Fire Alarm System Sample Clauses

Fire Alarm System. The Sportsplex and Arena are equipped with a Single Stage Fire Alarm System. The Xxxx Park Chalet is equipped with smoke detectors. Once you hear the fire alarm or smoke detector you must prepare for immediate evacuation directly to the outside of the building. Every person that is using the facility in the specific area that you have rented is directly under your responsibility. A coordinated and orderly evacuation is required immediately upon hearing the fire alarm or smoke detector.
AutoNDA by SimpleDocs
Fire Alarm System. Test and Inspect 100% of all fire alarm system components each calendar year to include, but not be limited to, the following:
Fire Alarm System. The base building Fire Alarm System is comprised of Strobes with audible speakers, (not horns) The fire control panels are of Siemens design and Cerberus system 3. Fire alarm devices to have white housings with red lettering. The Landlords alarm contractor must perform any connections to base building fire alarm panels ( expander panels excluded) Light Fixtures:
Fire Alarm System. The Contractor or Electrician shall furnish electrical drawings to Management Office prior to the commencement of construction. These drawings shall include Fire Alarm System (which should be a separate drawing), Riser Diagram and Sequence of Events. The Contractor is responsible for coordinating all work with Management Office. The Building’s Fire Panel contractor, Xxxxxx’x, shall make the final tie-in of all fire devices to the panel on the respective floor(s) at the Contractor’s expense. It is the responsibility of the Contractor to ensure that any devices installed be Building Standard and further, that any strobes/horns moved remain on the same circuit to ensure that the system remains in sync. In the event that the moving of horns/strobes causes the system to be out of sync, it will be the responsibility of the Contractor, as its sole expense, to correct the problem. A work permit must be obtained prior to any work on the fire alarm system from the Town of Watertown. The engineer who designed the mechanical systems shall sign and seal the riser plan and certify, in writing, the completed system to the Town of Watertown prior to the final sign off of the work permit and/or issuance of the Certificate of Occupancy. Also, the electrical contractor shall complete an A433R Form which certifies the correct installation of the fire alarm devices. The signed and sealed plan and A433R Form must be given to the Xxxx Management Office to complete the fire alarm filing and sign-off.
Fire Alarm System. The fire alarm system will continue to operate as is for now, which is to notify City staff of any fire notification for 00 Xxxxx Xxxxxx Xxxxxx. The City agrees that YSS staff should be added as a contact for the fire notifications at 24 and 00 Xxxxx Xxxxxx Xxxxxx, as the buildings are physically attached. YSS will pay one-third the yearly cost for monitoring and testing of the system. This will be xxxx annually. In the future, if the alarm system at the Property needs to be upgraded due to the occupancy status of the building, YSS will be responsible for that upgrade, with a decision to keep the systems connected to be made at that point in time.
Fire Alarm System. When Tenant’s Work interferes with the fire alarm system wiring, connections to this system must be performed by or under the direct supervision of the Building engineers or its designated representatives. The Tenant or its general contractor must contact the Project Manager prior approval to commencing such activity. If system is activated and false alarm is signaled, Tenant will be charged $1000.00 for each event.
Fire Alarm System. Landlord will provide a fire alarm system including a central command center, pull stations, voice communication systems, area and duct detectors (for applicable base building HVAC units larger than 2000 cfm equipment), sprinkler tie in, speakers and strobes at locations and quantities as required by code in core areas of the building. Fire command center will be located in main lobby and will also provide stair pressurization smoke control panel. The tenant, at their cost, shall tie into the system on each floor for required coverage within their respective spaces.
AutoNDA by SimpleDocs
Fire Alarm System. Provide an analog addressable fire alarm system, (Including all infrastructure required to support Tenant’s requirements for horns, strobes and pull stations) with the following characteristics: • Fire alarm system shall be a stand-alone, electrically supervised fire alarm system with smoke detectors in all common area corridors and audible/visual alarms or as required by code; • The central system shall be tied to the security station via telephone lines; • All visual alarms shall be provided per Accessibility codes and NFPA 72 spacing requirements. • Tenant shall be responsible for distributing and installing the fire sprinkler heads, vertically, both up (all concealed space) and down, in a manner consistent with all applicable Laws, at its expense including, but not limited to, all necessary labor, piping, sprinkler heads, pressure and temperature monitors, escutcheons, etc., for the satisfactory operation of a sprinkler system that reaches all areas of the Building, including entrances, alcoves/atrium, mezzanine, decks, and storage/closets. • All equipment, piping installation and testing shall be in accordance with latest applicable Codes, NFPA 13. • All controls for the fire protection system will be connected to a central panel, tied back to a NRTL listed central alarm monitoring station. • Tamper switches shall be provided an all control valves. • Flow switches shall be provided for all zoned mains. • Fire extinguishers shall be located as per NFPA 10. To be included in the Tenant Improvements. • Configurations required for any special first systems needed for technical and kitchen equipment. • Sprinkler piping shall be schedule 40 black steel pipe. • Automatic sprinklers shall be hydraulically designed for ordinary hazard or general office space, storage and loading dock areas, including the following sprinkler head configurations: • Open ceiling - Upright Sprinklers; • Concealed with white escutcheon plates centered in grid; • Wallboard ceilings - Concealed with white covers.
Fire Alarm System. None, unless required by law to complete Landlord’s work contained herein.
Fire Alarm System. (a) Landlord has provided a Class C fire alarm system on each floor connected back to a central fire alarm panel located in the main lobby.