Complexity Factor Sample Clauses

Complexity Factor. The complexity factor for centres is determined in the following manner: • The average staffing attendance figure from the Preschool Staffing Exercise multiplied by a factor of three. • The total enrolment figures for Term 4. • The number of Aboriginal children enrolled in the centre for Term 4 multiplied by a factor of two. • The number of children from non-English speaking background enrolled in the centre for Term 4. • The number of occasional care sessions multiplied by a factor of four. • The notional school card indicator multiplied by a factor of three. The sum of all these figures gives the total complexity factor.
AutoNDA by SimpleDocs
Complexity Factor. Figure 5-5F presents a description for the various levels on the complexity of work. R Value Complexity of Work CPFF = 0.0 DLM = 0.0 Low complexity projects that involve such work as project surveys, routine drafting functions, minor simple span bridges, small rural projects, project reports, and simple environmental assessments. CPFF = 0.035 DLM = 0.003 Complex jobs that involve such work as small urban projects, freeway interchanges, projects on new alignment, freeways, multi- span continuous bridges, complex environmental assessments, and design reports. CPFF = 0.070 DLM = 0.008 Very complex work that involves such work as multi-level interchanges, movable bridges, complex major bridges, major urban freeways, complex design reports, environmental impact statements, and major engineering studies requiring special expertise. COMPLEXITY FACTOR 5-5.11 Agreement Processing‌ Once the LPA and the consultant have agreed on scope, terms, and compensation, the engineering agreement shall be submitted to the District BLRS for review.
Complexity Factor. Figure 5-5E presents a description for the various levels on the complexity of work. R Value Complexity of Work CPFF = 0.0 DLM = 0.0 Low complexity projects that involve such work as project surveys, routine drafting functions, minor simple span bridges, small rural projects, project reports, and simple environmental assessments. CPFF = 0.035 DLM = 0.003 Complex jobs that involve such work as small urban projects, freeway interchanges, projects on new alignment, freeways, multi- span continuous bridges, complex environmental assessments, and design reports. CPFF = 0.070 DLM = 0.008 Very complex work that involves such work as multi-level interchanges, movable bridges, complex major bridges, major urban freeways, complex design reports, environmental impact statements, and major engineering studies requiring special expertise. COMPLEXITY FACTOR Figure 5-5E

Related to Complexity Factor

  • Other Factors The Employer may provide for additional formal and informal evaluations as it shall determine to be necessary for the proper conduct of the educational program and the utilization of its employees. The evaluation opinions of the Employer shall not be subject to the Grievance Procedure if the procedures herein set forth have been followed.

  • Power Factor The Power Producer shall maintain the Power Factor as per the prevailing GERC regulations and as may be stipulated / specified by GETCO from time to time. The Power Producer shall provide suitable protection devices, so that the Electric Generators could be isolated automatically when grid supply fails. Connectivity criteria like short circuit level (for switchgear), neutral Grounding, fault clearance time, current unbalance (including negative and zero sequence currents), limit of harmonics etc. shall be as per Grid Code.

  • Mitigating Factors The Contractor had a Trafficking in Persons compliance plan or an awareness program at the time of the violation, was in compliance with the plan, and has taken appropriate remedial actions for the violation, that may include reparation to victims for such violations.

  • Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.

  • ADJUSTMENT FACTORS The Contractor will perform any or all Tasks in the Construction Task Catalog for the Unit Price appearing therein multiplied by the following Adjustment Factors. See the General Terms and Conditions for additional information.

  • Performance Factors (a) Each party will notify the other party of the existence of a Performance Factor, as soon as reasonably possible after the party becomes aware of the Performance Factor. The Notice will:

  • SECONDARY FACTORS (a) The extent of control which, by agreement, COUNTY may exercise over the details of the work is slight rather than substantial; (b) CONTRACTOR is engaged in a distinct occupation or business; (c) In the locality, the work to be done by CONTRACTOR is usually done by a specialist without supervision, rather than under the direction of an employer; (d) The skill required in the particular occupation is substantial rather than slight; (e) The CONTRACTOR rather than the COUNTY supplies the instrumentalities, tools and work place; The length of time for which CONTRACTOR is engaged is of limited duration rather than indefinite; (g) The method of payment of CONTRACTOR is by the job rather than by the time; (h) The work is part of a special or permissive activity, program, or project, rather than part of the regular business of COUNTY; (i) CONTRACTOR and COUNTY believe they are creating an independent contractor relationship rather than an employee relationship; and The COUNTY conducts public business. It is recognized that it is not necessary that all secondary factors support creation of an independent contractor relationship, but rather that overall there are significant secondary factors which indicate that CONTRACTOR is an independent contractor. By their signatures to this Agreement, each of the undersigned certifies that it is his or her considered judgment that the CONTRACTOR engaged under this Agreement is in fact an independent contractor.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point Xxxxxx. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • CLASS SIZE/STAFFING LEVELS The board will make every effort to limit FDK/Grade 1 split grades where feasible. APPENDIX A – RETIREMENT GRATUITIES

  • Characteristics of the level (a) A person employed as a Social and community services employee level 6 will operate under limited direction from senior employees or management and undertake a range of functions for which operational policies, practices and guidelines may need to be developed.

Time is Money Join Law Insider Premium to draft better contracts faster.