Applicable test procedures Sample Clauses

Applicable test procedures. 6.1. For parts of Class 1: Over pressure test Annex 15, para. 4. External leakage Annex 15, para. 5. High temperature Annex 15, para. 6. Low temperature Annex 15, para. 7. Seat leakage Annex 15, para. 8. Endurance (Number of cycles shall be 50,000 cycles) Annex 15, para. 9. LPG compatibility Annex 15, para. 11.** Corrosion resistance Annex 15, para. 12.* Resistance to dry heat Annex 15, para. 13.** Ozone ageing Annex 15, para. 14.** Creep Annex 15, para. 15.** Temperature cycle Annex 15, para. 16.**
AutoNDA by SimpleDocs
Applicable test procedures. 6.1. For parts of Classes 0 and 1: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.1 Resistance to dry heat Annex 16, para. 13.** Ozone ageing Annex 16, para. 14.**
Applicable test procedures. 6.1. Fuel pump mounted inside the container: LPG compatibility Annex 15, para. 11 **/
Applicable test procedures. 3.1. LNG fuel pump mounted inside the tank: LNG compatibility test Annex 5D Resistance to dry heat Annex 5F Ozone ageing Annex 5G Low temperature test Annex 5P 3.2. LNG fuel pump mounted outside the tank: Overpressure or strength Annex 5A External leakage Annex 5B LNG compatibility Annex 5D Corrosion resistance Annex 5E Resistance to dry heat Annex 5F Ozone ageing Annex 5G Temperature cycle Annex 5H Vibration resistance Annex 5N Low temperature test Annex 5P Annex 5 Test procedures
Applicable test procedures. In Table 5.1 below, the applicable test procedures dependent on the classification are shown. Table 5.1 Test Class 0 Class 1 Class 2 Class 3 Class 4 Class 5 Class 6 Annex Overpressure or strength X X X X O X X 5A External leakage X X X X O X X 5B Durability tests A A A A O A A 5L CNG/LNG compatibility A A A A A A A 5D Corrosion resistance X X X X X A X 5E Burst/destructive tests X O O O O A X 5M Temperature cycle A A A A O A A 5H Vibration resistance A A A A O A A 5N Operating temperatures X X X X X X X 5O LNG low temperature O O O O O X O 5P X = Applicable O = Not applicable A = As applicable Remarks:
Applicable test procedures. In table 5.1 below the applicable test procedures dependent on the classification are shown. Table 5.1 Test Class 0 Class 1 Class 2 Class 3 Class 4 Paragraph Overpressure or strength X X X X O 5A External leakage X X X X O 5B CNG compatibility A A A A A 5D Burst/destructive tests X O O O O 5M Temperature cycle A A A A O 5H Pressure cycle X O O O O 5I Vibration resistance A A A A O 5N Operating temperatures X X X X X 5O X = Applicable O = Not applicable A = As applicable Remarks:
Applicable test procedures. 6.1. For parts of Class 1: Over pressure test Annex 15, para. 4 External leakage Annex 15, para. 5 High temperature Annex 15, para. 6 Low temperature Annex 15, para. 7 Seat leakage Annex 15, para. 8 Endurance Annex 15, para. 9 LPG compatibility Annex 15, para. 11 **/ Corrosion resistance Annex 15, para. 12 */ Resistance to dry heat Annex 15, para. 13 Ozone ageing Annex 15, para. 14 **/ Creep Annex 15, para. 15 **/ Temperature cycle Annex 15, para. 16 **/ E/ECE/324 Rev.1/Add.66/Rev.1 Regulation No. 67 page 58 Annex 6
AutoNDA by SimpleDocs
Applicable test procedures. 3.6.1. For fuel rails of Class 0 and 1: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11. ** Corrosion resistance Annex 16, para. 12. * Resistance to dry heat Annex 16, para. 13. ** Ozone ageing Annex 16, para. 14. ** Creep Annex 16, para. 15. ** Temperature cycle Annex 16, para. 16. **
Applicable test procedures. In Table 1 the applicable test procedures dependent on the classification are shown. Table 1 Test Class 0 Class 1 Class 2(A) Class 3 Paragraph Overpressure x x x x 4. External leakage x x x x 5. High temperature x x x x 6. Low temperature x x x x 7. Seat leakage x x x 8. Endurance / Functional tests x x x 9. Operational test x x 10. LPG compatibility x x x x 11. Corrosion resistance x x x x 12. Resistance to dry heat x x x 13. Ozone ageing x x x 14. Creep x x x 15. Temperature cycle x x x 16. Compatibility with heat exchange fluid x x 17.
Applicable test procedures. Over pressure test External leakage High temperature Low temperature LPG compatibility Corrosion resistance Resistance to dry heat Ozone ageing Creep Temperature cycle Annex 15, para. 4 Annex 15, para. 5 Annex 15, para. 6 Annex 15, para. 7 Annex 15, para. 11 **/ Annex 15, para. 12 */ Annex 15, para. 13 **/ Annex 15, para. 14 **/ Annex 15, para. 15 **/ Annex 15, para. 16 **/
Time is Money Join Law Insider Premium to draft better contracts faster.