Cladding Sample Clauses

Cladding. The external cladding to all levels(except for doors and windows) must be at least 80% brick, brick veneer or other applied texture coated material such as rendered finish, granosite or similar finish approved by the Seller.
AutoNDA by SimpleDocs
Cladding. ▪ Roof and side cladding with min. 0.47mm & 0.50mm respectively of Pre-Painted Galvanized Iron (PPGI) with zinc coating not less than 120 gm/m2 OR permanent colour coated Galvalume sheet with suitable profile and min. strength of 550 Mpa. Colour of the sheet shall be preferably light Gray and all structural members shall be dark blue colour. Translucent (Poly Carbonate) sheet/ FRP sheet of min. 1.5mm thick of approved make shall be provided for alternative bays on roof top (10% of the sheeting area) for natural lighting. Both roof and side cladding are to be made “Water Tight”. Roof slope shall be 1:10. ▪ Purlins for wall & roof cladding shall be ‘Z or C’ shape made-up with pressed steel. ▪ Gutters: 26G metallic Xxxxx gutter including all fixing accessories like clamps, drop end etc.
Cladding. ▪ Roof and side cladding with min. 0.47mm & 0.50mm respectively of Pre-Painted Galvanized Iron (PPGI) with zinc coating not less than 120 gm/m2 OR permanent colour coated Galvalume sheet with suitable profile and min. strength of 550 Mpa. Colour of the sheet shall be preferably light Gray and all structural members shall be dark blue colour. Translucent (Poly Carbonate) sheet/ FRP sheet of min. 1.5mm thick of approved make shall be provided for alternative bays on roof top (10% of the sheeting area) for natural lighting. Both roof and side cladding are to be made “Water Tight”. Roof slope shall be 1:10. ▪ Purlins for wall & roof cladding shall be ‘Z or C’ shape made-up with pressed steel. ▪ Gutters: 26G metallic Xxxxx gutter including all fixing accessories like clamps, drop end etc. ▪ Down Take Pipes: Sufficient HDPE Rain Water down Pipe shall be provided and properly connected with gutters all around the sheds.
Cladding. The proposed massing and cladding systems are two primary design drivers that together miss an opportunity for superior design. The building form consists of conjoined and extruded masses pushed to different heights to align with the required height and bulk floor plate requirements. The cladding is homogenous from top to bottom, except the ground level, and consists of a seemingly conventional curtainwall system with vertical fins and horizontal markers every five floors. The result is a set of masses without clear definition wrapped in an overly consistent skin. The project should define itself or its parts with a clear formal logic. Some examples of this might include: as a tower with a base; a continuously shaped form that modulates between a horizontal base and slender tower; or as a set of elements that have an identifiable relationship either through a formal operation (rotation, offset, intersection, etc.) or through detailing (reveals, corners, framing of smaller elements, etc.). As a partner to the massing system, the cladding might introduce another type or shift to support a change in form, adjust a consistent system in density, material, or rhythm, or modulate through a medium-scale articulation. The cladding currently does not respond or reflect the façade orientation, height, and does so minimally at the ground level. As cladding is such a dominant feature of high-rise design, designers should consider creative materials choices, textures, and configurations to respond to the architectural concept, enclosure system requirements, and code demands. The ground and top of the building should be exceptional and identifiable from pedestrian and remote distances respectively. The base and upper base should have a more refined, detailed, and identifiable presence that brings the scale of the building to the street. The project should add operable windows where possible, particularly in the base to promote active interfaces with the street. The entries should be hierarchically pronounced with canopies or other architectural-scaled elements. Ground Floor The ground floor will need significant reconfiguration in both program and architectural character to satisfying active use goals. The office lobby sides that dominate the overall interface at the Xxxxxx and Xxxxx Street sides are currently longer than the 40’ or 25% maximum permitted by city planning code. Reducing the lobby interface at the street would allow for additional active retail use with op...
Cladding. The steel and copper interface must have a metallurgical bond achieved through a high heat and pressure bonding process. Established process for porosity-free material.
Cladding. 2.1 The Tenant hereby confirms to the Developer (but without reducing the Developer's responsibility for the proper physical implementation thereof and design development thereof) that the specification of the bomb blast elements of the cladding system forming part of the Base Building Specification has been approved by the Tenant as suitable for its purposes
Cladding. N310.1 corrugated acoustic panel, thickness: 125mm complete with polyester powder coating all round m2 *** *** *** N310.2 Flashing m *** *** *** N310.3 U channel m *** *** *** SIMPLE BUILDING WORKS INCIDENTAL TO CIVIL ENGINEERING WORKS Windows, Doors and Glazing Aluminium Z321 window or vision panel complete with all necessary frame, ironmonger and glazing, to suit clear opening of size 1m high m *** *** *** Z323 doors, acoustic, complete with all necessary frame and ironmonger, to suit clear opening of size: 1500 x 2150 mm nr *** *** *** ELECTRICAL INSTALLATION Main Distribution System BA410 sub-main distribution equipment sum *** *** *** -------------------------------------------------------------------------------------------------- TOTAL OF COST CENTRE P2 TO COST CENTRE SUMMARY *** ---------- *** Certain information on this page has been omitted and filed separately with the Securities and Exchange Commission. Confidential treatment has been requested with respect to the omitted portions. [STAMP] 9 August 2002 Page P2/5 Contract No. LDB-201 FORM OF TENDER SCHEDULE OF RATES APPENDIX 2 - PRICING DOCUMENT CONFORMING TENDER COST CENTRE P - NOISE BARRIERS
AutoNDA by SimpleDocs