Design One Sample Clauses

Design One. CLEC’s fiber cable (four fibers) and SBC-AMERITECH’s fiber cable (four fibers) are connected at a technically feasible point between CLEC and SBC-AMERITECH locations. This Interconnection point would be at a mutually agreeable location approximately midway between the two. The Parties’ fiber cables would be terminated and then cross connected on a fiber termination panel as discussed below under the Fiber Termination Point options section. Each Party would supply a fiber optic terminal at their respective end. The POI would be at the fiber termination panel at the mid-point meet.
AutoNDA by SimpleDocs
Design One. MCIm and AT&T ILLINOIS shall provide two fibers between their locations. This design may only be considered where existing fibers are available and there is a mutual benefit to both Parties. AT&T ILLINOIS will provide the fibers associated with the “working” side of the system. MCIm will provide the fibers associated with the “protection” side of the system. The Parties will work cooperatively to terminate each other’s fiber in order to provision this joint point-to-point linear chain SONET system. Both Parties will work cooperatively to determine the appropriate technical handoff for purposes of demarcation and fault isolation. The POI will be defined as being at the AT&T ILLINOIS location.
Design One. Sprint’s fiber cable (four fibers) and AT&T 9- STATE’s fiber cable (four fibers) are connected at a Technically Feasible point between Sprint and AT&T 9- STATE locations. This Interconnection point would be at a mutually agreeable location approximately midway between the two. The Parties’ fiber cables would be terminated and then cross connected on a fiber termination panel. Each Party would supply a fiber optic terminal at its respective end. The POI would be at the fiber termination panel at the mid-point Meet Point. (b)
Design One. MCIm and SBC ILLINOIS shall provide two fibers between their locations. This design may only be considered where existing fibers are available and there is a mutual benefit to both Parties. SBC ILLINOIS will provide the fibers associated with the “working” side of the system. MCIm will provide the fibers associated with the “protection” side of the system. The Parties will work cooperatively to terminate each other’s fiber in order to provision this joint point-to-point linear chain SONET system. Both Parties will work cooperatively to determine the appropriate technical handoff for purposes of demarcation and fault isolation. The POI will be defined as being at the SBC ILLINOIS location.
Design One. Cal-Ore’s fiber cable (four, or some integral multiple thereof, fibers) and CenturyTel's fiber cable (four, or some integral multiple thereof, fibers) are connected at an economically and technically feasible point between the Cal-Ore and CenturyTel locations. This Interconnection point would be at a mutually agreeable location.

Related to Design One

  • Design-Builder The person or entity responsible for the proper completion of the activities described in the Contract Documents and who executes the Contract.

  • Design Phase All Basic Services set forth in the Agreement with the exception of Interdisciplinary Document Coordination Review, conducting a Card Trick session, Value-Engineering services, Estimating services. Bidding Phase • All Basic Services set forth in the Agreement. Construction Phase • All Basic Services set forth in the Agreement. Post-Construction • All Basic Services set forth in the Agreement.

  • Design Phase Services § 3.2.1 The Architect shall review the program and other information furnished by the Owner, and shall review laws, codes, and regulations applicable to the Architect’s services.

  • Design Services The Engineer shall perform services during the schematic design phase, the design development phase, the contract documents phase, and the bidding period as hereinafter specified.

  • Design Development Phase INDICATE IN STATEMENT OF WORK “NOT APPLICABLE” IF SECTION IS NOT APPLICABLE

  • Design Development An interim step in the design process. Design Development documents consist of plans, elevations, and other drawings and outline specifications. These documents will fix and illustrate the size and character of the entire project in its essentials as to kinds of materials, type of structure, grade elevations, sidewalks, utilities, roads, parking areas, mechanical and electrical systems, and such other work as may be required.

  • Schematic Design Phase Services § 3.2.1 The Architect shall review the program and other information furnished by the Owner, and shall review laws, codes, and regulations applicable to the Architect’s services.

  • Design Development Phase Services 3.3.1 Based on the Owner’s approval of the Schematic Design Documents, and on the Owner’s authorization of any adjustments in the Project requirements and the budget for the Cost of the Work, the Architect shall prepare Design Development Documents for the Owner’s approval. The Design Development Documents shall illustrate and describe the development of the approved Schematic Design Documents and shall consist of drawings and other documents including plans, sections, elevations, typical construction details, and diagrammatic layouts of building systems to fix and describe the size and character of the Project as to architectural, structural, mechanical and electrical systems, and other appropriate elements. The Design Development Documents shall also include outline specifications that identify major materials and systems and establish, in general, their quality levels.

Time is Money Join Law Insider Premium to draft better contracts faster.