OFFICE LIGHTING Sample Clauses

OFFICE LIGHTING. Furnish and install 2'x4' three lamp lay-in fluorescent light fixtures with standard acrylic lens (Lithonia Model # 2GT 3 32 A12 277 ES or approved equal)., and shall be wired to the 277/480 volt panel, 75 foot candles minimum at 3' A.F.F. or as permitted by code but no less than two (2) fixtures per 10’x12’ office. Wire one (1) light fixture near each exit door to provide 24 hour lighting.
AutoNDA by SimpleDocs
OFFICE LIGHTING. In open office area (20,000 SF), light fixtures shall be Verve II / Focal Point FV2S-SL3T8-1c-277 E-C24-TS4/TSS. This pendant fixture to be mounted 8'0” AFF in continuous rows on 7'0” centers. All other areas (5,000 SF) to have 2’ x 4’ recessed, high efficiency (Electronic Ballast) three lamp fixture with parabolic lens, 32 watt energy savings bulbs (T-8) shall be used. Light fixtures grid shall start a maximum of 2’ from any wall. Office lighting shall have a 75 foot candle minimum throughout the office area. One lighting contactor switch to turn on/off lighting shall be provided by office entrance. HVAC: Landlord will furnish and install roof top HVAC units with a standard system of distribution ducts. Supply registers and diffuses, return grills and associated fixtures servicing the office area (25,000 SF) and warehouse office area (4,000 SF). The design criteria shall be as to handle the heat load of the conditions of the building and 1 person per 75 SF in all office areas. All units shall be designed with a (7) day programmable thermostats. A separate 5 ton A/C cool only unit shall be provided for the Computer/Telephone room, supplied with a low ambient control module with auto restart.

Related to OFFICE LIGHTING

  • Moonlighting 24.01 The Company and the Union agree in principle to eliminate the practice commonly referred to as moonlighting.

  • Office Space Each employee shall be provided with office space which may be on a shared basis. The parties recognize the desirability of providing each employee with enclosed office space with a door lock, office equipment commensurate with assigned responsibilities, and ready access to a telephone. Each employee shall, consistent with building security, have reasonable access to the employee's office space and laboratories, studios, music rooms, and the like used in connection with assigned responsibilities; this provision may require that campus security provide access on an individual basis. Before an employee's office location is changed, or before there is a substantial alteration to an employee's office to a degree that impedes the employee's work effectiveness, the affected employee shall be notified, if practicable, at least one (1) month prior to such change.

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • Network Maintenance and Management 36.1 The Parties will work cooperatively to implement this Agreement. The Parties will exchange appropriate information (for example, maintenance contact numbers, network information, information required to comply with law enforcement and other security agencies of the Government, escalation processes, etc.) to achieve this desired result.

  • Office Space and Facilities The Adviser will arrange to furnish the Trust office space in the offices of the Adviser, or in such other place or places as may be agreed upon from time to time, and all necessary office facilities, simple business equipment, supplies, utilities and telephone service required for managing the investments of the Trust.

  • Connectivity User is solely responsible for providing and maintaining all necessary electronic communications with Exchange, including, wiring, computer hardware, software, communication line access, and networking devices.

  • Installation and Maintenance Except for the bi‐directional and production metering equipment owned by the City, all equipment on Customer’s side of the delivery point, including the required disconnect device, shall be provided and maintained in satisfactory operating condition by Customer and shall remain the property and responsibility of the Customer. The City will bear no responsibility for the installation or maintenance of Customer’s equipment or for any damage to property as a result of any failure or malfunction thereof. The City shall not be liable, directly or indirectly for permitting or continuing to allow the interconnection of the Facility or for the acts or omissions of Customer or the failure or malfunction of any equipment of Customer that causes loss or injury, including death, to any party.

  • Fitness Center Subject to the provisions of this Section, so long as Tenant is not in Default under this Lease, and provided Tenant’s employees execute a standard waiver of liability form used at the Fitness Center (hereinafter defined) and pay the applicable one time or monthly fee, then Tenant’s employees (the “Fitness Center Users”) shall be entitled to use the KINETIC fitness center (the “Fitness Center”) in the building located at 600 Xxxxxxx Xxxxxx Xxxxx, Xxxxxxx Xxxxx, Xxxxxxxxxx. The use of the Fitness Center shall be subject to the rules and regulations (including rules regarding hours of use) established from time to time by the Fitness Center operator. Landlord and Tenant acknowledge that the use of the Fitness Center by the Fitness Center Users shall be at their own risk. Tenant acknowledges that the provisions of this Section shall not be deemed to be a representation by Landlord that the Fitness Center (or any other fitness facility) shall be continuously operated and maintained throughout the Term of this Lease, and no termination of Tenant’s or the Fitness Center Users’ rights to the Fitness Center shall entitle Tenant to an abatement or reduction in Basic Rent, constitute a constructive eviction, or result in an event of default by Landlord under this Lease. Tenant hereby voluntarily releases, discharges, waives and relinquishes any and all actions or causes of action for personal injury or property damage occurring to Tenant or its employees or agents arising as a result of the use of the Fitness Center, or any activities incidental thereto, wherever or however the same may occur, and further agrees that Tenant will not prosecute any claim for personal injury or property damage against Landlord or any of its officers, agents, servants or employees for any said causes of action. It is the intention of Tenant with respect to the Fitness Center to exempt and relieve Landlord from liability for personal injury or property damage caused by negligence. Tenant’s rights hereunder to permit its employees to use the Fitness Center shall belong solely to Tenant and may not be transferred or assigned without Landlord’s prior written consent, which may be withheld by Landlord in Landlord’s sole discretion.

  • Office Location During the Term, the Executive's services hereunder shall be performed at the offices of the Company, which shall be within a twenty five (25) mile radius of New York, NY, subject to necessary travel requirements to the Company’s offices in Toronto, Canada and other MDC Group company locations in order to carry out his duties in connection with his position hereunder.

  • Installation Services 3.1 The Bitstream 2a Service includes a Standard Install as set out below (in each case to the extent that the relevant provisioning works are not already complete for the relevant Service Order).1

Time is Money Join Law Insider Premium to draft better contracts faster.