Ground fault definition

Ground fault means an accidental electrical grounding of an electrical conductor.
Ground fault means any undesirable current path from a current-carrying conductor to ground.
Ground fault means an acci- aentai electrical grounding o f an elec­ trical conductor.

Examples of Ground fault in a sentence

  • Ground fault Circuit Interrupter (GFCI) protection must be installed in accordance with the National Electrical Code (NEC) and current Virginia Occupational Safety and Health Agency (VOSH) regulations.

  • Ground fault interrupter shall be consist of a differential current transformer, solid state sensing circuitry and a circuit interrupter switch.

  • Ground fault current interrupting breakers, shunt trip breakers, lighting control breakers (including accessories to switch line currents), or other accessory devices or functions shall be provided where shown on the drawings.

  • Ground fault neutralizer grounding Synchronous generators shall not be permitted to connect to utility secondary network systems without the acceptance of the utility.

  • Ground fault circuit interrupter (GFCI) protection and arc-fault circuit interrupter (AFCI) protection where required.

  • Ground fault interrupters are required in outlets located in the garage, kitchen, bath, and powder room along with all exterior outlets.

  • Ground fault circuit interrupter receptacles and breakers shall be tested at least once in each month the spa is operating.

  • Ground fault protection shall be set at minimum settings for both current and time during construction.

  • Ground fault interrupter shall consist of a differential current transformer, solid state sensing circuitry and a circuit interrupter switch.

  • As per para 10.4.1 of CEAM 2008, Desk Review is the first phase of the audit programme.


More Definitions of Ground fault

Ground fault means a current carrying conductor (either positive or negative) is in contact with earth ground. Referencing Figure 13, we see by the arrow a MidNite 63A GFP breaker. This is a double stacked breaker with a normal 150V, 63A breaker on the left and a 0.5A shunt-trip breaker on the right, wired at the top to the battery minus and at the bottom to earth ground. The shunt- trip breaker detects voltage between negative and ground; if a voltage is present, the shunt-trip will open causing the 63A breaker on the left to open, thus removing the positive PV connection between the PV array and the charge controller.