SYSTEM INSTRUCTION/DIAGRAM PLATES Sample Clauses

SYSTEM INSTRUCTION/DIAGRAM PLATES. The Contractor shall provide and install a set of engraved phenolic instruction plates for the fuel oil system located near each of the fuel oil pumps. Each set shall consist of a plate with the system schematic, and a second plate with instructions on operation, valve alignment, cross-over, etc. to include valve labels that correspond to the schematic. The Contractor shall submit the plate designs and final locations to the COR for review and approval. The reference document titled “793 - SAMPLE PLACARD” is included to provide an example of the instruction plates from a previous Marine Design Center project. C637 WASTE OIL SYSTEM
AutoNDA by SimpleDocs
SYSTEM INSTRUCTION/DIAGRAM PLATES. The Contractor shall provide and install a set of engraved phenolic instruction plates for the ballast system located near the pump. System Instruction/Diagram Plates are not required for the Bilge System. Each set shall consist of a plate with the system schematic, and a second plate with instructions on operation, valve alignment, cross-over, etc. to include valve labels that correspond to the schematic. The Contractor shall submit the plate designs and final locations to the COR for review and approval. The reference document named “793 - SAMPLE PLACARD” is included to provide an example of the instruction plates from a previous Marine Design Center project. C665 POTABLE WATER SYSTEM
SYSTEM INSTRUCTION/DIAGRAM PLATES. The Contractor shall provide and install a set of engraved phenolic instruction plates for the deck washdown system located near the pump. The set shall consist of a plate with the system schematic, and a second plate with instructions on operation, valve alignment, cross-over, etc. to include valve labels that correspond to the schematic. The Contractor shall submit the plate designs and final locations to the COR for review and approval. The reference drawing named “793 - SAMPLE PLACARD” is included to provide an example of the instruction plates from a previous Marine Design Center project. C678 FIRE DETECTION & ALARM SYSTEM

Related to SYSTEM INSTRUCTION/DIAGRAM PLATES

  • Escrow Format Specification 3.1. Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Technical Specifications 1. A procuring entity shall not prepare, adopt or apply any technical specification or prescribe any conformity assessment procedure with the purpose or effect of creating an unnecessary obstacle to trade between the Parties.

  • ODUF Packing Specifications 6.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • Purchase Order Flip via Ariba Network (AN) The online process allows suppliers to submit invoices via the AN for catalog and non- catalog goods and services. Contractors have the ability to create an invoice directly from their Inbox in their AN account by simply “flipping” the purchase order into an invoice. This option does not require any special software or technical capabilities. For the purposes of this section, the Contractor warrants and represents that it is authorized and empowered to and hereby grants the State and the third-party provider of MFMP the right and license to use, reproduce, transmit, distribute, and publicly display within the system the information outlined above. In addition, the Contractor warrants and represents that it is authorized and empowered to and hereby grants the State and the third-party provider the right and license to reproduce and display within the system the Contractor’s trademarks, system marks, logos, trade dress, or other branding designation that identifies the products made available by the Contractor under the Contract.

  • Instructional Materials A. The Board recognizes that appropriate texts, library reference facilities, maps and globes, laboratory equipment, audio-visual equipment, art supplies, athletic equipment, current periodicals, standard tests and questionnaires, computers, and similar materials are the tools of the teaching profession.

  • General specifications 6.1.1. A vehicle and its electrical/electronic system(s) or ESA(s) shall be so designed, constructed and fitted as to enable the vehicle, in normal conditions of use, to comply with the requirements of this Regulation.

  • Construction materials (1) The restrictions of section 1605 of the American Recovery and Reinvestment Act of 2009 (Pub. L. 111-5) (Recovery Act) do not apply to Recovery Act designated country manufactured construction material. The restrictions of the Buy American statute do not apply to designated country unmanufactured construction material. Consistent with U.S. obligations under international agreements, this clause implements--

  • Project Implementation Manual The Recipient, through the PCU, shall: (i) take all action required to carry out Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4 (ii) of the Project in accordance with the provisions and requirements set forth or referred to in the Project Implementation Manual; (ii) submit recommendations to the Association for its consideration for changes and updates of the Project Implementation Manual as they may become necessary or advisable during Project implementation in order to achieve the objective of Parts 1.1, 1.3, 1.4, 2, 3.1(b), 3.2, 3.3 and 4(ii) of the Project; and (iii) not assign, amend, abrogate or waive the Project Implementation Manual or any of its provisions without the Association’s prior agreement. Notwithstanding the foregoing, if any of the provisions of the Project Implementation Manual is inconsistent with the provisions of this Agreement, the provisions of this Agreement shall prevail and govern.

  • MSAA Indicator Technical Specification Document This Agreement shall be interpreted with reference to the MSAA Indicator Technical Specifications document.

  • Project Manual A bound manual prepared by the Design Professional. It includes the Invitation to Bid, Instructions to Bidders, the Bid Form, the Specifications, the General Conditions and Supplementary General Conditions.