Interconnection Facilities Cost Sample Clauses

Interconnection Facilities Cost. All costs, excluding One-Time Cost, determined by the Distribution Provider to be associated with the design, engineering, procurement, construction and installation of the Distribution Provider’s Interconnection Facilities. The Interconnection Facilities Cost is provided in Section 15 of this Appendix A.
AutoNDA by SimpleDocs
Interconnection Facilities Cost. All costs, excluding ITCC and One-Time Cost, determined by SCE to be associated with the design, engineering, procurement, construction and installation of the Interconnection Facilities. The Interconnection Facilities Cost is provided in Exhibit B.
Interconnection Facilities Cost. The Developer of the proposed Large Facility shall be responsible for the cost of the facilities needed for its project to reliably interconnect to the New York State Power System, in accordance with the interconnection facilities cost allocation rules set out in Attachment S.
Interconnection Facilities Cost. All costs, excluding One-Time Cost, determined by the Distribution Provider to be associated with the design, engineering, procurement, construction and installation of the Distribution Provider’s Interconnection Facilities. The Interconnection Facilities Cost is provided in Attachment 2 to the GIA. Interconnection Handbook - A handbook, developed by the Distribution Provider and posted on the Distribution Provider’s website or otherwise made available by the Distribution Provider, describing the technical and operational requirements for wholesale generators and loads connected to the Distribution System, as such handbook may be modified or superseded from time to time. In the event of a conflict between the terms of this GIA and the terms of the Distribution Provider’s Interconnection Handbook, the terms in this GIA shall govern. Interconnection Request - The Interconnection Customer's request, in accordance with the Tariff, to interconnect a new Generating Facility, or to increase the capacity of, or make a Material Modification to the operating characteristics of, an existing Generating Facility that is interconnected with the Distribution Provider’s Distribution System. ISO Tariff - The California Independent System Operator Agreement and Tariff, dated March 31, 1997, as it may be modified from time to time, and accepted by FERC. ITCC (Income Tax Component of Contribution) – As defined in Attachment J of the Tariff. Material Modification - A modification that has a material impact on the cost or timing of any Interconnection Request, or any other valid interconnection request to the Distribution Provider or the ISO, with a later queue priority date. NERC – The North American Electric Reliability Corporation or its successor organization. Network Upgrades - Additions, modifications, and upgrades to the Distribution Provider's Transmission System required at or beyond the point at which the Distribution System connects to the Distribution Provider’s Transmission System to accommodate the interconnection of the Generating Facility to the Distribution Provider’s Distribution System. Network Upgrades do not include Distribution Upgrades. Network Upgrades Cost – The Interconnection Customer’s allocated share of all costs, excluding One-Time Cost, determined by the Distribution Provider to be associated with the design, engineering, procurement, construction and installation of the Network Upgrades. The Network Upgrades Cost is provided in Attachment 2 to th...
Interconnection Facilities Cost. All costs, excluding One-Time Cost, determined by the Distribution Provider to be associated with the design, engineering, procurement, construction and installation of the Distribution Provider’s Interconnection Facilities. The Interconnection Facilities Cost is provided in Attachment 2 to the GIA. Interconnection Handbook - A handbook, developed by the Distribution Provider and posted on the Distribution Provider’s website or otherwise made available by the Distribution Provider, describing the technical and operational requirements for wholesale generators and loads connected to the Distribution System, as such handbook may be modified or superseded from time to time. In the event of a conflict between the terms of this GIA and the terms of the Distribution Provider’s Interconnection Handbook, the terms in this GIA shall govern.
Interconnection Facilities Cost. The sum of the Customer-Financed Interconnection Facilities Cost and the SCE-Financed Interconnection Facilities Cost.
Interconnection Facilities Cost. All costs, excluding One-Time Costs, determined by SCE to be associated with the design, engineering, procurement, construction and installation of the SCE-Constructed Interconnection Facilities, and all costs determined by Xxxxxx to be associated with the design, engineering, procurement, construction and installation of the Xxxxxx-Constructed Interconnection Facilities. The Interconnection Facilities Cost is provided in Exhibit B. 4.214.20 Interconnection Facilities In-Service Date: The date upon which the construction of the Interconnection Facilities is complete and such facilities are successfully tested and ready for service. The Interconnection Facilities In-Service Date was February 19, 2008.
AutoNDA by SimpleDocs
Interconnection Facilities Cost. The Distribution Provider’s Existing Interconnection Facilities Cost and the Distribution Provider’s New Interconnection Facilities Cost.
Interconnection Facilities Cost. Any of the Cherry Valley Interconnection Facilities Cost, the Xxxxxxx Hills Interconnection Facilities Cost or the Greenspot Interconnection Facilities Cost.

Related to Interconnection Facilities Cost

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Interconnection Customer Interconnection Facilities Interconnection Customer shall design, procure, construct, install, own and/or control Interconnection Customer Interconnection Facilities described in Appendix A, Interconnection Facilities, Network Upgrades and Distribution Upgrades, at its sole expense.

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • System Protection Facilities The Interconnection Customer shall, at its expense, install, operate and maintain System Protection Facilities as a part of the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities. The Participating TO shall install at the Interconnection Customer's expense any System Protection Facilities that may be required on the Participating TO’s Interconnection Facilities or the Participating TO’s Transmission System as a result of the interconnection of the Large Generating Facility and the Interconnection Customer’s Interconnection Facilities.