Ceiling System Sample Clauses

Ceiling System. Ceiling systems must conform to fire, acoustics, maintenance and light reflection requirements. Gypsum board ceiling suspension systems shall have 16 gauge, 1 – ½” main channels with 25 gauge 7/8” furring channels. Acoustic panel ceilings shall comply with ASTM E1374 classifications and metal suspension systems with applicable ASTM C635 requirements. Suspend lighting fixtures independent of ceiling. Provide edge moldings, trim and acoustical sealant as required. Exposed face shall be white enamel. Grid spacing shall be 24” x 48”. Lay in panels shall have an NRC range of .55 to .65, STC range of 35-39, LR-1, flame spread of 0-25 (ASTM E84) and nominally 5/8” thick. All lay in panels shall be identical in type and cleanliness. All lay in ceiling panels shall be new. Minimum ceiling height shall be not less than 9’-0” nominal except in small rooms or limited areas, defined as mechanical or janitorial rooms, which may be 8’-0”. Provide unfaced sound attenuation blankets over ceiling systems to meet room to room sound transmission requirements. Provide painted, 5/8” gypsum board ceilings in airlock entry vestibules and for the security room. Provide means of access to ceiling systems for maintenance of equipment or repair of system.
AutoNDA by SimpleDocs
Ceiling System. 2 x 2 USG DX26 heavy duty grid with 2 x 2 Tegular USG Eclipse #76775 or equal (or match existing). Install in accordance with U.B.C. STD. NO. 47-18. Carpet and Title (Floor Coverings): ----------------------------------- See Exhibit 2-B (Tenant Specifications) Window Coverings - Exterior Windowline: --------------------------------------- Off-white Louverdrape verticals (with p-21) 3-1/2" vanes, or equal. Window Coverings - Interior Windows: ------------------------------------ See Exhibit 2-B (Tenant Specifications). Paint and Finishes: ------------------- See Exhibit 2-B (Tenant Specifications).
Ceiling System a. Ceiling Tile:
Ceiling System. Tenant's ceiling construction (in excess of that supplied by Landlord per paragraph 3 above) and installation of acoustical ceiling tile.
Ceiling System. Tenant requires the Building’s ceiling finish height to be a minimum of nine (9) feet, and the Landlord to install a drop, T-bar ceiling system, with new ceiling tile (Xxxxxxxxx Cirrus or equivalent) stockpiled in the floor for installation by Tenant.
Ceiling System. The installation of a 2 ft. x 2 ft. modular ceiling grid system similar to a Xxxx Fine-line. Tenant may remove the ceiling grid system.
Ceiling System. The Landlord will provide a suspended T-Bar ceiling system with 2' x 4' lay-in acoustical tile for tenant ceiling on a "single plane basis". Ceiling height to be 10 feet. Any additional cost of installing the ceiling system caused by partition walls or other interior Tenant improvements shall be borne by Tenant.
AutoNDA by SimpleDocs
Ceiling System 

Related to Ceiling System

  • Ceilings 13.1 Lambdaboard ceilings, minimum 25mm thick with a width of 1220mm x 1800mm, skimmed with Plascon EZ Joint and EZ Skim system.

  • Ceiling Company and its subcontractors will not affix, attach, or suspend any lighting fixtures, signs, or other fixtures or devices of any kind or nature from the ceiling above any of the Premises without the prior written approval of Authority.

  • Building Systems The term “Building Systems” shall mean collectively the mechanical, electrical, plumbing, sanitary, sprinkler, heating, ventilation and air conditioning, security, life safety, elevator and other service systems or facilities of the Building and the finished ceiling and Building standard lighting fixtures in the Leased Premises, that are excluding any Premises Fixtures.

  • Walls 12 Developer shall provide rustication patterns on all walls, except drainage headwalls, in Aesthetic 13 Area 3 in accordance with Exhibit L2.24 of the LAADCR. The final designs shall resemble these 14 simulations.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Roof Any leaks or evidence of moisture? Yes No Unknown Type of Roof: Age Comments: Is there any existing fire retardant treated plywood? Yes No Unknown Comments:

  • Floor Loading Floor loading capacity shall be within building design capacity. Tenant may exceed floor loading capacity with Landlord’s consent, at Landlord’s sole discretion and must, at Tenant’s sole cost and expense, reinforce the floor as required for such excess loading.

  • Windows a. Front and rear windshield per California Vehicle Code § 26710.

  • Elevators Landlord shall provide passenger elevator service during normal business hours to Tenant in common with Landlord and all other tenants. Landlord shall provide limited passenger service at other times, except in case of an emergency.

  • Base Building “Base Building” means the Building Structure and Mechanical Systems, collectively, defined as follows: