Driller’s Control Panel Sample Clauses

Driller’s Control Panel. Graphic control panel at Driller’s position showing Subsea functions with controls for the following functions of the BOP stack Marine riser connector: yes/no Yes All annular type Bop’s: yes/no Yes All ram type Bop’s: yes/no Yes Lock for ram type Bop’s : yes/no Yes Wellhead and LMRP connector: yes/no Yes Inner and outer kill and choke line valves: yes/no Yes Low acc. pressure warning: yes/no Yes Low reservoir level warning: yes/no Yes Low rig air pressure warning: yes/no Yes 62 Pressure Regulator for annular: yes/no Yes Flowmeter: yes/no Yes Quantity of pressure gauges: no. 28 Emergency push button for automatic riser disconnection: Yes Other control functions: yes/no Yes Control panel make: NOV-Xxxxxxx Control panel model: 5th generation Mux
AutoNDA by SimpleDocs
Driller’s Control Panel. Graphic control panel at driller’s position showing subsea functions with controls for the following functions of the BOP stack Location. Driller Work Station. Boost Line Control Valve yes/no: YES Marine riser connector yes/no: YES All annular type BOP’s yes/no: YES All ram type BOP’s yes/no: YES Lock for ram type BOPs yes/no: YES Wellhead and LMRP connector yes/no: YES Inner and outer kill and choke line valve: yes/no: YES Low acc. pressure warning yes/no: YES Low reservoir level warning yes/no: YES Low rig air pressure warning yes/no: YES Pressure regulator for annular yes/no: YES Flowmeter yes/no: YES Quantity of pressure gauges no.: 7+ Emergency push button for automatic riser disconnection : YES Other control functions yes/no: YES Control panel make : CAMERON Control panel model : MULTIPLEX
Driller’s Control Panel. Graphic control panel at Driller’s position showing Subsea functions with controls for the following functions of the BOP stack Marine riser connector: Yes/No All annular type Bop’s: Yes/No All ram type Bop’s: Yes/No Lock for ram type Bop’s : Yes/No Wellhead and LMRP connector: Yes/No Inner and outer kill and choke line valves: Yes/No Low acc. pressure warning: Yes/No Low reservoir level warning: Yes/No Low rig air pressure warning: Yes/No Pressure regulator for annular: Yes/No Flowmeter: Yes/No XXXXXXXXXXXX TREATMENT REQUESTED. INFORMATION FOR WHICH CONFIDENTIAL TREATMENT HAS BEEN REQUESTED IS OMITTED AND MARKED WITH “[***]”. AN UNREDACTED VERSION OF THE DOCUMENT HAS ALSO BEEN FURNISHED SEPARATELY TO THE SECURITIES AND EXCHANGE COMMISSION AS REQUIRED BY RULE 24B-2 UNDER THE SECURITIES EXCHANGE ACT OF 1934, AS AMENDED. RIG & EQUIPMENT SPECIFICATIONS Xxxxxx Achiever Deepwater Drillship Quantity of pressure gauges: No.

Related to Driller’s Control Panel

  • Seller’s Conditions The obligations of Seller at the Closing are subject, at the option of Seller, to the satisfaction or waiver at or prior to the Closing of the following conditions precedent:

  • Collateral Locations All of such Grantor’s locations where Collateral is located are listed on Exhibit A. All of said locations are owned by such Grantor except for locations (i) which are leased by the Grantor as lessee and designated in Part VII(b) of Exhibit A and (ii) at which Inventory is held in a public warehouse or is otherwise held by a bailee or on consignment as designated in Part VII(c) of Exhibit A.

  • Building and Improvements Lessor shall obtain and keep in force during the term of this Lease a policy or policies in the name of Lessor, with loss payable to Lessor and to any Lender(s), insuring against loss or damage to the Premises. Such insurance shall be for full replacement cost, as the same shall exist from time to time, or the amount required by any Lender(s), but in no event more than the commercially reasonable and available insurable value thereof if, by reason of the unique nature or age of the improvements involved, such latter amount is less than full replacement cost. Lessee-Owned Alterations and Utility Installations, Trade Fixtures and Lessee's personal property shall be insured by Lessee pursuant to Paragraph 8.4. If the coverage is available and commercially appropriate, Lessor's policy or policies shall insure against all risks of direct physical loss or damage (except the perils of flood and/or earthquake unless required by a Lender), including coverage for any additional costs resulting from debris removal and reasonable amounts of coverage for the enforcement of any ordinance or law regulating the reconstruction or replacement of any undamaged sections of the Building required to be demolished or removed by reason of the enforcement of any building, zoning, safety or land use laws as the result of a covered loss, but not including plate glass insurance. Said policy or policies shall also contain an agreed valuation provision in lieu of any co-insurance clause, waiver of subrogation, and inflation guard protection causing an increase in the annual property insurance coverage amount by a factor of not less than the adjusted U.S. Department of Labor Consumer Price Index for All Urban Consumers for the city nearest to where the Premises are located.

  • Alterations, Additions, and Improvements Subject to the provisions of this Article IV, Lessee may make any alterations, additions, improvements or other changes to the Premises and the Relevant Assets as may be necessary or useful in connection with the operation of the Relevant Assets (collectively, the “Additional Improvements”). If such Additional Improvements require alterations, additions or improvements to the Premises or any of the Shared Access Facilities, Lessee shall notify Lessor in writing in advance and the parties shall negotiate in good faith any increase to the fees paid by Lessee under the Site Services Agreement by Lessee or otherwise provide for reimbursement of any material increase in cost (if any) to Lessor under the Site Services Agreement that results from any modifications to the Premises or the Shared Access Facilities necessary to accommodate the Additional Improvements, or as otherwise mutually agreed by the parties. Any alteration, addition, improvement or other change to the Premises, Relevant Assets or Additional Improvements (and, if agreed by Lessee and Lessor, to the Shared Access Facilities) by Lessee shall be made in a good and workmanlike manner and in accordance with all applicable Laws. The Relevant Assets and all Additional Improvements shall remain the property of Lessee and shall be removed by Lessee within one (1) year after termination of this Lease (provided that such can be removed by Lessee without unreasonable damage or harm to the Premises) or, at Lessee’s option exercisable by notice to Lessor, surrendered to Lessor upon the termination of this Lease. Lessee shall not have the right or power to create or permit any lien of any kind or character on the Premises by reason of repair or construction or other work. In the event any such lien is filed against the Premises, Lessee shall cause such lien to be discharged or bonded within thirty (30) days of the date of filing thereof.

  • Premises Building Project and Common Areas 1.1 Premises, Building, Project and Common Areas.

Time is Money Join Law Insider Premium to draft better contracts faster.