For Underground Utilities Sample Clauses

For Underground Utilities. 1. Open-cut installation for crossings will be permitted only when a highway project is in rough grading stage prior to paving. Generally, on rough grading projects, open-cut will not be permitted in fills of over 10 feet in depth and back filled material must be compacted to maximum density meeting Department requirements.
AutoNDA by SimpleDocs
For Underground Utilities. Open-cut installation for crossings will be permitted only when a highway project is in rough grading stage prior to paving. Generally, on rough grading projects, open-cut will not be permitted in fills of over 10 feet in depth and back filled material must be compacted to maximum density meeting Department requirements. Encasements under an existing freeway must be installed by means of tunneling, jacking, or boring and any voids outside the encasement must be filled with lean concrete grout and the ends of encasements be satisfactorily closed. In cut section, encasement must extend continuously from ditch line to ditch line and in fill section, encasement must extend continuously five feet beyond toe to slopes. Vents for encasement should be extended to the right of way line or as otherwise required by the Department. All pipe encasements as to material and strength shall meet the standards and specifications of the Department. When trenching is carried down cut slopes, excavation must be backfilled to maximum density and the disturbed portion of the slope be stabilized and sodded to the satisfaction of the Department’s Engineer.

Related to For Underground Utilities

  • Underground Utilities Any required ground digging or subsurface work shall be done in accordance with Chapter 556, Florida Statutes. It shall be the responsibility of CONTRACTOR to have all underground utilities located before any work begins (Sunshine State One Call 0-000-000-0000). The repairs of any damaged underground utilities as a result of the work being performed by CONTRACTOR shall be the responsibility of CONTRACTOR. The proper utility company shall be contacted immediately to expedite the repairs, if damage has occurred. CONTRACTOR will notify the COUNTY and provide a written explanation of the incident within two (2) days of the damage to any underground utilities.

  • Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.

  • UNDERGROUND LOCATIONS Prior to the Company commencing any work the Customer must advise the Company of the precise location of all underground services on the site and clearly xxxx the location. The underground mains and services the Customer must identify include, but are not limited to, telephone cables, fibre optic cables, electrical services, gas services, sewer services, pumping services, sewer connections, sewer sludge mains, water mains, irrigations pipes, oil pumping mains and any other services that may be on site. Whilst the Company will take all care to avoid damage to any underground services the Customer agrees to indemnify the Company in respect of all any liability claims, loss, damage, cost and fines as a result of damage to services not precisely located and notified pursuant to this clause.

  • New utilities (i) The Contractor shall allow, subject to the permission from the Authority and such conditions as the Authority may specify, access to, and use of the Site for laying telephone lines, water pipes, electricity lines/ cables or other public utilities. Where such access or use causes any financial loss to the Contractor, it may require the user of the Site to pay compensation or damages as per Applicable Laws. For the avoidance of doubt, it is agreed that use of the Site under this Clause 9.3 shall not in any manner relieve the Contractor of its obligation to construct and maintain the Project Highway in accordance with this Agreement and any damage caused by such use shall be restored forthwith at the cost of the Authority.

  • Services and Utilities Landlord shall furnish all normal services and utilities such as elevator service, lighting replacement for building standard lights, restroom supplies, window washing, janitorial services, heating, ventilation and air conditioning (“HVAC”) maintenance, landscape maintenance, parking lot sweeping, pest control services, and fire alarm monitoring (if installed and required) in a manner that such services are customarily furnished to comparable office buildings in the area. Landlord shall also provide water, sewer, electric, gas and trash removal services to the building as required. Provided that Tenant is not in default hereunder, Landlord agrees to furnish to the Premises at all times , electricity for normal desk top office equipment, .normal copying equipment, technical equipment, and “HVAC” as is reasonably required for the comfortable use and occupancy of the Premises. The normally recognized business hours for the Building are as follows: 7:00 am to 6:00 pm Monday through Friday (except Holidays), and 8:00 am to 1:00 p.m. on Saturdays. If Tenant desires HVAC and/or electricity at any other time, Tenant may override the HVAC and/or electricity system for additional heating, cooling or electricity outside of the normal business hours. Such additional HVAC and/or electricity usage shall be electronically monitored, and Tenant shall pay Landlord’s direct charges therefore on demand. Landlord shall also maintain and keep lighted the common stairs, common entries and restrooms in the Building. Landlord shall not be in default hereunder or be liable for any damages directly or indirectly resulting from, nor shall the Rent be abated by reason of (i) the installation, use or interruption of use of any equipment in connection with the furnishing of any of the foregoing services, (ii) failure to furnish or delay in furnishing any such services where such failure or delay is caused by accident or any condition or event beyond the reasonable control of Landlord, or by the making of necessary repairs or improvements to the Premises, Building or Project, or (iii) the limitation, curtailment or rationing of, or restrictions on, use of water, electricity, gas or any other form of energy serving the Premises, Building or Project, which has been imposed upon the Landlord. Landlord shall not be liable except where Landlord is found to be grossly negligent for a loss of or injury to property or business, however occurring, through or in connection with or incidental to failure to furnish any such services. If Tenant uses heat generating machines or equipment in the Premises which affect the temperature otherwise maintained by the HVAC system, Landlord reserves the right to install supplementary air conditioning units in the Premises and the cost thereof, including the cost of installation, operation and maintenance thereof, shall be paid by Tenant to Landlord upon demand by Landlord. Should Tenant consume water or electric current in excess of that usually furnished or supplied for the use of premises as general office space Landlord may have installed a water meter or electrical current meter in the Premises to measure the amount of water or electric current consumed. The cost of any such meter and its installation, maintenance and repair shall be paid for by the Tenant and Tenant agrees to pay to Landlord promptly upon demand for all such water and electric current consumed as shown by said meters, at the rates charged for such services by the local public utility. If a separate meter is not installed, the excess cost for such water and electric current shall be established by an estimate made by a utility company or an electrical engineer hired jointly by Landlord and Tenant and at Tenant’s expense. Nothing contained in this Section shall restrict Landlord’s right to require at any time separate metering of utilities furnished to the Premises. In the event utilities are separately metered, Tenant shall pay promptly upon demand for all utilities consumed at utility rates charged by the local public utility plus any additional expense incurred by Landlord in keeping account of the utilities so consumed. Tenant shall be responsible for the maintenance and repair of any such meters at its sole cost.

  • COMMON UTILITIES Expenses for serving/supply of common facilities and utilities and all charges incidental thereto.

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins.

  • No Storing Hazardous Articles Not to keep or store any offensive, combustible, obnoxious, hazardous or dangerous articles in the said Apartment, the Common Areas, and the Building.

  • BUILDINGS AND STRUCTURES 1. Repair or retrofit of buildings less than 45 years old.

  • Electrical connections Equipment requiring electrical connections for operation shall either be hard wired to the Authorized User's provided connections or the Contractor shall be responsible for a male electrical union. All connections shall be made by the Contractor and accomplished in accordance with National Electrical Code requirements. Electrically operated equipment shall be available in the following volts and phases: 208 volt 1 or 3 phase, 60 HZ 220 volt 1 or 3 phase, 60 HZ 440 volt 1 or 3 phase, 60 HZ

Time is Money Join Law Insider Premium to draft better contracts faster.