DOORS AND WINDOWS Sample Clauses

DOORS AND WINDOWS. A. Area of Concern: Warped interior doors. Standard: Interior doors should not warp to exceed the National Woodwork Manufacturer’s Association Standards (1/4 inch). Due to dry climate, all doors should be left in closed position to decrease warping. Humidifiers will help decrease warping.
AutoNDA by SimpleDocs
DOORS AND WINDOWS. All doors and windows must remain closed during all functions.
DOORS AND WINDOWS. (a) The unit of measurement shall be number.
DOORS AND WINDOWS. 3.1 Tenant entrance doors should be kept closed at all times in accordance with the fire code.
DOORS AND WINDOWS. 8.1 Doors and frames at the main entrance shall be aluminum entrances or storefront material with thermal break equal to systems designed and engineered by Kawneer Co., Inc. or Tubelite Division, Indal, Inc. Finish is to be dark bronze (M10-C22-A44). All exterior pedestrian door frames and those door frames of adjacent air lock vestibules shall be constructed to accept electric strike hardware (for a biometric access system), and prepped for intrusion alarm system contacts. Loading dock doors and frames shall be prepped for intrusion alarm system contacts. All exterior doors and frames, except at main entrance, shall be custom hollow metal construction provided with heavy duty commercial grade hardware. The main entrance shall be 2 pairs of 36" doors arranged to create an air lock vestibule. Door face sheets shall be commercial quality, roller leveled, cold roll, 16 gauge steel with 18 gauge stiffeners at 6" on center. Provide polystyrene or urethane insulation core filler. All exposed steel surfaces shall be cleaned, bonded and coated with a baked on zinc chromate based prime paint. Frames shall be prefabricated combination buck, frame, and trim type. Mitered joints shall have locking tabs at frame rabbets and backboards. All interior door frames shall be furnished with rubber bumpers. Provide 14 gauge door frames for exterior openings and 16 gauge door frames for interior openings. Reinforce, drill, and tap doors and frames for fully-templated mortised and concealed hardware. Delivery door opening is to be not less than 72" wide. The main entry and airlock vestibule door opening shall allow for a 72" wide clear opening, and all other doors are to be 36" wide. All exterior doors shall be weather-stripped, have a commercial quality aluminum threshold of low profile (beveled) design not to exceed 2” high. Bevel angle shall not exceed 300. Main entry door point shall be protected from rainwater and snow by a canopy. Other exterior doors shall be protected from water by metal flashing over the door heads. Provide an eye level peephole in the delivery door. Provide a xxxx push at the delivery door with a buzzer at the reception counter.
DOORS AND WINDOWS. 08110 Steel Hollow Metal Doors, Frames and Screens 7 08210 Wood Doors 3 08299 Commercial Schedules 4 Commercial Door Schedule, Building A - Administration 11 Commercial Door Schedule, Building B - Multi-faith 1 Commercial Door Schedule, Building C - Cottages C1 thru C6 15 Commercial Door Schedule, Building D - Service / Program. 4 Commercial Door Schedule, Building E - Activities 3 Commercial Window/Screen Schedule, Building A - Administration 2 Commercial Window/Screen Schedule, Building D - Service / Program 1 Commercial Window/Screen Schedule, Building E - Activities 1 08310 Sliding Automatic Doors 8 08330 Coiling Counter Doors 4 08331 Overhead Coiling Doors 5 08360 Sectional Metal Overhead Doors 5 Section No. Title # of Pages 08410 Aluminum Entrances and Screens 8 08520 Aluminum Windows 10 08600 Unit Skylight 2 08710 Door Hardware 15 08730 Power Door Operator 6 08810 Glass and Glazing 8 08920 Glazed Aluminum Curtain Wall 10 DIVISION 9 - FINISHES 09220 Gypsum Plaster 5 09250 Gypsum Board 14 09310 Ceramic Tile 6 09330 Quarry Tile 3 09510 Acoustic Ceilings 4 09520 Wood Ceilings 3 09630 Stone Flooring 6 09640 Wood Flooring 5 09650 Resilient Flooring 4 09655 Linoleum Sheet Flooring 3 09670 Epoxy Seamless Flooring 7 09673 Concrete Floor Sealer 3 09675 Polished Concrete Finish 3 09677 Waterproof Flooring 4 09680 Carpet 6 09840 Acoustical Wall Treatment 4 09900 Painting and Finishing 15
DOORS AND WINDOWS. 1) Window mullion “planning module” to be set at 2’- 6” increments.
AutoNDA by SimpleDocs
DOORS AND WINDOWS. The Contractor shall furnish all materials, labor, services, tools and equipment required for the supply and installation of hollow metal doors, rolling steel doors, windows, glass and glazing, and hardware for the project. Hollow metal doors, frames and components shall be manufactured from hot-dipped galvanized cold rolled steel. Doors shall have insulated cores. The doors and frames shall be shop primed and field finish painted. Doors shall have vision lites, louvers, dampers, etc. as required by their location. The doors and frames shall be furnished and installed per Steel Door Institute (SDI) requirements. Fire rated doors shall comply with NFPA Standard No. 80 and be tested and labeled per UL requirements. All hinged exterior doors shall have automatic door closures. Rolling steel doors and frames shall be manufactured from hot-dipped galvanized cold rolled steel and have insulated interlocking slats. All rolling steel doors shall be motor operated with chain backup. Doors shall be factory primed and field finish painted. Windows shall be manufactured of extruded aluminum frames and ventilator sections. Windows shall be either horizontal sliding type or fixed type depending on location. In general, exterior windows shall be sliding type with screens and storm sash, and interior windows shall be fixed type. Frames shall meet standards of Architectural Aluminum Manufacturer's Association. Hardware shall provide locking capability for all sliding windows. Finish shall be selected by the Owner from the Manufacturer's standard finishes. The main entrance to main building shall be a double doored vestibule with glass doors and walls. Glass and glazing for windows and doors shall comply with applicable ASTM standards, Federal Specifications and Flat Glass Marketing Association. Glass for fire rated applications shall comply with NFPA No. 80 standard for Fire Doors and Windows. Glass for exterior applications shall be tinted insulating glass. Hardware for doors shall comply with applicable sections of Americans with Disabilities Act (ADA), ANSI standards, Builders Hardware Manufacturers Association (BHMA) and SDI. Hardware for fire doors shall comply with NFPA 80 and UL requirements. All hardware shall be installed per manufacturer's recommendations. All locksets shall be master keyed with no more than two master key groups.
DOORS AND WINDOWS. 7.1 ALL Doors and Windows must be left in clean condition and must be locked before vacating the Clubhouse.
DOORS AND WINDOWS. (g) All main entrances to the building shall be emphasized by detailing, changes in materials, and other architectural devices. Such details may include a change in height, roofline or massing, projection of the entrance, or the use of architectural devices such as lintels, columns, porticos, overhangs, corner boards, or fascia boards.
Time is Money Join Law Insider Premium to draft better contracts faster.