LBMP Bus Calculation Method Sample Clauses

LBMP Bus Calculation Method. System marginal costs will be utilized in an ex ante computation to produce Day- Ahead and Real-Time LBMP bus prices using the following equations. The LBMP at bus i can be written as: Where: = LBMP at bus i in $/MWh = the system marginal price at the Reference Bus = Marginal Losses Component of the LBMP at bus i which is the marginal cost of losses at bus i relative to the Reference Bus = Congestion Component of the LBMP at bus i which is the marginal cost of Congestion at bus i relative to the Reference Bus The Marginal Losses Component of the LBMP at any bus i is calculated using the equation: Where: = delivery factor for bus i to the system Reference Bus and: Where: L = NYCA losses; and = injection at bus i The Congestion Component of the LBMP at bus i is calculated using the equation: Where:
AutoNDA by SimpleDocs
LBMP Bus Calculation Method. System marginal costs will be utilized in an ex ante computation to produce Day-Ahead and Real-Time LBMP bus prices using the following equations. The LBMP at bus i can be written as: Where: = LBMP at bus i in $/MWh = the system marginal price at the Reference Bus = Marginal Losses Component of the LBMP at bus i which is the marginal cost of losses at bus i relative to the Reference Bus = Congestion Component of the LBMP at bus i which is the marginal cost of Congestion at bus i relative to the Reference Bus The Marginal Losses Component of the LBMP at any bus i is calculated using the equation: Where: = delivery factor for bus i to the system Reference Bus and: Where: L = NYCA losses; and = injection at bus i The Congestion Component of the LBMP at bus i is calculated using the equation: Where: K = the set of Constraints; = Shift Factor for bus i on Constraint k in the pre- or post- Contingency case which limits flows across that Constraint (the Shift Factor measures the incremental change in flow on Constraint k, expressed in per unit, for an increment of injection at bus i and a corresponding withdrawal at the Reference Bus); and = the Shadow Price of Constraint k expressed in $/MWh, provided however, this Shadow Price shall not exceed the Transmission Shortage Cost. Substituting the equations for and into the first equation yields: LBMPs will be calculated for the Day-Ahead and the Real-Time Markets. In the Day-Ahead Market, the three components of the LBMP at each location will be calculated from the SCUC results and posted for each of the twenty four (24) hours of the next day. The Real-Time LBMPs will be calculated and posted for each execution of RTD.
LBMP Bus Calculation Method. System marginal costs will be utilized in an ex ante computation to produce Day- Ahead and Real-Time LBMP bus prices using the following equations. Where: The LBMP at bus i can be written as: γi = λR + γLi + γCi γi = LBMP at bus i in $/MWh λR = the system marginal price at the Reference Bus i γ L = Marginal Losses Component of the LBMP at bus i which is the marginal cost of losses at bus i relative to the Reference Bus γ C = Congestion Component of the LBMP at bus i which is the marginal cost of Congestion at bus i relative to the Reference Bus The Marginal Losses Component of the LBMP at any bus i is calculated using the equation: Where: γ L = (DFi - 1) λR i DFi = delivery factor for bus i to the system Reference Bus and: Where: DFi = ( 1 - ∂L ) ∂Pi L = NYCA losses; and Pi = injection at bus i The Congestion Component of the LBMP at bus i is calculated using the equation: c  n  γ = − ∑ i  k∈K GFik μk   , except as noted in Sections 17.1.2.2.1 and 17.1.2.3.1 of this Attachment B Where: K = the set of Constraints; GFik = Shift Factor for bus i on Constraint k in the pre- or post- Contingency case which limits flows across that Constraint (the Shift Factor measures the incremental change in flow on Constraint k, expressed in per unit, for an increment of injection at bus i and a corresponding withdrawal at the Reference Bus); and
LBMP Bus Calculation Method. System marginal costs will be utilized in an ex ante computation to produce Day- Ahead and Real-Time LBMP bus prices using the following equations. Where: The LBMP at bus i can be written as: γi = λR + γLi + γCi γi = LBMP at bus i in $/MWh λR = the system marginal price at the Reference Bus i γ L = Marginal Losses Component of the LBMP at bus i which is the marginal cost of losses at bus i relative to the Reference Bus γ C = Congestion Component of the LBMP at bus i which is the marginal cost of Congestion at bus i relative to the Reference Bus The Marginal Losses Component of the LBMP at any bus i is calculated using the equation: Where: γ L = (DFi - 1) λR i DFi = delivery factor for bus i to the system Reference Bus and: Where: DFi = ( 1 - ∂L ) ∂Pi L = NYCA losses; and Pi = injection at bus i The Congestion Component of the LBMP at bus i is calculated using the equation:

Related to LBMP Bus Calculation Method

  • Calculation methodology No adjustment in the Conversion Price need be made unless the adjustment would require an increase or decrease of at least 1% in the Conversion Price then in effect, provided that any adjustment that would otherwise be required to be made shall be carried forward and taken into account in any subsequent adjustment. Except as stated in this Article VI, the Conversion Rate will not be adjusted for the issuance of Common Stock or any securities convertible into or exchangeable for Common Stock or carrying the right to purchase any of the foregoing. Any adjustments that are made shall be carried forward and taken into account in any subsequent adjustment. All calculations under Article V and Section 6.06 hereof and this Section 6.07 shall be made to the nearest cent or to the nearest 1/10,000th of a share, as the case may be.

  • Balance Computation Method For all dividend-bearing Accounts, dividends are calculated by the average daily balance method which applies a daily periodic rate to the average daily balance for the average daily balance calculation period. The average daily balance is determined by adding the full amount of the principal in Your Account for each day of the period and dividing that figure by the number of days in the period. Accrual on Noncash Deposits. For dividend-bearing Accounts, dividends will begin to accrue on the business day that You deposit noncash items (e.g. checks) into Your Account.

  • Liability Calculation Method Per Claim Unless subject to a fixed dollar copayment, the calculation of Member liability on claims for Out-of-Area Covered Health Care Services processed through the BlueCard Program will be based on the lower of the provider’s billed charges or the negotiated price made available to Blue Shield by the Host Blue. Host Blues determine a negotiated price, which is reflected in the terms of each Host Blue’s health care provider contracts. The negotiated price made available to Blue Shield by the Host Blue may be represented by one of the following:

  • Billing Method 1.5.1 To receive payment for services rendered under this contract, the Contractor shall submit a fully completed invoice for work previously performed to: Minneapolis Public Housing Authority Attention: Accounts Payable, Suite 307 0000 Xxxxxxxxxx Xxx X, Xxxxxxxxxxx, XX 00000 or: xxxxxxxx@xxxxxxx.xxx

  • Payment Methodology The Contractor shall be compensated based on the Service Rates in Attachment for units of service authorized by the Institution in a total amount not to exceed the Contract Maximum Liability established in Section C.1. The Contractor’s compensation shall be contingent upon the satisfactory completion of units of service or project milestones identified in Attachment B. The Contractor shall submit invoices, in form and substance acceptable to the Institution with all of the necessary supporting documentation, prior to any payment. Such invoices shall be submitted for completed units of service or project milestones for the amount stipulated.

  • Measurement method An isolation resistance test instrument is connected between the live parts and the electrical chassis. The isolation resistance is subsequently measured by applying a DC voltage at least half of the working voltage of the high voltage bus. If the system has several voltage ranges (e.g. because of boost converter) in conductively connected circuit and some of the components cannot withstand the working voltage of the entire circuit, the isolation resistance between those components and the electrical chassis can be measured separately by applying at least half of their own working voltage with those components disconnected.

  • Payment Calculation District shall pay Contractor at a rate of $ per . OR District shall pay Contractor as described in attached Exhibit A

  • Test method 3.3.1. The method used shall be that described in Annex 3, paragraph 3.1.

  • Overtime Pay Calculation Overtime shall not be claimed or received for less than fifteen (15) minutes. If overtime amounts to fifteen (15) minutes, or more, it shall be paid for the total period.

  • DATA FOR CALCULATIONS The initial calculations for any payments owing under this Agreement shall be based upon the valuations placed upon the Qualified Property by the Appraisal District in its annual certified appraisal roll submitted to the District pursuant to § 26.01 of the TEXAS TAX CODE in or about July of each year of this Agreement. The certified appraisal roll data shall form the basis from which any and all amounts due under this Agreement are calculated, and the data utilized by the Consultant will be adjusted as necessary to reflect any subsequent adjustments by the Appraisal District to the District’s appraisal roll. Any estimates used by the Consultant to make calculations as required by this Agreement shall be based on the best and most current information available. The Consultant shall from time to time adjust the data utilized to reflect actual amounts, subsequent adjustments by the Appraisal District to the District’s certified appraisal roll, or any other relevant changes to material items such as student counts or tax collections.