{"component": "clause", "props": {"groups": [{"snippet_links": [{"key": "transmission-lines", "type": "definition", "offset": [32, 50]}], "size": 10, "samples": [{"hash": "1CsgTqRAKZB", "uri": "/contracts/1CsgTqRAKZB#transformers", "label": "New England Power Pool Agreement (New England Power Co)", "score": 19.0, "published": true}, {"hash": "jpUCCT2Z4a", "uri": "/contracts/jpUCCT2Z4a#transformers", "label": "New England Power Pool Agreement (North Atlantic Energy Corp /Nh)", "score": 18.0, "published": true}, {"hash": "ipDfA39K0dI", "uri": "/contracts/ipDfA39K0dI#transformers", "label": "New England Power Pool Agreement (United Illuminating Co)", "score": 18.0, "published": true}], "snippet": "All transformers connecting PTF transmission lines shall be included in the analysis.", "hash": "36eeaa7e03c327ae4d6c2c4915b53b9c", "id": 1}, {"snippet_links": [{"key": "on-the-premises", "type": "definition", "offset": [51, 66]}, {"key": "polychlorinated-biphenyls", "type": "clause", "offset": [82, 107]}, {"key": "to-seller", "type": "definition", "offset": [124, 133]}], "size": 5, "samples": [{"hash": "fQQC2ag6pFv", "uri": "/contracts/fQQC2ag6pFv#transformers", "label": "Membership Interest Purchase Agreement (Comstock Inc.)", "score": 34.5085557837, "published": true}, {"hash": "dovz6iU6sqG", "uri": "/contracts/dovz6iU6sqG#transformers", "label": "Membership Interest Purchase Agreement (AMERICAN BATTERY TECHNOLOGY Co)", "score": 34.5003422313, "published": true}, {"hash": "6Ak5ep5B6ta", "uri": "/contracts/6Ak5ep5B6ta#transformers", "label": "Membership Interest Purchase Agreement (AMERICAN BATTERY TECHNOLOGY Co)", "score": 34.3689253936, "published": true}], "snippet": "Seller has never installed or used any transformer on the Premises that contained polychlorinated biphenyls\u2019 compounds, and to Seller\u2019s knowledge, there are no and never have been any polychlorinated biphenyls\u2019 compounds stored or used on the Premises.", "hash": "8d5035c3cbb0bd82561d83080108888d", "id": 2}, {"snippet_links": [{"key": "ambient-temperature", "type": "clause", "offset": [178, 197]}, {"key": "zone-4", "type": "definition", "offset": [230, 236]}, {"key": "acceptable-manufacturers", "type": "clause", "offset": [254, 278]}, {"key": "general-electric", "type": "clause", "offset": [288, 304]}], "size": 5, "samples": [{"hash": "4sukgf5jYaG", "uri": "/contracts/4sukgf5jYaG#transformers", "label": "Office Lease (PDF Solutions Inc)", "score": 21.0, "published": true}], "snippet": "a. Transformers shall be UL listed and suitable for the application- NEMA 1 or 3 R.\nb. Transformers shall be 480V (primary) \u2013 20by/120V (secondary), rated for 80 C rise above an ambient temperature of 40 C.\nc. Support for seismic zone 4 requirements.\nd. Acceptable manufacturers shall be General Electric, C\u2587\u2587\u2587\u2587\u2587-\u2587\u2587\u2587\u2587\u2587\u2587, Siemens, Square D, or Westinghouse.", "hash": "a54902191cbf2029c9092828c721efde", "id": 3}, {"snippet_links": [{"key": "to-serve", "type": "definition", "offset": [65, 73]}, {"key": "maximum-demand", "type": "definition", "offset": [85, 99]}, {"key": "the-sub", "type": "clause", "offset": [103, 110]}, {"key": "research-facilities", "type": "definition", "offset": [160, 179]}, {"key": "by-the-university", "type": "clause", "offset": [216, 233]}, {"key": "design-team", "type": "definition", "offset": [238, 249]}, {"key": "full-capacity", "type": "clause", "offset": [332, 345]}, {"key": "generally-the", "type": "clause", "offset": [391, 404]}, {"key": "three-phase", "type": "definition", "offset": [535, 546]}, {"key": "to-provide", "type": "definition", "offset": [611, 621]}, {"key": "wire-service", "type": "clause", "offset": [647, 659]}, {"key": "task-lighting", "type": "clause", "offset": [680, 693]}, {"key": "convenience-outlets", "type": "clause", "offset": [695, 714]}, {"key": "specific-equipment", "type": "definition", "offset": [716, 734]}, {"key": "determining-factors", "type": "clause", "offset": [770, 789]}, {"key": "cost-of", "type": "definition", "offset": [832, 839]}, {"key": "length-of", "type": "clause", "offset": [854, 863]}, {"key": "addition-of", "type": "clause", "offset": [891, 902]}], "size": 4, "samples": [{"hash": "HPgVttF7h0", "uri": "/contracts/HPgVttF7h0#transformers", "label": "Owner's Design Guidelines Agreement", "score": 35.1887643262, "published": true}, {"hash": "4UieTOXf65", "uri": "/contracts/4UieTOXf65#transformers", "label": "Owner's Design Guidelines Agreement", "score": 32.7639253609, "published": true}, {"hash": "891PiKrEm5Z", "uri": "/contracts/891PiKrEm5Z#transformers", "label": "Owner\u2019s Design Guidelines Agreement", "score": 25.8295687885, "published": true}], "snippet": "a. Each transformer in a double ended sub-station shall be sized to serve 75% of the maximum demand on the sub-station. In critical loads such as hospitals and research facilities or where determined to be necessary by the University and design team, this may be increased to 100%.\nb. Where feeders are arranged in a looped system, full capacity feed-through capability will be required.\nc. Generally the first transformation shall be to 277/480 volts, 3 phase, 4 wire. 4160 volts, 3 phase, 3 wire may be required for large motors.\nd. Three phase dry type transformers shall be installed at strategic locations to provide 120/208 volt, 3 phase, 4 wire service to incandescent and task lighting, convenience outlets, specific equipment loads and small motors. One of the determining factors of the transformer locations shall be the cost of the increased length of branch circuits versus the addition of transformers/panels.", "hash": "44471804a8fd3fa0f3a87027ca0fde64", "id": 4}, {"snippet_links": [{"key": "provisions-for", "type": "clause", "offset": [201, 215]}, {"key": "circuit-breakers", "type": "clause", "offset": [224, 240]}, {"key": "square-foot", "type": "definition", "offset": [293, 304]}, {"key": "light-fixtures", "type": "definition", "offset": [350, 364]}, {"key": "located-in", "type": "definition", "offset": [440, 450]}, {"key": "wiring-devices", "type": "clause", "offset": [492, 506]}], "size": 3, "samples": [{"hash": "gazVcVGX9kh", "uri": "/contracts/gazVcVGX9kh#transformers", "label": "Lease Agreement (Unisphere Networks Inc)", "score": 18.0, "published": true}, {"hash": "5KLHArigHDW", "uri": "/contracts/5KLHArigHDW#transformers", "label": "Lease Agreement (Unisphere Solutions Inc)", "score": 18.0, "published": true}], "snippet": "Dry-type K20 rated transformers will be provided for 120/208 volt panels. 16A-\u2587\u2587 \u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587l be 480/277 volt, 3-phase, 4-wire and 120/208 volt, 3-phase, 4-wire with 200% neutrals with provisions for bolt in circuit breakers. Panelboards will be sized for the HVAC 6 watt\u2587 \u2587\u2587\u2587 square foot and 2 watt\u2587 \u2587\u2587\u2587 square foot for the 277 volt light fixtures and 6 watt\u2587 \u2587\u2587\u2587 square foot at for 120/208 volt power. Panelboards will be located in electrical closets on each floor. 16A-08 WIRING DEVICES, OUTLETS AND SWITCHES", "hash": "bd97dfac4f79397d0b857706f17f61b8", "id": 5}, {"snippet_links": [{"key": "equipment-supplied", "type": "clause", "offset": [106, 124]}], "size": 2, "samples": [{"hash": "gVp9SdXqQdk", "uri": "/contracts/gVp9SdXqQdk#transformers", "label": "Architectural and Engineering Services Agreement", "score": 32.7278984144, "published": true}, {"hash": "bpu4zQe0eee", "uri": "/contracts/bpu4zQe0eee#transformers", "label": "Architectural and Engineering Services Agreement", "score": 32.3668292417, "published": true}], "snippet": "Label that includes tag designation indicated on Drawings for the transformer, feeder, and panelboards or equipment supplied by the secondary.", "hash": "ab2ab5d73c3f76de13def84cfea14b14", "id": 6}, {"snippet_links": [], "size": 2, "samples": [{"hash": "bbiHzovsxfk", "uri": "/contracts/bbiHzovsxfk#transformers", "label": "Operations & Maintenance Agreement", "score": 33.8053982918, "published": true}, {"hash": "7pdTXHUMfGz", "uri": "/contracts/7pdTXHUMfGz#transformers", "label": "Operations & Maintenance Agreement", "score": 24.6988364134, "published": true}], "snippet": "DC sub-system (e.g., combiner boxes or re-combiner boxes) 6.7. AC systems", "hash": "99ea9f2cc1aac235cb646d3e66a35d3b", "id": 7}, {"snippet_links": [{"key": "in-general", "type": "clause", "offset": [0, 10]}, {"key": "normal-operation", "type": "definition", "offset": [184, 200]}, {"key": "in-order-to", "type": "clause", "offset": [422, 433]}, {"key": "status-of", "type": "clause", "offset": [572, 581]}, {"key": "technical-data", "type": "definition", "offset": [833, 847]}, {"key": "other-elements", "type": "clause", "offset": [1026, 1040]}], "size": 2, "samples": [{"hash": "jkee9P8g2WK", "uri": "/contracts/jkee9P8g2WK#transformers", "label": "Operation and Maintenance Agreement (Abengoa Yield LTD)", "score": 21.1587953457, "published": true}, {"hash": "iRxTLqBoXRF", "uri": "/contracts/iRxTLqBoXRF#transformers", "label": "Operation and Maintenance Agreement (Abengoa Yield LTD)", "score": 21.1587953457, "published": true}], "snippet": "In general they must be in good preservation condition, without oxidations or corrosions in the oil drum and tank, deformations in cooling blades. \u2022 It will be checked that during its normal operation there is no abnormal vibrations or noises, excess temperatures, relevant leaks of coolant and oil level under the minimum at 20\u00baC, or very higher. \u2022 If the transformer has wheels, it will be checked that they are blocked in order to avoid its movement. The anchor must be fixed to the support or rail by threaded or welded parts, or wheels must be turned. \u2022 Preservation status of main and secondary insulators, without having cracks, breakages or excess dirt. The correct fixation to the flap will be checked. \u2022 The plate will be properly fixed to the transformer drum and, if possible, visible from the cell outside since all its technical data must be readable. \u2022 The external insulation of power cables, control and signalization must not show aging, relevant tears, damages or provoke mechanic strains in insulators and other elements. \u2022 Oil analysis will be carried out by authorized laboratories and its cleaning and replacement will be performed as necessary.", "hash": "76cd3d4511495b4d02b622a3d32f768a", "id": 8}, {"snippet_links": [{"key": "to-the-extent", "type": "clause", "offset": [0, 13]}, {"key": "of-landlord", "type": "clause", "offset": [14, 25]}, {"key": "the-land", "type": "clause", "offset": [78, 86]}, {"key": "the-property", "type": "clause", "offset": [91, 103]}, {"key": "to-transmit", "type": "definition", "offset": [204, 215]}, {"key": "the-system", "type": "definition", "offset": [241, 251]}, {"key": "the-equipment", "type": "definition", "offset": [266, 279]}, {"key": "exhibit-b", "type": "definition", "offset": [331, 340]}, {"key": "incorporated-herein-by-reference", "type": "clause", "offset": [361, 393]}], "size": 2, "samples": [{"hash": "tmge1sqPuk", "uri": "/contracts/tmge1sqPuk#transformers", "label": "Land Lease Agreement", "score": 23.9377138946, "published": true}, {"hash": "2nRUWYszGwt", "uri": "/contracts/2nRUWYszGwt#transformers", "label": "Land Lease Agreement", "score": 23.9281314168, "published": true}], "snippet": "To the extent of Landlord's rights therein, any electric transformer in or on the Land, on the Property, or used by or connected to the Land (collectively the \"Transformer\") for Tenant to connect thereto to transmit electricity generated by the System to the Grid. (The Equipment and Transformer are more particularly described on Exhibit B attached hereto and incorporated herein by reference.)", "hash": "c13ca114f29152d5756f21d4d961949f", "id": 9}, {"snippet_links": [{"key": "the-management", "type": "clause", "offset": [89, 103]}, {"key": "in-order-to", "type": "clause", "offset": [131, 142]}, {"key": "provision-of", "type": "clause", "offset": [365, 377]}, {"key": "circuit-breakers", "type": "clause", "offset": [394, 410]}, {"key": "distribution-of", "type": "clause", "offset": [415, 430]}, {"key": "in-addition-to-the", "type": "clause", "offset": [447, 465]}, {"key": "service-outlets", "type": "clause", "offset": [496, 511]}, {"key": "common-area", "type": "clause", "offset": [523, 534]}, {"key": "the-condominium", "type": "clause", "offset": [538, 553]}], "size": 2, "samples": [{"hash": "lfTur0FaXeM", "uri": "/contracts/lfTur0FaXeM#transformers", "label": "Private Instrument of Built to Suit Property Lease Agreement (Netshoes (Cayman) Ltd.)", "score": 26.2032854209, "published": true}, {"hash": "jtlUqBpAqPD", "uri": "/contracts/jtlUqBpAqPD#transformers", "label": "Private Instrument of Built to Suit Property Lease Agreement (Netshoes (Cayman) Ltd.)", "score": 25.9541409993, "published": true}], "snippet": "Kva three-phase transformer shall be used to the warehouse, and 1 150 kVA transformer to the management, frequency 60Hz, NB1 95kV, In order to protect transformers against overvoltage surges, three 12 kV (10ka) grounded polymeric lightning arresters shall be used, duly interconnected and grounded. There will be a meter of the Concessionary for the warehouse with provision of One QGBT with 6 circuit breakers for distribution of the main loads, in addition to the lighting circuit breakers and service outlets and to the common area of the Condominium.", "hash": "f0f386767a0b3acbdbf4503a8ae0d0fe", "id": 10}], "next_curs": "ClUST2oVc35sYXdpbnNpZGVyY29udHJhY3RzcjELEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2IhV0cmFuc2Zvcm1lcnMjMDAwMDAwMGEMogECZW4YACAA", "clause": {"title": "Transformers", "children": [["routine-tests", "Routine Tests"], ["type-tests", "Type Tests"], ["participant-designations", "Participant Designations"], ["pool-size", "Pool Size"], ["timing-of-calculations", "Timing of Calculations"]], "size": 73, "parents": [["miscellaneous", "MISCELLANEOUS"], ["representations-and-warranties-of-seller", "Representations and Warranties of Seller"], ["project-partnering", "PROJECT PARTNERING"], ["general-requirements", "GENERAL REQUIREMENTS"], ["entire-agreement", "Entire Agreement"]], "id": "transformers", "related": [["insulation", "Insulation", "Insulation"], ["generators", "Generators", "Generators"], ["electrical", "Electrical", "Electrical"], ["welding", "Welding", "Welding"], ["plumbing", "Plumbing", "Plumbing"]], "related_snippets": [], "updated": "2025-07-07T16:38:45+00:00"}, "json": true, "cursor": ""}}