WIRES AND CABLES Clause Samples

The "Wires and Cables" clause defines the standards and requirements for the types, installation, and quality of electrical wires and cables used in a project. It typically specifies the acceptable materials, insulation ratings, and compliance with relevant codes or regulations, and may require that all wiring be properly labeled and protected against damage. By setting these guidelines, the clause ensures electrical safety, system reliability, and regulatory compliance, thereby reducing the risk of electrical hazards and future maintenance issues.
POPULAR SAMPLE Copied 2 times
WIRES AND CABLES. A. All wire and cable furnished and installed under this contract shall be new and of the best quality and of size, type and numbers shown on the plans or required. Conductors shall be soft annealed copper conforming to conductivity and in all other respects, to the requirements of the ASTM. Unless otherwise stated, wire shall be rated at 600 volts. Wire sizes indicated are for copper conductors. Feeder wire shall be aluminum. B. All feeders and motor wiring should be type THW, THHN or THWN. Branch circuit wiring shall be type TW, THW or THHN. No wire smaller than #14 shall be used, unless otherwise noted, and all #8 and larger shall be stranded. C. No wires shall be drawn into conduit until all work of a nature which may cause injury is completed. Mechanical wire pulling apparatus may be used only on conductors larger than #4 AWG, provided sufficient lubricating compound is used and conduit is so arranged as to hold possibility or injuring insulation to an absolute minimum. No grease, oil or lubricants other than approved wire pulling compounds shall be used to facilitate the pulling in of wires. Feeders shall be run their entire length in continuos pieces, without joints or splices, in so far as practical. D. Wire shall meet or exceed IPECA-NEMA applicable requirements. E. For conductors #8 AWG and larger, cable connector shall be of "color keyed compression type". Smaller conductors shall use "Scotchlock" brand by Minnesota Mining & Manufacturing Company (3M), Ideal Industries, Inc., or equivalent.
WIRES AND CABLES. 2.2.1. Provide wires and cables in accordance with applicable requirements of NFPA 70 and UL for the type of insulation, jacket, and conductor specified or indicated. Do not use wires and cables manufactured more than 12 months prior to date of delivery to site.
WIRES AND CABLES. Prior approval is required from the OHTM for all additional cabling and wiring for lights/sound. Wires/cables must run along the floor of the stage or house and be taped in
WIRES AND CABLES. In general, the wires and cables included under this Section shall include, but not be limited to, the following:
WIRES AND CABLES