Generating Facilities Sample Clauses

Generating Facilities. (1) This sec- tion covers all portions of a generating plant including plant buildings, the generator step-up transformer, and the transmission switchyard at a gener- ating plant. Warehouses and equipment service buildings not associated with generation plants are covered under paragraph (e) of this section. Genera- tion plant buildings must meet the re- quirements of paragraph (e)(1) of this section.
AutoNDA by SimpleDocs
Generating Facilities. All of Seller's generators, together with all protective and other associated equipment and improvements, necessary to produce electrical power at the Project, excluding associated land, land rights, and interests in land.
Generating Facilities. The Member certifies that the following devices constitute the total unit(s) of generating equipment installed and addressed under this Agreement. The Member also warrants that the Facilities have been authorized for connection to the distribution system through the execution of an appropriate Interconnection Agreement. The Member agrees that it will at all times operate its Facilities in accordance with those standards set forth in the Interconnection Agreement between the Member and the Cooperative dated .
Generating Facilities. If a Generating Facility is allocated TP Deliverability in the current Interconnection Study Cycle in an amount less than the amount of Deliverability requested, then the Interconnection Customer must choose one of the following options:
Generating Facilities. 12 4.3. Transmission Requirements ..................................... 12
Generating Facilities. GENCO shall not sell or otherwise assign any interest in any of its generating units (as set forth on Appendix C) except for (i) liens securing bona fide debt or other encumbrances incurred in the ordinary course of business, (ii) capital leases or (iii) sales or assignments made with LIPA's prior written consent, which consent shall be deemed to have been given in respect of any and all easements granted pursuant to either Section 5.3(d) of the Generation Purchase Right Agreement dated as of the date hereof by and between GENCO and LIPA or Paragraph 5 of the Grant of Future Rights attached as Schedule F to the Merger Agreement.
Generating Facilities. Subject to the prior written consent of Buyer, which shall not be unreasonably withheld, Seller may add additional Generating Facilities to this Agreement through an amendment to the Agreement. All contracts between Seller and upstream counterparties must have a delivery term of at least ten (10) years.
AutoNDA by SimpleDocs
Generating Facilities. Pre-energization test, protection review and testing witnessing $10,000 PG&E Primary Revenue Metering $15,000 Primary Service-OH (Per location not including Metering) $15,000 PG&E SCADA Recloser at POI $80,000 XXXX Load Study Scenario 3- None $0 Total -- Interconnection Facility Costs (Subject to Cost-of-Ownership) $ 120,000 ITCC Tax1 TBD In Process 1 Not subject to ITCC (Income Tax Calculation Component) on contribution. ITCC is exempt for wholesale generators that meet the IRS Safe Harbor Provisions. PG&E currently does not require the Interconnection Customer to provide security to cover the potential tax liability on the Interconnection Facilities, Distribution Upgrades, and Network Upgrades per the IRS Safe Harbor Provisions (IRS Notice 88-129). PG&E reserves the right to require, on a nondiscriminatory basis, the Interconnection Customer to provide such security, in a form reasonably acceptable to PG&E as indicated in Article 11 of the SGIA, an amount up to the cost consequences of any current tax liability. Upon request and within sixty (60) Calendar Days’ notice, the Interconnection Customer shall provide PG&E such ITCC security or ITCC payment in the event that Safe Harbor Provisions have not been met, in the form requested by PG&E. Attachment 3 One-line Diagram Depicting the Small Generating Facility, Interconnection Facilities, Metering Equipment, and Upgrades In Process Figure 3-1 One-Line Conceptual Diagram of Xxx Xxxxxx Yard In Process Figure 3-2 Vicinity Map of Xxx Xxxxxx Yard Attachment 4 Milestones In-Service Date: February 5, 2025 Critical milestones and responsibility as agreed to by the Parties: Milestone Date Responsible Party 1 Financial Security Posting Due Date January 22, 2024 Interconnection Customer 2 Initiate Pre-Construction Activities (EGI will request the beginning of estimation and design. Beginning of expenditures against Financial Security.) February 22, 2024 Distribution Provider 3 Submit electronic initial design package (including but not limited to equipment list, 70% final SLD, site map and site plan) January 29, 2024 Interconnection Customer 4 On-site project kick-off meeting February 19, 2024 Distribution Provider & Interconnection Customer 5 Completion of the Interconnection Facilities, Distribution Upgrades, and Network Upgrade facilities January 22, 2025 Distribution Provider & Interconnection Customer 6 In-Service DIate (banck-feed powePr) ro Febcruary 5e, 2025 s Dsistribution Provider & Interconnection Customer...
Generating Facilities. “Generating Facilities” means the solar photovoltaic energy systems installed on Customer’s facilities.
Generating Facilities. The Member certifies that the following devices constitute the total unit(s) of generating equipment installed and addressed under this Agreement.