ITS FINAL DESIGN Sample Clauses

ITS FINAL DESIGN. The Engineer shall design and provide details as a part of the State’s Intelligent Transportation System to be managed from locations to be determined. The design elements to be included are:
AutoNDA by SimpleDocs
ITS FINAL DESIGN. The Engineer shall design and provide preparation of plans, specifications and details to modify existing ITS equipment impacted by the roadway/ramp construction. Approximately eleven (11) existing ITS equipment’s impacted by the construction have been identified based on preliminary information. The design elements to be included are:
ITS FINAL DESIGN. The Engineer shall perform the following:
ITS FINAL DESIGN. The Engineer shall design and provide details as a part of the State’s Intelligent Transportation System to be managed from locations to be determined. The design elements to be included are: • Conduit, • Cabling, • Dynamic message signs, • Closed-Circuit Television (CCTV) cameras, • Communications Network Hubs • Traffic Sensor Systems (Bluetooth/RVSD/LED Wrong Way Signs). The Engineer shall develop roadway-based layout sheets depicting the physical location of all ITS devices and supporting equipment. The Engineer shall prepare the design and details including, but not limited to, conduit and cable, support structures and foundations, control equipment, necessary to implement the system. The Engineer shall fully design and prepare communication backbone details to include fiber optic network design including details such as fiber optic cable splicing diagrams. The Engineer shall design all electrical circuits to support all devices proposed for the project and determine availability of electrical power with the appropriate power company at the designed locations.

Related to ITS FINAL DESIGN

  • Final Design A.4.1. Provide OWNER with proposed final construction drawings and detailed opinions of probable total Project construction costs in writing for OWNER' s review, prior to completion of the final Contract Documents, so that any changes that may be necessary in accordance with Project' s budgetary schedule can be made prior to bid.

  • Commencement of Final Design This contract does not obligate the State to proceed with final design for any alternative. On completion of environmental documentation, the State will consider all reasonable alternatives in a fair and objective manner. Notwithstanding anything contained elsewhere in the contract or in any work authorization, the Engineer may not proceed with final design until after all relevant environmental decision documents have been issued.

  • Industrial Designs 5. Patents

  • Final Design Phase A. After acceptance by Owner of the Preliminary Design Phase documents, revised opinion of probable Construction Cost as determined in the Preliminary Design Phase, and/or any other Right of Way plan documents, subject to any Owner-directed modifications or changes in the scope, extent, character, or design requirements of or for the Project, and upon written authorization from Owner, Engineer shall:

  • Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame (MDF) to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (DAMLs), and may have up to 6,000 feet of bridged tap between the End User’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For Loops less than 18,000 feet and with less than 1300 Ohms resistance, the Loop will provide a voice grade transmission channel suitable for Loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point.

  • Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters).

  • Filing Designation The City Department Director will designate each individual who will be providing services to the City pursuant to the Agreement as full disclosure, limited disclosure, or excluded from disclosure, based on an analysis of the services the Consultant will provide. Notwithstanding this designation or anything in the Agreement, the Consultant is ultimately responsible for complying with FPPC regulations and filing requirements. If you have any questions regarding filing requirements, please do not hesitate to contact the City Clerk at (000)000-0000, or the FPPC at 0-000-XXX-XXXX, or (000) 000-0000 *2. Pursuant to the duly adopted City of Chula Vista Conflict of Interest Code, this document shall serve as the written determination of the consultant’s requirement to comply with the disclosure requirements set forth in the Code.

  • Research Design The data generated by excavations at the prehistoric site(s) will be used to examine at least three topics: (1) chronology; (2) technology; and (3) subsistence practices. Insights into changing patterns of community organization may also be granted, as may insights into changes in social organization. The data recovered will then be compared to data from other regional sites.

  • ROADWAY DESIGN MISCELLANEOUS (ROADWAY) The Engineer shall provide the following services:

  • Schematic Design See Section 2, Part 1, Article 2.1.4, Paragraph 2.1.4.2.

Time is Money Join Law Insider Premium to draft better contracts faster.