Pipeline design Sample Clauses

Pipeline design. Drilling of Xxxxx Preparation of areas and/or access routes to the location. Maritime and/or air transportation of personnel, Materials and/or equipment. Support services. Well drilling services. Performance of formation tests. Supplies and Materials. Well completion. Safety, Health and Environment Environmental impact studies. Prevention and detection of fire and gas leaks Treatment and disposal of residues. Environmental restoration. Safety audits. Environmental audit. [illegible signatures] Contract No. CNH-R01-L01-A7/2015 Petroleum Activity Petroleum Sub-activity Task Development General Technical economic evaluations. Contract administration. Development plan with detailed engineering. Administration, management of activities and general project expenses. Geophysical Detailed seismic reinterpretation. Seismic data processing and reprocessing. Geology Geological – petrophysical characterization of Reservoirs Geochemical analysis of samples. Stratigraphic studies Hydrocarbon analysis.
AutoNDA by SimpleDocs
Pipeline design. Provide consulting services for the design of water mains, transmission mains, siphons and associated appurtenances. Provide preliminary and final design services including the preparation of plans, specifications, and cost estimates. Provide bidding assistance, construction support, and final as-builts as needed for projects.
Pipeline design. CONSULTANT will prepare the Force main, Brine Pipeline, and 36" and 16 diameter water mains, including hydraulic analysis, plan and profiles, identify necessary manholes, blow-offs, relief valves, junction structures, air venting, pressure reducing stations, surge protection devices, other appurtenant facilities, Instrumentation, and recommendations for pipe material and joints. CONSULTANT will provide hydraulic profiles for minimum and maximum flows. CONSULTANT will provide hydraulic calculations pertaining to air/vacuum and air release valves, blow-off assemblies and other appurtenances that are required. CONSULTANT will provide site hydrologic and hydraulic calculations and structural design calculations for pipe supports. As part of the Thirty Percent design, the CONSULTANT will define construction staging requirements; spoil disposal requirements, and all supporting facilities and requirements including field office facilities and locations for the CITY. The CONSULTANT shall investigate and provide recommendations including the location and size of work areas, equipment and material storage, haul roads, equipment set up areas. Design of Morena Pump Station June 20, 2016 And Conveyance Pipelines (HI66635) A-20 EXHIBIT A CONSULTANT will provide a drawing index and table of contents for the contract documents including cover sheet, location map and index sheets, plans and profiles, structures, appurtenances, and details. Specification table of contents will include all known General Requirements and Technical Specifications titles. The Specifications for the pipelines shall be in conformance with the Standard Specifications for Public Works Construction format. The CONSULTANT shall comply with the requirements stated in attached checklist at each stage of the design submittals.
Pipeline design. CONSULTANT will prepare the pipeline design for both the North City to San Xxxxxxx and the North City to Miramar conveyance systems, including hydraulic analysis, plan and profiles, identify necessary manholes, blow-offs, relief valves, junction structures, air venting, pressure reducing stations, surge protection devices, other appurtenant facilities, Instrumentation, and recommendations for pipe material and joints. There are up to three (3) existing Pressure Reducing Stations (PRS) that are connected to the existing 36-inch recycled water line. The existing valves will be assessed; Operations and Maintenance records reviewed, and the manufacturer will be consulted to determine if the existing valves are suitable for service when the NCCS project is commissioned. It is anticipated that the existing valves can be used, however if they aren’t rated for the pressures required, they will be replaced during construction of the NCCS. CONSULTANT will provide hydraulic profiles for minimum and maximum flows. CONSULTANT will provide hydraulic calculations pertaining to air/vacuum and air release valves, blow-off assemblies and other appurtenances that are required. CONSULTANT will provide site hydrologic and hydraulic calculations and structural design calculations for pipe supports. As part of the Thirty Percent design, the CONSULTANT will define construction staging requirements; spoil disposal requirements, and all supporting facilities and requirements including field office facilities and locations for the CITY. The CONSULTANT shall investigate and provide recommendations including the location and size of work areas, equipment and material storage, haul roads, equipment set up areas. CONSULTANT will provide a drawing index and table of contents for the contract documents including cover sheet, location map and index sheets, plans and profiles, structures, appurtenances, and details. Specification table of contents will include all known General Requirements and Technical Specifications titles. The Table of Contents for the anticipated Specifications for the pipeline shall be in conformance with the Standard Specifications for Public Works Construction format.

Related to Pipeline design

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • Information Systems Acquisition Development and Maintenance Security of System Files. To protect City Information Processing Systems and system files containing information, Service Provider will ensure that access to source code is restricted to authorized users whose specific job function necessitates such access.

  • Testing-the-Waters Materials If at any time following the distribution of any Written Testing-the-Waters Communication there occurred or occurs an event or development as a result of which such Written Testing-the-Waters Communication included or would include an untrue statement of a material fact or omitted or would omit to state a material fact necessary in order to make the statements therein, in the light of the circumstances existing at that subsequent time, not misleading, the Company will promptly notify the Representatives and will promptly amend or supplement, at its own expense, such Written Testing-the-Waters Communication to eliminate or correct such untrue statement or omission.

  • Underground Storage Tanks In accordance with the requirements of Section 3(g) of the D.C. Underground Storage Tank Management Act of 1990, as amended by the District of Columbia Underground Storage Tank Management Act of 1990 Amendment Act of 1992 (D.C. Code § 8-113.01, et seq.) (collectively, the “UST Act”) and the applicable D.C. Underground Storage Tank Regulations, 20 DCMR Chapter 56 (the “UST Regulations”), District hereby informs the Developer that it has no knowledge of the existence or removal during its ownership of the Property of any “underground storage tanks” (as defined in the UST Act). Information pertaining to underground storage tanks and underground storage tank removals of which the D.C. Government has received notification is on file with the District Department of the Environment, Underground Storage Tank Branch, 00 X Xxxxxx, X.X., Xxxxx Xxxxx, Xxxxxxxxxx, X.X., 00000, telephone (000) 000-0000. District’s knowledge for purposes of this Section shall mean and be limited to the actual knowledge of Xxxxxx Xxxxx, Property Acquisition and Disposition Division of the Department of Housing and Community Development, telephone no. (000) 000-0000. The foregoing is set forth pursuant to requirements contained in the UST Act and UST Regulations and does not constitute a representation or warranty by District.

  • Storage Tanks If storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks. Notwithstanding anything to the contrary contained herein, Tenant shall have no right to use or install any underground storage tanks at the Project.

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

  • Condominiums/Planned Unit Developments If the Mortgaged Property is a condominium unit or a planned unit development (other than a de minimis planned unit development) such condominium or planned unit development project such Mortgage Loan was originated in accordance with, and the Mortgaged Property meets the guidelines set forth in the Originator's Underwriting Guidelines;

  • Scope of Work The Contractor has overall responsibility for and shall provide and furnish all materials, equipment, tools and labor as necessary or reasonably inferable to complete the Work, or any phase of the Work, in accordance with the Owner’s requirements and the terms of the Contract Documents.

Time is Money Join Law Insider Premium to draft better contracts faster.