DISKING Sample Clauses

DISKING. Disking shall consist of two (2) passes with a disk of sufficient size and weight to uniformly cultivate the ground to a depth of six (6) to ten (10) inches depending upon the time of year. Variance in depth may be permitted, subject to the prior mutual written agreement of CONTRACTOR and CITY. Pursuant to Vacaville Fire Department requirements, one (1)- acre lots or smaller are required to be completely disked; one (1) to five (5) acre lots are to have a thirty (30) foot swath around the property perimeter with a thirty (30) foot swath at one-half (½ ) of parcel; lots that are over five (5) acres require a thirty (30) foot swath of the property perimeter and thirty (30) foot swath at the quarters of parcel and one (1) swath in each direction at center of the parcel. Regardless of lot size/acreage, 100 feet of clearance is required around all structures. Agriculture properties and Hillside residential properties are also required to have a 100’ clearance around structures and improvements. Hillside residential properties may be required to be 100% abated.
AutoNDA by SimpleDocs
DISKING. Disking native prairie or smooth brome is a simple method for improving wildlife habitat. While disking benefits both types of grassland, this practice is generally used to break up solid strands of smooth brome. Disking strips of grassland early in the spring sets back the succession of a grassland community and promotes the growth of broad-leafed plants that are beneficial to wildlife. Disking is also used to maintain and develop firebreaks. Since 1998, approximately 50 acres of smooth brome has been disked by the dam and eight miles of firebreaks have been developed on the area. The firebreaks are a 20-foot wide disc strip. Future plans are to incorporate an additional 20-foot strip beside all present and future firebreaks. When these double strips are established, one strip will be worked and kept clear of vegetation to be used as a firebreak while the other will be worked early in the spring to be used as a broadleaf/foodplot strip. The function of the strips will be alternated yearly. Objective:
DISKING. Weed Abatement by disking shall be performed in such a manner as to completely eliminate all standing weeds. Disking shall be accomplished by using a double throw disc at a depth of 6 inches to place all weeds under soil surface. Where the nature of the soil is such that it is not receptive to the cutting edge of the discs, the areas shall be cross disked to reduce the magnitude of any exposed combustibles only as directed by Park Staff. Where the nature of the soil is such that is not receptive to the cutting edge of the disc being used being used and where the cross disking fails to meet the standards of the County, It shall be the responsibility of the Contractor to provide the proper equipment and hand labor at all times with the tractor operator pulling a disc for purposes of removal of perimeter weeds that are not removed by the disking method. This shall be considered as part of the initial work and no additional compensation will be allowed. Will be considered as included in Contract unit price per ACRE in accordance with these specifications and no additional compensation will be allowed thereafter.
DISKING. Disking shall consist of two (2) passes with a disk of sufficient size and weight to uniformly cultivate the ground to a depth of six (6) to ten (10) inches depending upon the time of year. Variance in depth may be permitted, subject to the prior mutual written agreement of CONTRACTOR and CITY or SUCCESSOR AGENCY, as appropriate. Pursuant to Vacaville Fire Department requirements, one (1)-acre lots or smaller are required to be completely disked; one (1) to five (5) acre lots are to have a thirty (30) foot swath around the property perimeter with a thirty (30) foot swath at one-half (½ ) of parcel; lots that are over five (5) acres require a thirty (30) foot swath of the property perimeter and thirty (30) foot swath at the quarters of parcel and one (1) swath in each direction at center of the parcel. Regardless of lot size/acreage, 100 feet of clearance is required around all structures. Agriculture properties and Hillside residential properties are also required to have a 100’ clearance around structures and improvements. Hillside residential properties may be required to be 100% abated.

Related to DISKING

  • Images If applicable, the CONSULTANT is prohibited from capturing on any visual medium images of any property, logo, student, or employee of the DISTRICT, or any image that represents the DISTRICT without express written consent from the DISTRICT.

  • Devices BNY Mellon will restrict the transfer of Customer Data from its network to mass storage devices. BNY Mellon will use a mobile device management system or equivalent tool when mobile computing is used to provide the services. Applications on such authenticated devices will be housed within an encrypted container and BNY Mellon will maintain the ability to remote wipe the contents of the container.

  • Computer The Contractor shall maintain at its office for its use a computer with, at a minimum, a 1 GHz processor and an internet connection. The Contractor shall maintain individual email accounts for each of its project managers.

  • Device In this agreement, “device” means a physical hardware system) with an internal storage device capable of running the software. A hardware partition or blade is considered to be a device.

  • Encryption The Fund acknowledges and agrees that encryption may not be available for every communication through the System, or for all data. The Fund agrees that Custodian may deactivate any encryption features at any time, without notice or liability to the Fund, for the purpose of maintaining, repairing or troubleshooting the System or the Software.

  • Logging The ISP will require the maintenance of network and application logs as part of BNY Mellon’s security information and event management processes. Logs are retained in accordance with law applicable to BNY Mellon’s provision of the services as well as BNY Mellon’s applicable policies. BNY Mellon uses various tools in conjunction with such logs, which may include behavioral analytics, security monitoring case management, network traffic monitoring and analysis, IP address management and full packet capture.

  • Anti-Doping I understand and agree that the UCI Anti-Doping Rules and U.S. Anti-Doping Agency (USADA) Protocol apply to me. I agree to submit to drug testing. If it is determined I may have committed an anti-doping rule violation, I agree to submit to the results management authority and processes of USADA or the results management authority of the UCI and my national federation. I agree that arbitration is my exclusive remedy under the above rules.

  • OPTICAL ‌ The Employer agrees to provide Optical coverage for active full- time employees in the amount of one hundred twenty-five dollars ($125.00) every twenty-four (24) month period, for the cost of frames, lenses and the fitting of prescription glasses when recommended by a doctor or optometrist. Sunglasses or glasses for cosmetic purposes are not included nor is the cost of eye examinations. While this Appendix is intended to provide an overview of all benefit coverages the insurer’s plan documents will ultimately govern the administration of these benefits. RRSP‌ The Employer agrees to contribute the following amounts to a Registered Retirement Savings Plan for any full-time employee who agrees to contribute an equal amount as follows: Employer Employee Yearly $550.00 $550.00 Such amounts shall be divided by the amount of pay periods for each year and shall be adjusted accordingly. RRSP – Reflect yearly Employer and Employee contribution match.

  • System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.

  • Load Shedding The Distributor may carry out Load Shedding in the following circumstances:

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!