Kickplates. 16 gauge stainless steel; 10 inches high: width to equal door width less 2 inches. HARDWARE SCHEDULE Hardware Group A (Typical, rated, single door) 1 Lockset Schlage L9050PD 1-1/2 pair Butt Hinges Xxxxx BB1279 1 Closer Norton 700 Series 1 Stop Quality (332 @ carpet) 1 Smoke Seal Pemko Hardware Group B (Typical, rated, closet/service door)
AutoNDA by SimpleDocs
Kickplates. 16 gauge stainless steel; 10 inches high: width to equal door width less 2 inches. HARDWARE SCHEDULE Hardware Group A (Typical, rated, single door) Hardware Group B (Typical, rated, closet/service door)
Kickplates. 16 gauge stainless steel; 10 inches high: width to equal door width less 2 inches. HARDWARE SCHEDULE Hardware Group A (Typical, rated, single door) Hardware Group B (Typical, rated, closet/service door) 1 Lockset Schlage L9080PD 1-1/2 pair Butt Hinges Xxxxx BB1279 1 Closer Norton 700 Series w/ hold-open 1 Stop Quality (332 @ carpet) 1 Smoke Seal Pemko Hardware Group C (Typical, non-rated door) Hardware Group D (Typical, non-rated, closet/service door) 1 Lockset Schlage L9080PD 1-1/2 pair Butt Hinges Xxxxx BB1279 1 Stop Quality (332 @ carpet) Hardware Group E (Card-access door)
Kickplates. IVES 0000-000-00” x 2” LDW B3E (beveled 3 sides) Provide manufacturer's standard exposed fasteners for door trim units consisting of either machine screws or self-tapping screws. Fabricate edge trim of stainless steel to fit door thickness in standard lengths or to match height of protection plates. Fabricate protection plates not more than 1-1/2 inches less than door width on hinge side and not more than 1/2 inch less than door width on pull side by height indicated. THRESHOLDS Pemko, NGP, Zero SEALS, BOTTOMS & SWEEPS Pemko, Xxxx, NGP Perimeter Seals / Gasketing Pemko 297AV (or Zero / NGP equal) Door Bottoms Pemko 222-APK (or Zero / NGP equal) Door Sweep: Pemko 345AV or Xxxxx 353A At exterior doors provide door bottom and continuous weather-stripping. At fire-resistive-rated door assemblies provide door continuous weather-stripping; in accordance with ASTM E 283 “Test method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen”.
Kickplates. Provide with four beveled edges, 10 and 6 inches high by width less 2 inches on single doors and l inch on pairs of doors, unless otherwise indicated on drawings. Furnish screws to match finish.

Related to Kickplates

  • Programming (a) Pursuant to Section 624 of the Cable Act, the Licensee shall maintain the mix, quality and broad categories of Programming set forth in Exhibit 4, attached hereto and made a part hereof. Pursuant to applicable federal law, all Programming decisions, including the Programming listed in Exhibit 4, attached hereto, shall be at the sole discretion of the Licensee.

  • Media No media releases, public announcements or public disclosures relating to this Agreement or its subject matter, including but not limited to promotional or marketing material, shall be made by the Contractor without the prior written consent of the Client.

  • GRAPHICS Landlord shall provide and install, at Landlord’s cost, all letters or numerals on entrance doors to the Leased Premises. All such letters and numerals shall be in the Building standard graphics, and no others shall be used or permitted on the Leased Premises.

  • Interfaces Bellcore’s GR-446-CORE defines the interface between the administration system and LIDB including specific message formats. (Bellcore’s TR-NWP-000029, Section 10)

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Artwork Licensee must use the Java Logo(s) only in the exact form of approved camera-ready artwork or electronic artwork received from Oracle or Oracle's designee.

  • Hosting 46.7.4.1 At CLEC’s request, SBC-SWBT and SBC-AMERITECH shall perform hosting responsibilities for the provision of billable message data and/or access usage data received from CLEC for distribution to the appropriate billing and/or processing location or for delivery to CLEC of such data via SBC-SWBT’s and SBC-AMERITECH’s internal network or the nationwide CMDS network pursuant to the applicable Appendix HOST, which is/are attached hereto and incorporated herein by reference.

  • Compatibility 1. Any unresolved issue arising from a mutual agreement procedure case otherwise within the scope of the arbitration process provided for in this Article and Articles 25A to 25G shall not be submitted to arbitration if the issue falls within the scope of a case with respect to which an arbitration panel or similar body has previously been set up in accordance with a bilateral or multilateral convention that provides for mandatory binding arbitration of unresolved issues arising from a mutual agreement procedure case.

  • Site Lands or areas indicated in the Contract Documents as being furnished by the Owner upon which the Work is to be performed, including rights-of-way and easements for access thereto, and such other lands furnished by the Owner that are designated for the use of the Contractor. Also referred to as Project Site, Job Site and Premises.

  • Windows a. Front and rear windshield per California Vehicle Code § 26710.

Time is Money Join Law Insider Premium to draft better contracts faster.