Power Supply System Sample Clauses

Power Supply System. (a) Estimation of additional power supply requirement.
AutoNDA by SimpleDocs
Power Supply System. Power supply to fire0fighting systems, security systems and elevators is provided in category I. The Building maintenance systems belong to a special electroreceiver group of category I. The system of steady power supply (3rd independent power supply source) on the basis of 2 diesel generators is anticipated in the Building. The load of the first category consumers is 799kWA. To the Building maintenance systems belong: Electrical motors of the pumps for fire fighting; Water pipelines in the Building; Equipment for the systems of automatic fire extinguishing in the Building; Elevators equipment; Electro-equipment for smoke ventilation; Equipment for fire alarm warning; 85 Equipment for the Building safety systems; Equipment for dispatching systems; Emergency lighting of the Building; Fire setback valves; Bank equipment; Smoke removal valves. Video access control sources of continuous feeding are installed for steady reliable power supply to such equipment as automatic fire alarm warning and signaling. Power supply to the complex of other electro-receivers in the Building will be provided on category II.
Power Supply System. Power Conditioner • 5 KVA 1 hour backup main UPS with one set (15 nos. each) of 12 volt battery. • 1 KVA UPS in the equipment cabinet. South Eastern Railway TENDER NO. TDS/AMC.07 Annexure- B PREVENTIVE MAINTENANCE SCHEDULE OF SIMULATOR
Power Supply System. Scope of Power supply System comprises detailed design, construction, testing and commissioning of the Power Supply System for the two Corridors and a Depot. The Power Supply System shall consist of:  erection and commissioning of three 110 kV AC Receiving Substations, related Auxiliary Main Substations (3) and Traction Main Substations (3), including all civil works  all civil works and equipment for the 25 kV AC power supply,  33 KV cable rings and the equipment of all the stations (13 Elevated & 19 Underground) and a Depot, including 33kV/415V transformers, DG sets,  SCADA. The scope of works includes but not limited to:  Provision of GIS/AIS Receiving substation and related Auxiliary Main Substation, Traction Main Substation, including all civil works, associated cabling and earth provision  33 KV Cable Ring Main Network along Two corridors of Phase-1 for Station Auxiliaries.  33 KV/ 415 V, metro rail type, with indoor Type Air Insulated/ Gas Insulated Sub-stations with all Switchgear and Dry Type Transformers at all the stations (13 Elevated & 19 Underground) and a Depot. All these Sub-stations shall have provision for remote monitoring and control to enable through SCADA. Local monitoring and control shall be made with screen control panel with ergonomic and easy operating screen views.  Digital Protection Control System (using fast acting relays and PLCs) providing all the data acquisition, data processing, overall protection control, interlocking, inter-tripping and monitoring of the entire power supply system SCADA system.  SCADA system for auxiliary supply (33 KV and below) and 25 KV supply for traction.  Interface between Power Supply System SCADA and Receiving Sub Station (RSS) equipments  Standby Power supply ie, Diesel Generators of suitable rating with AMF panel required to meet the station Auxiliary loads in case of Main supply failure. Overhead Equipment (OHE) Scope of Overhead Equipment comprises detailed design, construction, testing and commissioning of the 25 kV AC Overhead Equipment for the two Corridors and a Depot. The OHE shall consist of simple catenaries system for 40 Km (approximate) Track length (measured as single track) in the main lines on elevated sections and at grade sections and rigid conductors for underground section (approximately 50 Km). In the Depot (Koyambedu Depot), the OHE shall be single contact wire for stabling, workshops, Washing/Pit Lines etc (approximately 20 Km measured as single track). The sco...

Related to Power Supply System

  • Power Supply Electric Power supply for carrying out his work shall be arranged by contractor on his own cost at the site and energy charges shall be borne by the contractor.

  • Water Supply The system may or may not meet state and local requirements. It is the right and responsibility of Buyer to determine the compliance of the system with state and local requirements. [For additional information on this subject, request the “Water Supply and Waste Disposal Notification” form.]

  • Direct Contracting Goods and works which the Association agrees meet the requirements for Direct Contracting may be procured in accordance with the provisions of said procurement method.

  • Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5.1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Interconnection Customer Authority Consistent with Good Utility Practice, this LGIA, and the CAISO Tariff, the Interconnection Customer may take actions or inactions with regard to the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities during an Emergency Condition in order to (i) preserve public health and safety, (ii) preserve the reliability of the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities,

  • Interconnection Customer (1) Interconnection Customer shall construct and, unless otherwise indicated, shall own, the following Interconnection Facilities: None

  • Telemedicine Services This plan covers clinically appropriate telemedicine services when the service is provided via remote access through an on-line service or other interactive audio and video telecommunications system in accordance with R.I. General Law § 27-81-1. Clinically appropriate telemedicine services may be obtained from a network provider, and from our designated telemedicine service provider. When you seek telemedicine services from our designated telemedicine service provider, the amount you pay is listed in the Summary of Medical Benefits. When you receive a covered healthcare service from a network provider via remote access, the amount you pay depends on the covered healthcare service you receive, as indicated in the Summary of Medical Benefits. For information about telemedicine services, our designated telemedicine service provider, and how to access telemedicine services, please visit our website or contact our Customer Service Department.

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • One-Way Interconnection Trunks 2.3.1 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from CBB to Verizon, CBB, at CBB’s own expense, shall:

Time is Money Join Law Insider Premium to draft better contracts faster.