Scope of Specification Sample Clauses

Scope of Specification. The following criteria cover the general requirements for the installation of instrumentation and control systems. The scope of work covered by this specification includes, but is not limited to, installation and support of field instruments, instrument impulse lines, pneumatic signal lines, sample lines, and local instrument cabinets. The use of eyewash stations and showers shall be alarmed in the DCS. No primary sensor full-scale signal level, other than thermocouples, will be less than 10 mV or greater than 125 V. To the extent practical, instrumentation will be standardized. Instrument analog signals for electronic instrument systems shall be 4 to 20 ma dc. Instrument analog signals for pneumatic instrument systems shall be 3 to 15 psig. Use of pneumatic controls shall be limited to applications where sub-supplier standard designs cannot be provided without them. Local indicating controllers (if required) shall be furnished with an auto-manual function switch. The following units of measurement shall be used in process measurement and control. English units are preferred, but metric units may be used when in common practice: Parameter Units of Measurement Temperature degrees Fahrenheit (o F) Pressure pounds per square inch gauge (psig) inches of water column (in wc) or (inH2O) pounds per square inch absolute (psia) inches of mercury absolute (HgA) Level General percent Tank Gauge linear feet, inches, and tenths of inches Deviation from normal level Flow Liquids gallons per minute (gpm) pounds per hour (pph or #/hr) Gases and Vapors standard cubic feet per minute at 60 OF (SCFM) standard cubic feet per hour at 60 OF (SCFH) Steam and Boiler Feedwater pounds per hour (pph or #/hr) Solids pounds per hour (pph or #/hr) tons per day (tpd) Steam & Water Sampling pH pH (pH Units) Specific conductivity S/cm Cation conductivity S/cm Degassed cation conductivity S/cm Dissolved oxygen parts per billion (ppb) Silica or sodium parts per billion (ppb) Oxygen scavenger parts per billion (ppb) Sulfate, phosphate, chloride parts per billion (ppb) Permanently attached stainless steel tags shall be purchased with all major instrument equipment. Each tag shall carry the item tag number. This tag is in addition to the nameplate, which provides the manufacturer's model number and other data. Thermocouple and test xxxxx shall have the material of construction stamped on the well. If tag numbers are assigned to these xxxxx, the number shall also be stamped on the well. Inst...
AutoNDA by SimpleDocs
Scope of Specification. By implementing the solution, EuroTel Bratislava intends to simplify the processes and interfaces to be able to minimize or replace many of today's components. [LOGO OF CAP GEMINI ERNST & YOUNG] [LOGO OF EUROTEL] -------------------------------------------------------------------------------- Appendix I Scope of Delivery The main interfaces for the BMD shall be: Input o Ericsson AXE MSC's (GSM1,2&3) o Nokia Switches (NMT1&2) o SMS centres (SMSC) o Roaming (TAP3 from MACH & TAP2+ from EuroTel Prague) Data from Network Elements is requested by polling and two types of polling are included. One is set by the clock and the frequency can be from one minute up to 24 hours. The other is event driven whereby the BMD will fetch the CDR file right after it has been created in a directory. o SICAP replacement of CDR handler and DB loader. BMD will mediate ASN.1 data to SICAP system. o CDR Loader replacement- BMD will mediate data as input to Interconnect, VOIP, Security and FDS system.. o BSCS interfacing RIH modul The aim is also for the BMD to reduce the number of standard modules used in the existing systems hence improving performance. The following BSCS processes will be replaced: - File Input Handler (FIH) - Duplicate Record Handler (DRH) - Assembled Input Handler (AIH) By using a new BMD based on standard BMP mediation functionality, the following utilities and programs will be realized within the solution: o In-house developed CDR Collector The present CDR Collector used by EuroTel will be replaced by the standard BMP Collection functionality as defined in section 2.4.3.(WP3 Collector Set-up) and subsection Formatting in section 2.4.5. (WP5 Processing). o Splitter Filtering of post-paid and pre-paid CDRs will be handled using the standard BMP processing nodes described in section 2.4.5. (WP5 Processing). Pre Paid Number Duplicity is not allowed: This is supported by the Duplicate CDR Detection functionality which is a standard processing node in BMP [LOGO OF CAP GEMINI ERNST & YOUNG] [LOGO OF EUROTEL] -------------------------------------------------------------------------------- Appendix I Scope of Delivery o SMS converter CDR based on SMS activity will be processed and converted to the required output format using standard BMP processing nodes described in section 2.4.5 (WP5 Processing) o TAP conversions BMP can handle the TAP2+ and TAP3 formats and process such CDRs using standard BMP processing nodes described in section (WP5 Processing). o Star numbers ...
Scope of Specification. Your proposal should demonstrate a full understanding of all aspects of the specification to enable reliable delivery of the required services. Concateno UK Concateno are the incumbent supplier to the HMPS CBDT programme and propose to continue to supply the Authority with the same high quality of product and support service to the same standard as they have been receiving. We are well placed through our extensive knowledge of drug testing to fully understand and continue to deliver all aspects of the specification of this contract to enable reliable delivery of the required services. Concateno already has in place a successful stock management system based on patterns of kit usage by the establishments xxxx redacted text xxxx. Therefore Concateno are ready to supply the product offerings from day one of contract implementation. By assessing the monthly order patters from establishments, we are able to meet fluctuating demands in kit orders and use. Concateno continue to offer a full customer support package and will provide as much information as possible in a simple and easy to digest format during training sessions We also offer a comprehensive technical support service to address issues associated with kit operation, specificity/interference issues and the interpretation of results. The following facilities are available: • Telephone support on general drug issues, product specific issues and service provisions issues. • Online technical information on all productsAccess to local account managers for general issues Concateno operates a HELPLINE (0800 169 5167) which can be accessed from 8.00 a.m. until 8.00 p.m., 7 days a week, 365 days a year. Product information is presented on our website. The cross-reactivity data we supply is also be made available to the HMP intranet site. All technical queries are periodically reviewed and collated into a frequently asked questions (FAQ) document for distributions. General Queries Concateno has a customer support and order processing team, plus an accounts department available during normal working hours to answer any queries that may be raised. In addition we operate a HELPLINE (0800 169 5167) which can be accessed from 8.00 a.m. until 8.00 p.m., 7 days a week, 365 days a year. Product information is presented on our website, plus enquiries and orders can be received electronically. Attached are the last 12 months quality assurance certificates relating to the Concateno product offering (as per the products ...

Related to Scope of Specification

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Escrow Format Specification 3.1. Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.

  • Technical Specifications 1. A procuring entity shall not prepare, adopt or apply any technical specification or prescribe any conformity assessment procedure with the purpose or effect of creating an unnecessary obstacle to trade between the Parties.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • General specifications 6.1.1. A vehicle and its electrical/electronic system(s) or ESA(s) shall be so designed, constructed and fitted as to enable the vehicle, in normal conditions of use, to comply with the requirements of this Regulation.

  • Health plan specification The Employer will require health plans participating in the Group Insurance Program to develop and implement health promotion and health education programs for State employees and their dependents.

  • Changes to Specifications All Specifications and any changes thereto agreed to by the Parties from time to time shall be in writing, dated and signed by the Parties. No change in the Specifications shall be implemented by Cardinal Health, whether requested by Reliant or requested or required by any Regulatory Authority, until the Parties have agreed in writing to such change, the implementation date of such change, and any increase or decrease in costs, expenses or fees associated with such change. Cardinal Health shall respond promptly to any request made by Reliant for a change in the Specifications, and both Parties shall use commercially reasonable, good faith efforts to agree to the terms of such change in a timely manner. If after initial Product qualification, Reliant requests a change in the Specifications for its own benefit or to comply with the requirements of a Regulatory Authority, the Specifications shall be amended as soon as [***]: Certain information on this page has been omitted and filed separately with the Commission. Confidential treatment has been requested with respect to the omitted portions. possible after a request is made for any change in Specifications, and Cardinal Health shall notify Reliant of the costs associated with such change and shall provide such supporting documentation as Reliant may reasonably require. Reliant shall pay all costs associated with such Reliant-requested changes or changes required by a Regulatory Authority as may be agreed upon by the Parties. Changes, agreed to between the Parties, for the benefit of Cardinal Health, shall be at the expense of Cardinal Health. If there is a conflict between the terms of this Agreement and the terms of the Specifications, this Agreement shall control.

  • Packing Specifications 7.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

  • ODUF Packing Specifications 6.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

Time is Money Join Law Insider Premium to draft better contracts faster.