{"component": "clause", "props": {"groups": [{"snippet_links": [{"key": "not-limited", "type": "clause", "offset": [37, 48]}], "snippet": "Temporary structures, including, but not limited to, tents and inflatable objects are prohibited.", "size": 7, "samples": [{"hash": "kGQAdkNl7U7", "uri": "/contracts/kGQAdkNl7U7#temporary-structures", "label": "Rental Agreement", "score": 31.9997577667, "published": true}, {"hash": "eKldOLq51V3", "uri": "/contracts/eKldOLq51V3#temporary-structures", "label": "Rental Agreement", "score": 24.5482540131, "published": true}, {"hash": "apPXb3xUP54", "uri": "/contracts/apPXb3xUP54#temporary-structures", "label": "Rental Agreement", "score": 24.4496917725, "published": true}], "hash": "1ccf0eec7d4946183e2d51971a8e9ea9", "id": 5}, {"snippet_links": [{"key": "installation-of", "type": "clause", "offset": [0, 15]}, {"key": "temporary-construction", "type": "clause", "offset": [16, 38]}], "snippet": "Installation of temporary construction-related structures including scaffolding, barriers, screening, fences, protective walkways, signage, office trailers or restrooms.", "size": 24, "samples": [{"hash": "2OIYehe9lm4", "uri": "/contracts/2OIYehe9lm4#temporary-structures", "label": "Programmatic Agreement", "score": 34.5390205383, "published": true}, {"hash": "1FMsMfqLNZn", "uri": "/contracts/1FMsMfqLNZn#temporary-structures", "label": "Programmatic Agreement", "score": 31.8390388489, "published": true}, {"hash": "ap3uvkJIUAQ", "uri": "/contracts/ap3uvkJIUAQ#temporary-structures", "label": "Programmatic Agreement", "score": 31.8327789307, "published": true}], "hash": "619bb41bd9f77eec757440aafdf8fbf0", "id": 1}, {"snippet_links": [{"key": "to-the-extent", "type": "clause", "offset": [0, 13]}, {"key": "cost-component", "type": "definition", "offset": [36, 50]}, {"key": "change-order-sum", "type": "clause", "offset": [58, 74]}, {"key": "estimated-actual-costs", "type": "definition", "offset": [84, 106]}, {"key": "structures-and-equipment", "type": "clause", "offset": [158, 182]}, {"key": "incident-to", "type": "definition", "offset": [183, 194]}, {"key": "own-forces", "type": "definition", "offset": [215, 225]}, {"key": "the-proposed", "type": "clause", "offset": [241, 253]}, {"key": "component-change-order", "type": "clause", "offset": [254, 276]}, {"key": "proposed-budget", "type": "definition", "offset": [346, 361]}, {"key": "proposed-plan", "type": "definition", "offset": [383, 396]}, {"key": "the-owner", "type": "clause", "offset": [431, 440]}, {"key": "office-facilities", "type": "definition", "offset": [484, 501]}, {"key": "by-owner", "type": "definition", "offset": [612, 620]}, {"key": "sales-price", "type": "clause", "offset": [712, 723]}, {"key": "rental-rate", "type": "definition", "offset": [727, 738]}, {"key": "proportionately-reduced", "type": "definition", "offset": [769, 792]}], "snippet": "To the extent the CM/GC's Estimated Cost Component of the Change Order Sum includes estimated Actual Costs for CM/GC's on-site offices or for other temporary structures and equipment incident to mobilization of its own forces for Work under the proposed Component Change Order, CM/GC shall submit as part of its proposed Component Change Order a proposed budget for such costs and a proposed plan for acquisition of such items. If the Owner approves the provision by CM/GC of on-site office facilities and other temporary structures and equipment from CM/GC's own inventory, then no CM/GC's Fee shall be payable by Owner on account of such self-provided facilities (in excess of any fee included in the approved sales price or rental rate) and the CM/GC's Fee shall be proportionately reduced.", "size": 15, "samples": [{"hash": "WwViTmUYKE", "uri": "/contracts/WwViTmUYKE#temporary-structures", "label": "Construction Management Agreement", "score": 32.8100204468, "published": true}, {"hash": "f0dkjM8y12w", "uri": "/contracts/f0dkjM8y12w#temporary-structures", "label": "Construction Management Agreement", "score": 32.3980331421, "published": true}, {"hash": "5QHW3pm6j55", "uri": "/contracts/5QHW3pm6j55#temporary-structures", "label": "Construction Management Agreement", "score": 31.5207195282, "published": true}], "hash": "762673f18d35f4cbc48cb9d46ddb6d9b", "id": 3}, {"snippet_links": [{"key": "motor-home", "type": "definition", "offset": [39, 49]}, {"key": "other-building", "type": "definition", "offset": [99, 113]}, {"key": "at-any-time", "type": "clause", "offset": [137, 148]}], "snippet": "No structure of a temporary character, motor home, trailer, basement, tent, shack, garage, barn or other building may be used on any lot at any time as a residence either temporarily or permanently.", "size": 6, "samples": [{"hash": "1HkZLCdpjmI", "uri": "/contracts/1HkZLCdpjmI#temporary-structures", "label": "Declaration of Restrictions", "score": 31.8611755371, "published": true}, {"hash": "9oLdoeT5kR", "uri": "/contracts/9oLdoeT5kR#temporary-structures", "label": "Declaration of Restrictions", "score": 21.2956886292, "published": true}], "hash": "f06844164ac03b81dc2c2013ea9660cf", "id": 7}, {"snippet_links": [{"key": "to-the-extent", "type": "clause", "offset": [0, 13]}, {"key": "the-design", "type": "clause", "offset": [14, 24]}, {"key": "cost-component", "type": "definition", "offset": [45, 59]}, {"key": "change-order-sum", "type": "clause", "offset": [67, 83]}, {"key": "estimated-actual-costs", "type": "definition", "offset": [93, 115]}, {"key": "structures-and-equipment", "type": "clause", "offset": [176, 200]}, {"key": "incident-to", "type": "definition", "offset": [201, 212]}, {"key": "own-forces", "type": "definition", "offset": [233, 243]}, {"key": "the-proposed", "type": "clause", "offset": [259, 271]}, {"key": "component-change-order", "type": "clause", "offset": [272, 294]}, {"key": "proposed-budget", "type": "definition", "offset": [373, 388]}, {"key": "proposed-plan", "type": "definition", "offset": [410, 423]}, {"key": "the-owner", "type": "clause", "offset": [458, 467]}, {"key": "office-facilities", "type": "definition", "offset": [520, 537]}, {"key": "by-owner", "type": "definition", "offset": [666, 674]}, {"key": "sales-price", "type": "clause", "offset": [766, 777]}, {"key": "rental-rate", "type": "definition", "offset": [781, 792]}, {"key": "proportionately-reduced", "type": "definition", "offset": [832, 855]}], "snippet": "To the extent the Design-Builder's Estimated Cost Component of the Change Order Sum includes estimated Actual Costs for Design-Builder's on-site offices or for other temporary structures and equipment incident to mobilization of its own forces for Work under the proposed Component Change Order, Design-Builder shall submit as part of its proposed Component Change Order a proposed budget for such costs and a proposed plan for acquisition of such items. If the Owner approves the provision by Design-Builder of on-site office facilities and other temporary structures and equipment from Design-Builder's own inventory, then no Design-Builder's Fee shall be payable by Owner on account of such self-provided facilities (in excess of any fee included in the approved sales price or rental rate) and the Design-Builder's Fee shall be proportionately reduced.", "size": 17, "samples": [{"hash": "iRw5lY7fyjK", "uri": "/contracts/iRw5lY7fyjK#temporary-structures", "label": "Design Build Contract", "score": 34.5430831909, "published": true}, {"hash": "2IvsvLuWUB", "uri": "/contracts/2IvsvLuWUB#temporary-structures", "label": "Design Build Contract", "score": 34.5223617554, "published": true}, {"hash": "c53NTyeRv2A", "uri": "/contracts/c53NTyeRv2A#temporary-structures", "label": "Design Build Contract", "score": 33.5207176208, "published": true}], "hash": "67085ec756ebe6ac705332100a4a7bbe", "id": 2}, {"snippet_links": [{"key": "plan-submittals", "type": "clause", "offset": [69, 84]}, {"key": "not-limited", "type": "clause", "offset": [124, 135]}, {"key": "prepared-by", "type": "definition", "offset": [230, 241]}, {"key": "professional-engineer", "type": "clause", "offset": [244, 265]}, {"key": "qualified-firm", "type": "definition", "offset": [285, 299]}, {"key": "in-addition-to-the-above", "type": "clause", "offset": [301, 325]}, {"key": "conform-with", "type": "definition", "offset": [344, 356]}, {"key": "work-includes", "type": "clause", "offset": [396, 409]}, {"key": "the-contractor-shall", "type": "clause", "offset": [466, 486]}, {"key": "the-district", "type": "clause", "offset": [508, 520]}, {"key": "authorities-having-jurisdiction", "type": "definition", "offset": [522, 553]}, {"key": "protection-of-work-in-progress", "type": "clause", "offset": [602, 632]}, {"key": "adjacent-to", "type": "definition", "offset": [633, 644]}, {"key": "load-requirements", "type": "clause", "offset": [675, 692]}, {"key": "minimum-requirements", "type": "clause", "offset": [703, 723]}, {"key": "based-on", "type": "definition", "offset": [724, 732]}, {"key": "project-location", "type": "definition", "offset": [733, 749]}], "snippet": "Contractor shall be required, at the Contractor\u2019s expense, to create plan submittals for temporary structures including but not limited to: scaffolding, work platforms, structurally supporting temporary walls, etc. Plans shall be prepared by a professional engineer and installed by a qualified firm. In addition to the above, structures shall conform with current OSHA-OR requirements. When the work includes scaffolding or supporting temporary structures/shoring, the Contractor shall obtain approval from the District, Authorities Having Jurisdiction (as necessary), and Architect/Engineer. Weather protection of work in progress adjacent to temporary structures and wind load requirements will meet minimum requirements based on project location.", "size": 10, "samples": [{"hash": "lvOq9yXfiEC", "uri": "/contracts/lvOq9yXfiEC#temporary-structures", "label": "Flexible Services Contract", "score": 35.3413467407, "published": true}, {"hash": "5qlCeGbHBK6", "uri": "/contracts/5qlCeGbHBK6#temporary-structures", "label": "Flexible Services Contract", "score": 35.0711135864, "published": true}, {"hash": "49ar8jiravZ", "uri": "/contracts/49ar8jiravZ#temporary-structures", "label": "Flexible Services Contract", "score": 34.1804237366, "published": true}], "hash": "0e7f25d79ce2ccc3bc21d51c37c00e24", "id": 4}, {"snippet_links": [{"key": "the-design", "type": "clause", "offset": [0, 10]}, {"key": "necessary-for", "type": "definition", "offset": [93, 106]}, {"key": "the-materials", "type": "clause", "offset": [227, 240]}, {"key": "the-property", "type": "clause", "offset": [272, 284]}, {"key": "proposed-design", "type": "clause", "offset": [312, 327]}, {"key": "the-department", "type": "clause", "offset": [374, 388]}, {"key": "prior-to-the", "type": "clause", "offset": [389, 401]}, {"key": "beginning-of-construction", "type": "definition", "offset": [402, 427]}, {"key": "in-accordance-with", "type": "clause", "offset": [428, 446]}], "snippet": "The Design-Builder shall construct, maintain, and remove temporary structures and approaches necessary for use by traffic. After new structures have been opened to traffic, temporary structures and approaches shall be removed. The materials contained therein shall remain the property of the Design-Builder. The proposed design of temporary structures shall be submitted to the Department prior to the beginning of construction in accordance with Section 105.10.", "size": 5, "samples": [{"hash": "awIQ26zfNs6", "uri": "/contracts/awIQ26zfNs6#temporary-structures", "label": "Lump Sum Design Build Agreement", "score": 24.4455852509, "published": true}, {"hash": "3YSfKUzwePg", "uri": "/contracts/3YSfKUzwePg#temporary-structures", "label": "Lump Sum Design Build Agreement", "score": 24.4442157745, "published": true}], "hash": "6ddafa7fe64a30011df0455735954f15", "id": 10}, {"snippet_links": [{"key": "not-limited", "type": "clause", "offset": [53, 64]}, {"key": "at-any-time", "type": "clause", "offset": [123, 134]}, {"key": "prefabricated-building", "type": "definition", "offset": [215, 237]}, {"key": "written-permission", "type": "clause", "offset": [298, 316]}], "snippet": "No structure of a temporary character (including but not limited to trailers, tents, shacks, garages or barns) may be used at any time as a residence, either temporarily or permanently. Additionally, no portable or prefabricated building or dog pen shall be located upon any lot without the prior, written permission of the TDHE.", "size": 5, "samples": [{"hash": "gGVYFKNXeCE", "uri": "/contracts/gGVYFKNXeCE#temporary-structures", "label": "Low Rent Eligibility Admissions, Occupancy, and Payment Policy", "score": 32.7891540527, "published": true}, {"hash": "hr1dEzmiNP3", "uri": "/contracts/hr1dEzmiNP3#temporary-structures", "label": "Low Rent Eligibility Admissions, Occupancy, and Payment Policy", "score": 30.7241458893, "published": true}, {"hash": "ds4WOkEucTs", "uri": "/contracts/ds4WOkEucTs#temporary-structures", "label": "Rental Eligibility Admissions, Occupancy, and Payment Policy", "score": 22.3730316162, "published": true}], "hash": "8476cdd3f9a16ff40473ed22bf296007", "id": 9}, {"snippet_links": [{"key": "the-contractor-shall", "type": "clause", "offset": [0, 20]}, {"key": "own-cost", "type": "clause", "offset": [47, 55]}, {"key": "approved-by", "type": "clause", "offset": [115, 126]}, {"key": "the-superintending-engineer", "type": "definition", "offset": [127, 154]}, {"key": "own-expenses", "type": "clause", "offset": [239, 251]}, {"key": "temporary-fences", "type": "clause", "offset": [257, 273]}, {"key": "necessary-for", "type": "definition", "offset": [298, 311]}, {"key": "the-execution", "type": "clause", "offset": [312, 325]}, {"key": "contract-work", "type": "definition", "offset": [333, 346]}, {"key": "the-public", "type": "clause", "offset": [385, 395]}, {"key": "by-the-contractor", "type": "clause", "offset": [481, 498]}, {"key": "comply-with", "type": "clause", "offset": [520, 531]}, {"key": "issue-to", "type": "definition", "offset": [579, 587]}], "snippet": "The contractor shall erect and maintain at his own cost temporary weather-proof sheds at such places and in manner approved by the Superintending Engineer for keeping materials under cover. The contract shall also provide and maintain his own expenses such temporary fences, guards, etc., as ay be necessary for the execution of his contract work or for safe guarding or accommodating the public. If the Superintending Engineer shall order any departure from any arrangements made by the contractor the contractor shall comply with such orders as the Superintending Engineer may issue to safeguard or accommodate the public.", "size": 6, "samples": [{"hash": "4QPlbgWh3Qj", "uri": "/contracts/4QPlbgWh3Qj#temporary-structures", "label": "Contract", "score": 21.3722820282, "published": true}, {"hash": "3XKo9GGvJwR", "uri": "/contracts/3XKo9GGvJwR#temporary-structures", "label": "Contract", "score": 21.3722820282, "published": true}, {"hash": "o0QH4uApN5", "uri": "/contracts/o0QH4uApN5#temporary-structures", "label": "Construction Contract", "score": 21.1765918732, "published": true}], "hash": "86244972b39618d2ad9dc8af8af91ac7", "id": 6}, {"snippet_links": [{"key": "the-hirer-shall", "type": "clause", "offset": [0, 15]}, {"key": "temporary-structure", "type": "definition", "offset": [73, 92]}, {"key": "the-venue", "type": "definition", "offset": [144, 153]}, {"key": "approval-of", "type": "definition", "offset": [190, 201]}, {"key": "operations-manager", "type": "definition", "offset": [206, 224]}], "snippet": "The Hirer shall not construct or erect any rigging, scaffolding or other temporary structure or suspend any object or thing from the ceiling of The Venue without obtaining the prior written approval of the Operations Manager.", "size": 6, "samples": [{"hash": "dTcT7lSk9zP", "uri": "/contracts/dTcT7lSk9zP#temporary-structures", "label": "Venue Hire Agreement", "score": 33.4196777344, "published": true}], "hash": "156169cc4815f8d9cd15d0d24d5e3955", "id": 8}], "next_curs": "Cl0SV2oVc35sYXdpbnNpZGVyY29udHJhY3RzcjkLEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2Ih10ZW1wb3Jhcnktc3RydWN0dXJlcyMwMDAwMDAwYQyiAQJlbhgAIAA=", "clause": {"parents": [["mobilization-costs", "Mobilization Costs"], ["execution-and-implementation", "EXECUTION AND IMPLEMENTATION"], ["full-agreement", "Full Agreement"], ["responsibility-for-completion", "Responsibility for Completion"], ["procedures-for-approval-of-materials", "Procedures for Approval of Materials"]], "title": "Temporary Structures", "size": 227, "children": [["maximum-liability", "Maximum Liability"], ["construction-progress-schedule", "Construction Progress Schedule"], ["maximum-sum-calculated", "Maximum Sum Calculated"], ["", ""], ["grade-separated-crossing", "Grade Separated Crossing"]], "id": "temporary-structures", "related": [["temporary-schedule-changes", "Temporary Schedule Changes", "Temporary Schedule Changes"], ["temporary-roads", "Temporary Roads", "Temporary Roads"], ["temporary-suspension", "Temporary Suspension", "Temporary Suspension"], ["temporary-upgrade", "Temporary Upgrade", "Temporary Upgrade"], ["temporary-layoffs", "Temporary Layoffs", "Temporary Layoffs"]], "related_snippets": [], "updated": "2025-07-24T04:27:51+00:00"}, "json": true, "cursor": ""}}