if applicable) 230 V- 10 A As separate circuits with grounding If antenna AC us used 230 V – I 10 A 10 A As separate circuits with grounding Services Not Included in Standard Installation In addition to the other provisions of this Appendix A, the following are not included in the standard installation. If Customer requests GDS to provide any of the following, then GDS will issue a separate quotation for such services. • Any preliminary work • Laying of cable lines • Construction work, e.g. laying of foundation • Fencing of the antenna unit • Assembly of lightning protection • Use and operation of a crane • Disassembly of any existing equipment • Packaging and crating of any removed/de-installed equipment

Appears in 3 contracts

Samples: Master Service Agreement, Master Service Agreement, Master Service Agreement

AutoNDA by SimpleDocs

Lightning Protection. If there is no lightning protection system at the installation site, or if an existing lightning protection system is more than 5m from the antenna location, then Customer shall arrange for the antenna and any other ancillary equipment to be connected to an appropriate lightning protection system and ground. Customer shall comply with all applicable laws, rules and regulations. Customer shall further ensure that the IDU has a potential equalization location with a response resistance of < 2 Ohm. Customer shall also prove a cable trunk for the connection between the antenna and internal Equipment. The maximum distance for the lightning/grounding protection system is 5m for both the antenna and the internal Equipment. Cable specification should be Cu / Fe / Ø 10mm. Fuses Customer shall provide fuses in accordance with the following specifications: For internal Equipment 230 V- 16 A As separate circuits with safety sockets For antenna heating (if applicable) 230 V- 10 A 10A As separate circuits with grounding If antenna AC us is used 230 V – I 10 A 10 A V- 10A As separate circuits with grounding Services Not Included in Standard Installation In addition to the other provisions of this Appendix A, the following are not included in the standard installation. If Customer requests GDS Tampnet to provide any of the following, then GDS Tampnet will issue a separate quotation for such services. • Any preliminary work • Laying of cable lines • Construction work, e.g. laying of foundation • Fencing of the antenna unit • Assembly of lightning protection • Use and operation of a crane • Disassembly of any existing equipment • Packaging and crating of any removed/de-installed equipment

Appears in 1 contract

Samples: cdn2.hubspot.net

AutoNDA by SimpleDocs
Time is Money Join Law Insider Premium to draft better contracts faster.