Electrostatic Precipitator Sample Clauses

Electrostatic Precipitator. 1. Concrete
AutoNDA by SimpleDocs
Electrostatic Precipitator. Particulate control for Big Bend Unit No. 4 will be accomplished by the use of a rigid frame electrostatic precipitator. The Precipitator is designed for a 99.7+% particulate removal efficiency and includes the following associated equipment: ductwork and breaching, structural steel, foundations, pilings, hoppers/xxxxxx heat tracing and electrical power and control devices.
Electrostatic Precipitator. The one existing coal-fired boiler is equipped with a new electrostatic precipitator, together with necessary controls, stairways, galleries, enclosures, ductwork and ash removal system. The precipitator is located south of the existing Unit 6 boiler and turbine room at grade. The precipitator is approximately 160’ wide, 47’ long and 36’ high and has an operating weight of 2,387,000 pounds. The Unit 6 boiler was equipped with an electrostatic precipitator (designed for 98% efficiency). The new precipitator was installed in series with the existing electrostatic precipitator. The design combined collection efficiency of the new and existing precipitators is 99.6%.
Electrostatic Precipitator. The one existing coal-fired boiler is equipped with a new electrostatic precipitator, together with necessary controls, stairways, galleries, enclosures, ductwork and ash removal system. The precipitator is located south of the existing Unit 6 boiler and turbine room at grade. The precipitator is approximately 160’ wide, 47’ long and 36’ high and has an operating weight of 2,387,000 pounds. The Unit 6 boiler was equipped with an electrostatic precipitator (designed for 98% efficiency). The new precipitator was installed in series with the existing electrostatic precipitator. The design combined collection efficiency of the new and existing precipitators is 99.6%. Fly Ash Handling and Disposal System. Unit 6 was equipped with a new fly ash removal system consisting of 16 fly ash collecting hoppers with outlet control valves, manifold pipe conveyor, vacuum producing equipment, discharge piping, control panel and pipeline to the existing ash sluice piping.
Electrostatic Precipitator. Electrostatic Precipitator will be provide to two Boiler stack to control particulate matter emission as coal will be used as fuel in boiler. The unique feature of electrostatic precipitator is the separating force that is applied directly to the particles without the necessity of accelerating the entire gas as is done for all other particulate collection devices. This leads to an extremely low pressure loss for the collection of fine particles compared with that in any other type of collector. Principle of Operation  Applying a high-voltage between discharge electrode and collecting electrode causes corona discharge to produce negative ions.  The electrically charged dust is attracted towards the collecting electrodes by an electrical force  The dust accumulated on the collecting electrode is removed and dropped into the hoppers by rapping (i.e impart a vibration or shock to the electrodes) and wet clearing (i.e. water spraying) Advantages of Electrostatic precipitator  Collection of all types of dust, droplets  Collection in both wet and dry conditions  Collection of even sub-micron particles

Related to Electrostatic Precipitator

  • Sampling The Licensee agrees that the Composition is purchased as a “Work Made for Hire” whereby the clearing of any sampled materials is the responsibility of Licensee.

  • Root Cause Analysis Upon Vendor's failure to provide the Services in accordance with the applicable Service Levels (for any reason other than a Force Majeure Event) Vendor will promptly (a) perform a root-cause analysis to identify the cause of such failure, (b) provide Prudential with a report detailing the cause of, and procedure for correcting, such failure, (c) obtain Prudential's written approval of the proposed procedure for correcting such failure, (d) correct such failure in accordance with the approved procedure, (e) provide weekly (or more frequent, if appropriate) reports on the status of the correction efforts, and (f) provide Prudential with assurances satisfactory to Prudential that such failure has been corrected and will not recur.

  • Virus Management Transfer Agent shall maintain a malware protection program designed to deter malware infections, detect the presence of malware within the Transfer Agent environment.

  • Format The data will be provided in the format specified in Specification 2 for Data Escrow (including encryption, signing, etc.) but including only the fields mentioned in the previous section, i.e., the file will only contain Domain and Registrar objects with the fields mentioned above. Registry Operator has the option to provide a full deposit file instead as specified in Specification 2.

  • Protocol No action to coerce or censor or penalize any negotiation participant shall be made or implied by any other member as a result of participation in the negotiation process.

  • Asbestos Any material that contains more than one percent asbestos and is friable or is releasing asbestos fibers into the air above current action levels established by the United States Occupational Safety and Health Administration.

  • Noise The Hirer shall ensure that the minimum of noise is made on arrival and departure, particularly late at night and early in the morning. The Hirer shall, if using sound amplification equipment, make use of any noise limitation device provided at the premises and comply with any other licensing condition for the premises.

  • WINDOW CLEANING Tenant shall not clean, nor require, permit, suffer or allow any window in the Premises to be cleaned from the outside in violation of Section 202 of the Labor Law, or any other Requirement, or of the rules of the Board of Standards and Appeals, or of any other board or body having or asserting jurisdiction.

  • Wash all machine-washable bedding, drapes, and clothing, on the hottest water temperature and dry on the highest heat setting. Items that cannot be washed must be taken to a dry cleaner who MUST be informed of the issue. You must safely discard ALL items that cannot be decontaminated.

Time is Money Join Law Insider Premium to draft better contracts faster.