Points of Delivery Sample Clauses

Points of Delivery. The "Point(s) of Delivery" shall be the point(s) on Transporter(s)' pipeline system(s) where gas is delivered by Seller to Transporter(s) for Buyer's account, as specified in Exhibit C attached hereto and made a part hereof. As between the parties hereto, title, risk of loss, and liabilities associated with delivered gas shall pass to and vest in Buyer at the Point(s) of Delivery. Changes in the Point(s) of Delivery shall require the mutual consent of the parties.
AutoNDA by SimpleDocs
Points of Delivery. TRANSMISSION Output power supplied hereunder shall be approximately 230 kV or 115 kV, three-phase, alternating current, at approximately 60 hertz. The Energy to be delivered hereunder shall be made available to the Purchaser, at its option subject to transmission limitations as determined by the District, exercisable from time to time, at any one or more of the following Points of Delivery: Cascade (formerly White River) – Rocky Reach 230 kV Transmission Line (Puget Sound Energy interconnection) Location: The point(s) where the Chelan Transmission System interconnects with Puget’s Cascade – Rocky Reach 230 kV transmission line in the vicinity of the Rocky Reach Switchyard Voltage: 230 kV Maple Valley – Rocky Reach 230/345 kV Transmission Line (BPA interconnection) Location: The point(s) where the Chelan Transmission System interconnects with BPA’s 230/345 kV step-up transformer facilities that in turn feed BPA’s Maple Valley – Rocky Reach 230/345 kV transmission line in the vicinity of the Rocky Reach Switchyard Voltage: 230 kV Rocky Reach – Columbia #2 230 kV Transmission Line (BPA interconnection) Location: The point(s) where the Chelan Transmission System interconnects with BPA’s 230 kV bus in the vicinity of BPA’s Columbia Substation Voltage: 230 kV Chelan Rocky Reach – Columbia #2 230 kV Transmission Line (Grant contractual interconnection) Location: The point(s) where the Chelan Transmission System interconnects with Grant County PUD’s Columbia – Wanapum 230 kV line in the vicinity of BPA’s Columbia Substation Voltage: 230 kV Rocky Reach – Columbia #1 230 kV Transmission Line (BPA interconnection) Location: The point(s) where the Chelan Transmission System interconnects with BPA’s Rocky Reach – Columbia 230 kV line in the vicinity of the Rocky Reach Switchyard Voltage: 230 kV Rocky Reach – Xxxxxxx 230 kV Tie Line (Xxxxxxx PUD interconnection) Location: The point(s) where the Chelan Transmission System interconnects with Xxxxxxx County PUD’s 230 kV system in the vicinity of the Rocky Reach Switchyard Voltage: 230 kV Valhalla Substation (Rock Island) (BPA interconnection) Location: The point(s) where the Chelan Transmission System interconnects with BPA at 115kV in the vicinity of the BPA 115kV Switchyard and XxXxxxxx 115kV Switchyard. Voltage: 115 kV At any other location mutually agreed to by the District and Purchaser. Purchaser is responsible for obtaining all necessary transmission capacity and for arranging, scheduling, and paying associated cost...
Points of Delivery. Supplier shall deliver, and -------------------- Buyer shall take delivery of, the Supply Amount of Energy at the Point(s)
Points of Delivery. The Point(s) of Delivery for all gas to be tendered by Bay Gas to Shipper for delivery pursuant to the terms hereof shall be as specified on Exhibit “A”, and the maximum daily quantities of gas which Bay Gas is obligated to deliver to Shipper at each such individual Point of Delivery shall not exceed the maximum stated thereon.
Points of Delivery. Seller shall redeliver to Buyer or for the account of Buyer the gas transported hereunder at the following point(s) of delivery and at a pressure(s) of: See Exhibit B, attached hereto, for points of delivery and pressures.
Points of Delivery. The Point of Points of Delivery for all natural gas delivered by Seller to Buyer under this agreement shall be at or near:
Points of Delivery. The 23D-kV switchrack at the Mirage Substation site where Edison's 23O-kV facilities are attached to IID's 230-kV Coachella-Mirage Line or other points as may be mutually agreed upon by the Authorized Representatives.
AutoNDA by SimpleDocs
Points of Delivery. A. The Point(s) of Delivery of reclaimed water from the COUNTY to the USER is immediately downstream of the meter. The COUNTY shall own, operate, and maintain the reclaimed water distribution system upstream of the Point(s) of Delivery. The USER shall own, operate, and maintain all works downstream of the Point(s) of Delivery.
Points of Delivery. 3.1 The Point(s) of Delivery for all gas to be purchased hereunder shall be at Buyer's or Buyer's designee's meter at the following locations: LOCATION MAXIMUM INSTANTANEOUS RATES OF DELIVERY MAXIMUM OPERATING PRESSURE Primary: Xxxxxxx Processing Plant tailgate Meter #00-0000-00 San Xxxxxxxx County, Texas 100,000 MMBtu/day 650 psig* *See below Secondary: Xxxxxxx Xxxxxxxx Xxxxx #0000 Xxx Xxxxxxxx Xxxxxx, Texas 100,000 MMBtu/day 850 psig Except as provided below, all residue gas will be accepted by Buyer at the "Primary" Point of Delivery, and Buyer will cause the pressures at the Primary Point of Delivery not to exceed 650 psig. However. if, to the extent that, and only for so long as (i) the residue gas available under this Agreement exceeds Buyer's and all of its affiliates' gas requirements to supply their Ingleside Markets, or (ii) Buyer is unable to accept all of the residue gas at the Primary Point of Delivery due to an event of force majeure as provided in Section 11.1, then (iii) the pressure at the Primary Point of Delivery may increase to not more 850 psig and Buyer may also accept residue gas at the Point of Delivery designated "Secondary." Buyer will notify Seller of each event that causes Buyer to increase pressures at the Primary Point of Delivery or deliveries at the Secondary Point of Delivery, and the reasons therefor, as soon as reasonably practicable, and will again notify Seller upon the correction of the event.
Points of Delivery. Electric power and energy shall be delivered by Idaho Power at each point generally described as the load side terminals of the substation transformer 13.8 kilovolt disconnect switches at the Hoku Facility.