Design Description Sample Clauses

Design Description. Typical floor toilet rooms are provided with 2” x 2” ceramic tile floors and full height ceramic tile walls on wet walls only, painted gypsum drywall ceilings, cove lighting at mirrors and toilets. Base Building toilet rooms to comply with all requirements of the Americans with Disabilities Act.
AutoNDA by SimpleDocs
Design Description. For walkway a clear length of 100.0 m and a breadth of 3.m is required, whereas for the gangways, a clear length of 8 m and breadth of 3 m for each gangway is required. The design of the walkway & gangways are to be carried out considering a load of 600 kg / Cm2. 20% additional load has to be considered for barge movement in floating condition. IS 800 has to be followed for design. The force in each member has to be worked out to retain the combined stress ratio less than unity. Ordinary angle shave to be adopted for wind bracing. Set of adequate size of rollers are to be provided on the connection between pontoons to gangways and between gangways to walkway. The walkway has to be fixed on yoke and yoke base. Adequate safety factor has to be considered to sustain marine environment.
Design Description. 1.1 SUMMARY This Product Specification is for a calcium alginate wound dressing incorporating Acticoat technology for antimicrobial performance. The product is intended for dressing moderately to highly exudative wounds such as decubitus ulcers, diabetic ulcers and venous stasis ulcers. The product in the form of a ribbon would also be suitable for packing deep cavity wounds. Two product sizes will be produced: 4” x 5” and a 0.75” x 12” ribbon.
Design Description. The conceptual design has been made the part of the tender documents. Minimum size of Bus Shelter is 9.30 m x 2.20 m and maximum size is 9.30 m x 3.00
Design Description. Clear length of 30.0 m, inside breadth of 2.2.m and a inside depth of 2.9 m is required. The design of the gangway is to be carried out considering a load of 600 kg / Cm2. 20% additional load has to be considered for barge movement in floating condition. IS 800 has to be followed for gangway design. The force in each member has to be worked out to retain the combined stress ratio less than unity. Ordinary angle shave to be adopted for wind bracing. One set of adequate size of rollers are to be provided on the pontoon end. The gangway has to be fixed on yoke and yoke base. Adequate safety factor has to be consider to sustain marine environment.

Related to Design Description

  • Project Description In two or three brief sentences, provide a concise description of your exhibition. Include the subject matter, type of objects to be included (paintings, sculpture, manuscripts, etc.), those responsible for organizing the exhibition, and catalogue author(s).

  • Aircraft Description The Option Aircraft are described by Boeing Detail Specification D6-38808, Revision E, dated September 15, 1995, as amended and revised pursuant to the Agreement.

  • SERVICE LEVEL DESCRIPTION The Fund Accounting Agreement is hereby amended by deleting the Service Level Description attached thereto and replacing it in its entirety with the Service Level Description attached hereto.

  • Product Description The lead products covered by this Settlement Agreement is limited to following Amazon Identification Number (ASIN) B0BBMRLNV9, with the description, "Lesnow 63-37 Tin Lead Rosin Core Solder Wire for Electrical Soldering 0.8mm Soldering Wire Electronics Solder Content Solder Flux 1.8% (0.8mm, 50g)," which was offered for sale by the Settling Entity on xxxxxx.xxx, hereinafter the “Product” or “Products.”

  • Service Description The Parties will provide Common Channel Signaling (CCS) to one another via Signaling System 7 (SS7) network Interconnection, in accordance with prevailing industry standards. Use of a third party provider of SS7 trunks is permitted.

  • Description of Work (a) that has been omitted or

  • Legal Description The real property is a: (check one) ☐ - Single-Family Home ☐ - Condominium ☐ - Planned Unit Development (PUD) ☐ - Duplex ☐ - Triplex ☐ - Fourplex ☐ - Other: Street Address: Tax Parcel Information (i.e., “Parcel ID” or “Tax Map & Lot”): Other Description:

  • Work Schedule A 4/10 work schedule is four (4) ten hour days in a seven (7) day period, for a total of forty (40) hours per week.

  • Property Description A document prepared as an exhibit for the conveyance of a property interest, reflecting a boundary survey, signed and sealed by a Registered Professional Land Surveyor (RPLS), attached to an acquisition deed as Exhibit A, and consists of the following two (2) parts:

  • Job Description The Employer agrees to draw up job descriptions for all positions for which the Union is bargaining agent. These descriptions shall be presented and discussed with the Union and shall become the recognized job descriptions unless the Union presents written objection with thirty (30) calendar days. If such objection cannot be resolved, the issue may be subject to grievance and arbitration.