Description of the targeted defects Sample Clauses

Description of the targeted defects. The targeted defects in all cases are artificial defects that can be arranged into three groups: side drilled holes (SDH), flat bottom holes (FBH) and notches. The most important characteristics of the defects are ligament, relative position, size (height, diameter) and orientation. The cast mock-ups (1618-B359-B1 and D522-TG) and thin weld (1517-T105EE-2G-GA) have SDH as the artificial defects. The SDH in the mock-up D522-TG are subsurface defects. They possess small diameter, while the sample itself has a coarse grained structure. The 1 Advise Mock-up Inventory list. Available online: xxxxx://xxxxxxxxxxxxxxxxx.xx/sites/Advise/WP1%20deliverables/D1.1%20confidential%20mockup%20inventory/ADVISE_DEL_ D1.1.2_IDMWD_R1(2017-12-22).docx mock-up 1618-B359-B1 has a uniform distribution of grains and additional two FBH’s. The thin weld sample 1517-T105EE-2G-GA has fine grains. The weld repair sample (1774-T248A) has SDH’s and two types of notches: vertical and tilted. Two notches, one from each group has an opening angle of 3.2°. The detailed description of the positions and sizes of the artificial defects can be seen in Tables 6.2–6.5. The technical drawings of the mock-ups are presented in the Annex 8. Table 6.2: Detailed positions and sizes of the artificial defects at mock-up 1618-B359-B1 1618-B359-B1 Dimensions Thickness Width Length Material 90 mm 90 mm 285 mm Inconel 600 Flaw reference SDH10 SDH30 SDH50 SDH70 FBH1 FBH2 Type Side-drilled hole Flat-bottom hole Diameter, d 2 mm 8 mm 4 mm Ligament, z 10 mm 30 mm 50 mm 70 mm 70 mm 70 mm Height, h – 20 mm Offset from FACE2, y – 60 mm 30 mm Offset from FACE1, x 30 mm 60 mm 90 mm 120 mm 240 mm Table 6.3: Detailed positions and sizes of the artificial defects at mock-up D522-TG D522-TG Dimensions Thickness Width Length Material 98 mm 80 mm 598 mm Stainless steel Flaw reference SDH5-1 SDH10-1 SDH15-1 SDH20-1 SDH30-1 Type Side-drilled hole Diameter, d 1 mm Ligament, z 5 mm 10 mm 15 mm 20 mm 30 mm Offset from FACE3, x 70 mm 120 mm 170 mm 220 mm 270 mm Flaw reference SDH5-0.5 SDH10-0.5 SDH15-0.5 SDH20-0.5 SDH30-0.5 Type Side-drilled hole Diameter, d 0.5 mm Ligament, z 5 mm 10 mm 15 mm 20 mm 30 mm Offset from FACE1, x 70 mm 120 mm 170 mm 220 mm 270 mm Table 6.4: Detailed positions and sizes of the artificial defects at mock-up 1517-T105EE-2G 1517-T105EE-2G Dimensions Thickness Width Length Material 32 mm 70 mm 500 mm – Flaw reference SDH10 SDH20 Type Side-drilled hole Diameter, d 1.5 mm Ligament, z 10 mm 20 mm Offset from...
AutoNDA by SimpleDocs

Related to Description of the targeted defects

  • DESCRIPTION OF THE WORKS Employer’s objectives The scope of the request includes the recommended monthly preventative, quarterly and annual maintenance that needs to be conducted to ensure all areas of the airports are lit and compliant. It will include all the other adhoc request (labor rates) where required upon approval by the maintenance manager. The compliance will be based on the following: • Maintenance as per OEM • Organizational guidelines and codes of practice • OHS act 93 – Occupational Health and Safety • ISO 9001 – Quality management • ISO 14001 – Environmental Management • SANS 10142 – The wiring code • ICAO Annex 14 chapter 5. • ACSA Maintenance Procedure D060 024M This scope entails the maintenance and repair of LV systems and all lighting at Costal airports. In brief, maintenance involves servicing, repairs, and testing of lights and LV systems. This involves carrying out maintenance on electrical equipment such as LV DBs, electrical plant, wiring enclosures and luminaires and associated control systems, portable appliances and other specific electrical equipment, in order to minimize downtime, and ensure that the equipment performs at optimal levels and functions to specification at the specified areas. Servicing - performing routine preventive maintenance as prescribed by the original equipment manufacturer (OEM), ACSA’s planned maintenance routines, and applicable legal and design standards. Repairs – responding to breakdowns, callouts and restoring the equipment to safe working conditions on an as and when basis. Advisory – telephonically guiding airport electricians under emergency situations to ensure systems are safely shutdown or returned to service within stringent times. System Performance Test – Testing equipment performance against the OEM, ACSA, and statutory requirements for compliance and return to service purposes. Extent of the works The Contractor will be fully responsible for meeting all requirements in this document regarding the Works. For each piece of equipment, all work will be carried out to standards as required by the Original Equipment Manufacturer (OEM) as well as any applicable governing law and/or regulations. Where OEM standards differ from those required by this document the more stringent requirement shall apply. The Contractor will be fully responsible for obtaining (and keeping up to date with) said requirements. The proposed minimum scheduled maintenance activities can be found in annex H.

  • Description of the Project THIS SHOULD BE NO MORE THAN A TWO PARAGRAPH DESCRIPTION THAT PROVIDES A BACKGROUND OF THE PROBLEM, AS WELL AS HOW THE CONTRACTOR INTENDS TO SOLVE THE PROBLEM. KEEP IN MIND THAT THE CONTRACT SHOULD “STAND ON ITS OWN,” I.E. ANYONE SHOULD BE ABLE TO PICK IT UP AND FIGURE OUT WHAT IS GOING ON.)

  • Description of the Transfer The details of the transfer and of the personal data are specified in Annex B. The parties agree that Annex B may contain confidential business information which they will not disclose to third parties, except as required by law or in response to a competent regulatory or government agency, or as required under clause I(e). The parties may execute additional annexes to cover additional transfers, which will be submitted to the authority where required. Annex B may, in the alternative, be drafted to cover multiple transfers. ANNEX A

  • Completion of Concrete Pours and Emergency Work 24.14.1 Except as provided in this sub-clause an employee shall not work or be required to work in the rain.

  • Description of the transfer(s) The details of the transfer(s), and in particular the categories of personal data that are transferred and the purpose(s) for which they are transferred, are specified in Annex I.B. Docking clause

  • Certification of Meeting or Exceeding Tobacco-Free Workplace Policy Minimum Standards A. Grantee certifies that it has adopted and enforces a Tobacco-Free Workplace Policy that meets or exceeds all of the following minimum standards of:

  • Technical Objections to Grievance No grievance will be defeated or denied by any minor technical objection.

  • CONSTRUCTION OF THE BUS TERMINAL 12.1 Obligations prior to commencement of construction Prior to commencement of Construction Works, the Concessionaire shall:

  • Application of General Conditions These General Conditions set forth the terms and conditions generally applicable to the Development Grant Agreement to the extent and subject to any modifications set forth in such agreement.”

  • GEOGRAPHIC AREA AND SECTOR SPECIFIC ALLOWANCES, CONDITIONS AND EXCEPTIONS The following allowances and conditions shall apply where relevant: Where the company does work which falls under the following headings, the company agrees to pay and observe the relevant respective conditions and/or exceptions set out below in each case.

Time is Money Join Law Insider Premium to draft better contracts faster.