Jointing PE Pipe Sample Clauses

Jointing PE Pipe. All dirt or foreign material must be removed from the end of the pipe. If necessary, ends shall be wiped with a clean, dry cloth. Manufacturer's recommendations, ASTM D 2513, ASTM D 3261 and ASTM D2683 must be strictly adhered to during butt or socket fusion procedures, respectively. Plastic pipe and fittings shall be joined by the heat-fusion method in accordance with the written procedures of the pipe manufacturer and using the proper heating device. Heat shall not be applied with a torch or other open flame. Whenever possible all joints should be made above the ground. When it is deemed necessary to make a joint in a trench, the bellhole shall be dug wide and long enough to assure ample slack in the pipe to make a proper joint. The dead end of a plastic main should be terminated with a heat-fused cap. The Contractor shall use a pipe squeezer to control gas and purge air out before capping the dead end of the main.
AutoNDA by SimpleDocs

Related to Jointing PE Pipe

  • Sub-projects 1. The Participating Bank shall make Sub-loans to Beneficiaries and appraise, review, approve, and supervise Sub-projects in accordance with the criteria, conditions and procedures set forth in the Operations Manual, including, inter alia, the following eligibility criteria:

  • Foreign-Owned Companies in Connection with Critical Infrastructure If Texas Government Code, Section 2274.0102(a)(1) (relating to prohibition on contracts with certain foreign-owned companies in connection with critical infrastructure) is applicable to this Contract, pursuant to Government Code Section 2274.0102, Contractor certifies that neither it nor its parent company, nor any affiliate of Contractor or its parent company, is: (1) majority owned or controlled by citizens or governmental entities of China, Iran, North Korea, Russia, or any other country designated by the Governor under Government Code Section 2274.0103, or (2) headquartered in any of those countries.

  • Partnership Working 7.1 Partnerships will be supported by local authorities on four levels between:

  • Sub-loop Elements 2.8.1 Where facilities permit, BellSouth shall offer access to its Unbundled Sub-Loop (USL) elements as specified herein.

  • Partnership The Partnership shall be given days’ notice to purchase the ownership interest under the same terms agreed upon by the potential buyer.

  • Bargaining Unit Roster Upon the signing of this Agreement and monthly thereafter, the Employer shall supply to the Union via a secured method an alphabetical list of all employees covered by this Agreement. The list shall include the name, address, employee identification number, date of hire, rehire date (if applicable), shift, FTE, job classification, department cost center number, unit, hourly rate of pay and monthly gross earnings. Each month, the Employer will provide a list of new hires and addresses, and a list of all employees who have terminated during the month via a secured method. The new hire and termination lists shall include the same data as the monthly employee roster except for monthly gross earnings. The termination list shall include the termination date. Within ninety (90) days of ratification, Swedish Medical Center and SEIU 1199NW will convene a work group including HRIS expert to explore a method for the Employer to provide a list of all employment changes for bargaining unit employees, via a secure site.

  • Project Organization Chart As part of the Mini-Bid, the Authorized User may require the Contractor to develop and submit a proposed project organization chart. The project organization chart should identify all the proposed key personnel of each team component and how the team will be managed. If required, the project organization chart must include both Contractor and State staff roles as identified in the Mini-Bid.

  • Project Organization A summary organization chart showing the interrelationships between Owner, Construction Contractor and Design Professional, and other supporting organizations and permitting review agencies. Detailed charts, one each for Construction Contractor and Design Professional, showing organizational elements participating in the Project shall be included.

  • Operating Agreement You haves received and read a copy of the Company’s Operating Agreement (the “Operating Agreement”) and agree that your execution of this Agreement constitutes your consent to and execution of the Operating Agreement, and, that upon acceptance of this Agreement by the Company, you will become a member of the Company as a holder of Shares. When this Agreement is countersigned by the Company, the Operating Agreement shall be binding upon you as of the closing date.

  • Sub-Loop In locations where SBC-AMERITECH has deployed: (1) Digital Loop Carrier systems and an uninterrupted copper loop is replaced with a fiber segment or shared copper in the distribution section of the loop; (2) Digital Added Main Line (“DAML”) technology to derive multiple voice-grade POTS circuits from a single copper pair; or (3) entirely fiber optic facilities to the end user, SBC-AMERITECH will make the following options available to CLEC:

Time is Money Join Law Insider Premium to draft better contracts faster.