Choke Manifold Sample Clauses

Choke Manifold. 1. Contractor shall furnish one actuated valve and one manual valve on the choke line outlet. Valves to be furnished with geothermal trim, including Stellite gates. Actuator to be suitable for high temperature geothermal service.
AutoNDA by SimpleDocs
Choke Manifold. ● Prepare to function test several valves. ● Prepare to flush lines ● Prepare to open a valve for inspection. ● Prepare to open both remote chokes. ● Provide the following documents: - Wall thickness reports. - Pressure test reports. - Calibration of the pressure gauges.
Choke Manifold. (for instrumentation, see H.3) Make: Minimum ID: in Maximum WP: psi H2S service: Yes/No Quantity of fixed chokes: No. Make: Model: Size (ID): in Quantity of adjustable chokes: No. Make: Model: Size (ID): in
Choke Manifold. Cameron 3-1/16" - 15,000 psi WP with two (2) Cameron hydraulically adjustable choke, two (2) manual chokes.
Choke Manifold. Characteristics: 3-1/16” × 10,000 psi, H2S resistant Choke (Manual): (2xmin.) 2-9/16” × 10000 psi H2S resistant.
Choke Manifold. (for instrumentation, see H.3) Make: RB PipeTech Ltd. Minimum ID: in 3 Maximum WP: psi 15,000 H2S service: yes/no Yes Quantity of fixed chokes: no. N/A Make: N/A Model: N/A Size (ID): in N/A Quantity of adjustable chokes: no. 2 Make: Masterflo Model: P25 Size (ID): in 1.45 Quantity of power chokes: no. 2 Make: Masterflo Model: P25 Size (ID): in 1.45 Power choke remote control panel: yes/no Yes Make: Hitec Location Drillers Doghouse Glycol injection: yes/no Yes
Choke Manifold. (for Instrumentation, see H.3) Make: CAMERON Minimum ID: in 2 1/16” Maximum WP: psi 15,000 psi H2S service: yes/no Yes Quantity of fixed chokes: no. 0 Make: N/A Model: N/A Size (ID): in N/A Quantity of adjustable chokes: no. (4) 2 of which are auto Make: Cameron Model: 15 kpsi Manual Choke Size (ID): in 3 1/16” Quantity of power chokes: no. 2 X AUTO CHOKES Make: Cameron Model: 15 kpsi Hydraulic Choke Size (ID): in 3 1/16” Power choke remote control panel: yes/no Yes Make: HDI Location DCC (driller’s control center) Glycol injection: yes/no Yes
AutoNDA by SimpleDocs

Related to Choke Manifold

  • Cockpit (a) Fairing panels shall be free of stains and cracks, will be clean secure and repainted as necessary;

  • Loading RPMG shall schedule the loading and shipping of all outbound corn oil purchased hereunder, but all labor and equipment necessary to load trucks and rail cars and other associated costs shall be supplied and borne by Producer without charge to RPMG. Producer shall handle the corn oil in a good and workmanlike manner in accordance with RPMG’s written requirements and normal industry practice. Producer shall maintain the truck and rail loading facilities in safe operating condition in accordance with normal industry standards and shall visually inspect all trucks and rail cars to assure (i) cleanliness so as to avoid contamination, and (ii) that such trucks and railcars are in a condition suitable for transporting the corn oil. RPMG and RPMG’s agents shall have adequate access to the Ethanol Facility to load Producer’s corn oil on an industry standard basis that allows RPMG to economically market Producer’s corn oil. RPMG’s employees shall follow all reasonable safety rules and procedures promulgated by Producer and provided to RPMG reasonably in advance and in writing. Producer shall supply product description tags, certificates of analysis, bills of lading and/or material safety data sheets that are applicable to all shipments. In the event that Producer fails to provide the labor, equipment and facilities necessary to meet RPMG’s loading schedule, Producer shall be responsible for all costs and expenses, including without limitation actual demurrage and wait time, incurred by RPMG resulting from or arising in connection with Producer’s failure to do so.

  • Speed (a) The Contract Price shall not be affected or changed by reason of the trial speed (as determined according to the SPECIFICATIONS being less than the guaranteed speed, if such variation is not more than Two-Tenths (2/10) of One (1) knot.

  • Fuel Upon redelivery of the Aircraft to Lessor, an adjustment will be made in respect of fuel on board on the Previous Delivery Date and the Expiry Date at the price then prevailing at the Redelivery Location.

  • Plant An electrical generating alternative energy resource facility developed by Producer for which IID shall provide transmission service, as specified in Exhibit(s) II, Transmission Service, and in any subsequent Plant Amendments.

  • Wash all machine-washable bedding, drapes, and clothing, on the hottest water temperature and dry on the highest heat setting. Items that cannot be washed must be taken to a dry cleaner who MUST be informed of the issue. You must safely discard ALL items that cannot be decontaminated.

  • Delivery Point Once Manufacture of the Products has been completed, Contractor shall be responsible for delivering the Finished Goods FCA, (as defined in Incoterms (2000) published by the International Chamber of Commerce) and to a freight forwarder specified by Company in its Order, or otherwise approved by Company. “Delivery Point” as used in this Agreement shall mean the specific time and location that the Product is delivered to the shipper specified on the Order.

  • Floor Loading Floor loading capacity shall be within building design capacity. Tenant may exceed floor loading capacity with Landlord’s consent, at Landlord’s sole discretion and must, at Tenant’s sole cost and expense, reinforce the floor as required for such excess loading.

  • Delivery Points The measurement of and tests for quality of Shipper's Gas redelivered at the Delivery Points shall be governed by and determined in accordance with the requirements of the receiving pipeline at each Delivery Point.

  • Underground Tanks If underground or other storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any underground storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks.