Gas Measurement Sample Clauses

Gas Measurement. (a) The unit of volume for measurement of Gas delivered hereunder shall be one Mcf at a base temperature of 60 degrees Fahrenheit and at an absolute pressure of 14.73 psia and without adjustment for water vapor content. It is agreed that for the purposes of measurement and computations hereunder, (a) the atmospheric pressure shall be based on the atmospheric pressure determined and used by Downstream Pipelines at the Delivery Point(s) regardless of the atmospheric pressure at which the Gas is measured and (b) all measurements and testing performed hereunder shall all be made by Gatherer in accordance with applicable rules, regulations, and orders.
AutoNDA by SimpleDocs
Gas Measurement. 7.01 The volume of gas produced, saved, and marketed shall be measured according to American Gas Association (AGA) standards and according to Xxxxx’x Law for the measurement of gas under varying pressures with deviations therefrom as provided in Paragraph “e” below, on the measurement basis hereinafter specified and shall be determined as follows:
Gas Measurement. 1. Gas measurement
Gas Measurement. (a) Shipper shall install and own the Primary Measurement Devices located at the Receipt Point(s). Gatherer shall operate the Primary Measurement Devices located at the Receipt Point(s) and shall install, own, operate and maintain the Primary Measurement Devices located at the Delivery Point(s) and any check meters at the Delivery Point(s). Shipper shall have the right, at its sole expense, to install, own, and operate check meters located at the Receipt Point(s); provided, that (i) such equipment is installed so as not to interfere with the Primary Measurement Devices at the Receipt Point(s), and (ii) Shipper shall take steps that are reasonable and customary in the industry to mitigate or prevent any Gas pulsation problems that may interfere with the Primary Measurement Devices at the Receipt Point(s).
Gas Measurement. The quantity and heating value of the Gas delivered by Xxxxxx to Company shall be determined by the transporting Pipeline(s) in the manner provided in its (their) tariff(s) or, for Renewable Gas, by Company in the manner provided in the Service Regulations.
Gas Measurement. (a) The unit of volume for measurement of Gas delivered hereunder shall be one Mcf at a base temperature of 60 degrees Fahrenheit and at a pressure base of 14.73 psia without adjustment for water vapor content. It is agreed that for the purposes of measurement and computations hereunder, (i) the absolute atmospheric (barometric) pressure shall be assumed to be 14.40 psia regardless of the actual elevation or location of the Receipt Point above sea level or of a variation of barometric pressure from time to time and (ii) all measurements and testing performed hereunder shall be made by Gatherer in accordance with applicable rules, regulations, and orders, the terms of this Agreement, and prudent industry standards.
Gas Measurement. Processor shall, at its cost install, operate, and maintain, or shall cause to be installed, operated and maintained, at the Delivery Point suitable measurement equipment to accurately measure the Off-Gas delivered for processing. Processor shall determine the quantity of all Components and the Btus per cubic foot contained in representative samples of Off-Gas at the Delivery Point pursuant to Section B of this Exhibit. The measurement equipment shall consist of electronic flow measurement transmitters measuring differential and static pressure as well as temperature recorders that shall be installed, tested and maintained in accordance with the provisions of this Exhibit. Electronic Flow Measurement (EFM) equipment shall conform to all provisions of API MPMS, Chapter 21. The measuring equipment should include a Xxxxxxx Senior Fitting or equivalent using concentric, square-edged orifice meters per API Chapter 14.3, Natural Gas Fluids Measurement. Volumes shall be measured using a flow computer with real time flow-weighted average temperatures and pressures applied to the volumes in the flow computer to generate a batch end report. A Coriolis type flow meter may be used instead of an orifice type meter if agreed to by both Supplier and Processor. Installation of all electrical and instrumentation facilities shall conform to all provisions of the National Electric Code (NFPA Subpart 70), the American Gas Association “Classification of Gas Utility Areas for Electrical Installation” XF0277, and ANSI/ISA RPI 12.6 “Installation of Intrinsically Safe Instrument System in Class I Hazardous Locations”. All electrical equipment installed in a building containing all or a portion of the Facilities shall be classified and designed for Class I, Division 1 or 2, Group D locations. Any equipment that vents or bleeds natural gas shall be piped in such a way so as to vent or bleed outside any enclosed structure in which it may be installed. The unit of volume for the purpose of measurement of Liquefiable Hydrocarbons, excluding ethylene and propylene, shall be one (1) U.S. liquid gallon of 231 cubic inches, when said liquid has a temperature of sixty degrees Fahrenheit (60oF) and is at the equilibrium vapor pressure of the liquid being measured. Unit of measurement for ethylene and propylene shall be pounds. Unit of measurement for hydrogen shall be Mcf.
AutoNDA by SimpleDocs
Gas Measurement. Landowner shall provide a gas meter properly sized and rated for gas usage rates, pressures and temperatures. The meter shall include a totalizing index, corrected for pressure and temperature, and shall be accurate to within one percent of actual gas flow. Landowner shall submit meter specifications to Hay Exploration, Inc. approval prior to purchase and installation.
Gas Measurement. Gas production volumes from gas xxxxx will be measured using properly calibrated gas meters. Monthly associated gas production volumes from xxxxx completed in oil reservoirs may be calculated by multiplying monthly oil production volumes as reported in the LBU Monthly Report filed with the Department of Oil Properties and estimated GORs. Estimated GORs shall be based on oil and gas production tests from a representative sample of xxxxx determined by XXXX as Field Contractor.
Gas Measurement. The quantity and heating value of the Gas delivered by Xxxxxx to PSNC shall be determined by the transporting Pipeline(s) in the manner provided in its (their) tariff(s) or, for Renewable Gas, by PSNC in the manner provided in its Rules and Regulations.
Time is Money Join Law Insider Premium to draft better contracts faster.