Fire Protection and Safety Sample Clauses

Fire Protection and Safety a. Fire Flow Report sealed by a registered Professional Engineer (NC) demonstrating compliance with Town Standards.
AutoNDA by SimpleDocs
Fire Protection and Safety. 12.6.1 Any fire safety equipment, other than that provided by the Landlord, which is installed by the Tenant must be maintained by the Tenant and is at all times the Tenant’s responsibility.
Fire Protection and Safety. The Agency must have for the Premises an emergency control organisation and procedure that meet AS3745-2002, Emergency Control Organisation and Procedures for Buildings - Standards Australia.
Fire Protection and Safety. Fire Flow Report sealed by a registered Professional Engineer (NC) demonstrating compliance with Town Standards. A Fire Protection plan showing the following: Location of fire hydrants, present and proposed Location of fire department connections to sprinkler/standpipe systems If building has both sprinkler and standpipe, show which FDC feeds which system Road access to fire protection systems Emergency access to the structure on at least two sides Unobstructed 20 ft. emergency access lanes Fencing around construction site with 20 ft. opening swing or slide gates Temporary standpipe locations if building is 40 feet or higher Any areas which are proposed to be inaccessible during construction or demolition Maintain compacted soil/gravel to withstand weight of fire department vehicles at 75,000 pounds vehicle, all weather road standards. Engineering Construction Permit. If any part of a University project lies within a public right-of-way on Town streets, all documents required for an Engineering Construction Permit (ECP) must be submitted as part of the Site Development Permit application process. An ECP must be obtained from the Town prior to start of work on the right-of-way. Energy and Conservation Goals: Permit applications shall include an energy modeling report. Permit applications shall describe how potable water consumption and reclaimed strategies are incorporated into the project Landscape: Plans indicating grading, and limits of construction, existing and proposed tree canopy mix and percent coverage, and other proposed plantings. Plans should also show how the proposed project relates to the overall master plan for Carolina North. identify planting materials, proposed irrigation and maintenance techniques for each type of landscape proposed applications should include any proposed trails, greenways or recreation facilities and connections to adjacent related facilities to be constructed as part of the project and describe the design standards applied to those elements Solid Waste: Describe the solid waste management responsibilities for the project both during the construction phase and after the building is occupied. Public Art: Describe how public art has been incorporated into the project design and planning.
Fire Protection and Safety. (i) The Tenant must undertake fire protection and safety measures in accordance with the requirements of the Department of Human Services Capital Development Guidelines, Series 7 Fire Risk Management September 2001, as amended.
Fire Protection and Safety. The Housing Support Provider must have an emergency control plan and procedure that meet AS3745-2010, Planning for Emergencies and Facilities - Standards Australia for the Premises Category 1.

Related to Fire Protection and Safety

  • Fire Protection Contractor shall take adequate and reasonable precautions to protect the Work against damage by fire and smoke. For example, without limitation, Contractor shall do the following:

  • HEALTH AND SAFETY C8.1 The Contractor shall promptly notify the Authority of any health and safety hazards which may arise in connection with the performance of the Contract. The Authority shall promptly notify the Contractor of any health and safety hazards which may exist or arise at the Authority’s Premises and which may affect the Contractor in the performance of the Contract.

  • Staff Protection A. The District shall protect certificated employees acting within the scope of their employment by purchasing liability insurance in the amount of at least five million dollars ($5,000,000) per occurrence, and the District shall include the certificated employees as named insured under the liability insurance and errors and omissions policy of the school district.

  • Xxxx Protection 22.1With respect to the Parties' rights and obligations under this Framework Agreement, the Parties agree that the Authority is the Data Controller and that the Supplier is the Data Processor.

  • System Protection To prevent compromise of systems which contain DSHS Data or through which that Data passes:

  • TEACHER PROTECTION Section A: Working Conditions Paragraph 1: The Board agrees to str ive continually to provide working condi- tions which meet federal, state and local laws and regulations.

Time is Money Join Law Insider Premium to draft better contracts faster.