Design Conditions Sample Clauses

Design Conditions. Pressurization: The ventilation and exhaust system shall be designed and controlled to provide the necessary quantity of outside air to maintain indoor air quality, to satisfy the combustion air requirements, and exhaust requirements in restrooms, and lunch room areas, while maintaining a positive pressure (0.01” to 0.02” of water column) within the building. Ventilation: Ventilation requirements shall meet the minimum specifications contained in the BOCA Mechanical Code for the occupancy areas. The following values shall be considered a minimum acceptable levels (please note the requirement for individual exhaust fan for the waiting area):
AutoNDA by SimpleDocs
Design Conditions. In general, conductors will be insulated on the basis of a normal maximum conductor temperature of 90 C in 40 C ambient air with a maximum emergency overload temperature of 130 C and a short circuit temperature of 250 C. In areas with higher ambient temperatures, larger conductors will be used or higher temperature rated insulation will be selected. Conductor size and ampacity will be coordinated with circuit protective devices. Cable feeders from medium voltage power equipment will be sized so that a short circuit fault at the terminals of the load will not result in damage to the cable prior to normal operation of fault-interrupting devices. Cables for medium voltage service will be shielded with the shield grounded at both ends, thereby accomplishing the following results:
Design Conditions. Pressurization: The ventilation and exhaust system shall be designed and controlled to provide the necessary quantity of outside air to maintain indoor air quality, to satisfy the combustion air requirements, and exhaust requirements in restrooms, waiting rooms and kitchen areas, while maintaining a positive pressure (0.01 to 0.02 inches of water column) within the building. Ventilation: Ventilation requirements shall meet the minimum specifications contained in the BOCA Mechanical Code for the occupancy areas. The following values shall be considered a minimum acceptable level. General Office 20 cfm/person, or 0.2 cfm/sq. ft. of occupied floor (Which ever is greater) Break room 30 cfm/person Waiting Room 35 cfm/person Outside Air and Recirculation: Not more than 67% of the ventilation air shall be recirculated. The remaining 33% or 5 cfm/person shall be fresh outside air. Exhaust Air: Exhaust air from kitchen areas and restrooms shall meet the minimum specifications contained in the BOCA Mechanical Code for the occupancy areas.
Design Conditions. Nominal Net Equipment Rating (Refer to the Performance Specifications for Equipment Performance Requirements Site Conditions Site Ambient Temp./Relative Humidity 94oF/39.4%RH (Guarantee Conditions) Site Pressure 14.289psia Elevation 785 feet Location Inland Seismic Criteria 1997 UBC, Zone 2A Wind Design 1997 UBC; Exposure C, Importance Factor = 1.00 Basic Wind Speed = 100 mph Fuel Primary Natural Gas Backup Distillate Fuel Oil Gas Fuel Preheating Not Included. Liquid Fuel Preheating Not Included Treatment Not Included Gas Fuel Booster Compressor Not Included. Minimum required gas pressure is 415 psig at customer connection to gas feed module. Maximum operating pressure is 475 psig.
Design Conditions. The heating, ventilating and air conditioning systems will be designed and selected to produce the indoor conditions noted below when the outdoor conditions are as stated:
Design Conditions. 3.1 The Raft River Geothermal Power Plant, Unit 1, is located approximately 40 miles southeast of Burley, Idaho, which is the county seat. Existing assets at the project location include geothermal production xxxxx, injection xxxxx, and monitoring xxxxx. The project location involves an area of approximately two square miles, out of the six square miles of U.S. Geothermal owned and leased land. The entire project is located in Township 00 Xxxxx, Xxxxx 00 Xxxx, Xxxxx Xxxxxxxx, Xxxxxx Xxxxxx, Xxxxx. Facilities by section numbers are provided in the following table Facility Section Standby well RRG-5 22 Power plant unit #1 23
Design Conditions. The design conditions for the pipelines are provided in Table 6.1-1: 62 Raft River Pipeline Contract 05/22/06
AutoNDA by SimpleDocs
Design Conditions. The HVAC for conditioning system shall be capable of maintaining temperatures in the range of 68oF and 78oF, and dehumidify or humidify to maintain a relative humidity in a range between 15% and 50% depending on the season. Ductwork: Fabricate ductwork from a minimum 24 gauge zinc-coated (galvanized) steel, lock-forming quality sheets conforming to ASTM A527. Zinc coating thickness: “Commercial” class G90, except a minimum of 2 oz. per sq. ft. where the metal is exposed to the weather. Ductwork shall be constructed in accordance with SMACNA “HVAC Duct Construction Standards - Metal and Flexible”, First Edition, 1985. Insulate concealed ductwork with Xxxxx Corning all service duct wrap type 100 with FRK vapor barrier facing or foil backing. Insulate exposed ductwork with rigid board insulation over mechanical fasteners. Insulation shall meet UL-181. Duct insulation shall be installed on all ductwork in unconditioned spaces, and outside air ducts between the louver and air handling unit. Flexible ductwork and assemblies shall meet the Class 1 requirements of NFPA 90A and 90B, and labeled by UL with a flame spread of 25 or less and a smoke development rating of 50 or less, in compliance with UL 181. Flexible ducts shall be limited to a maximum length of 5 feet and no section over 2-1/2 feet shall be unsupported. Duct Accessories: Fire dampers shall be installed in all required locations. Diffusers shall be of the following type and sized to meet demand: Type #1 Grillmaster #CB 404, curved blade registers. Key operated opposed blade dampers. Type #2 Grillmaster #RN-PT series round neck perforated diffuser for grid type ceilings. Type #3 24” x 24” eggcrate return diffusers, for grid type ceiling. Temperature Controls: Variations in temperature within each control zone, and between zones, shall not exceed 4oF, with the temperature measured from a reference point one foot inside of any exterior wall to the center of the building. The temperature variation from the floor to a height of 30 inches for any employee work station (either conventional desk or open space modular furniture) shall not exceed 2oF. Testing shall be made when the exterior temperature has reached a daily peak of 80oF or more for two days.
Design Conditions. Any designs (outsourced or in-house), whether created and/or applied to vehicle or product of Client is non-refundable unless the terms of the 1 Year In-House Warranty and/or 5 Year Manufacturer Warranty are deemed applicable for the Client to submit a Warranty Claim. Factors such as visual dissatisfaction, claims of improper color matching, etc. that are representative of the Client’s intended vision are not grounds for refund unless otherwise specified in writing by Xxxxx Xxxxx,
Design Conditions. The design conditions of the waterproofing structure ARMEX BRIDGE belong to producer and are guaranteed by that trough the constitutive materials physical- chemical characteristics (presented in tables no.1 and 2) by quality certificates accompanying the deliveries of final product. Table no. 1 No. Technical characteristics Bituminous membrane ARMEX BRIDGE UM Values according to Technical Sheet Accepted (Romanian) Norms Conditions ind AND 577-2002