Main Steam Flow Capacity Test Sample Clauses

Main Steam Flow Capacity Test. As part of Unit 6 Performance Testing, a *** will be performed to assure that Unit 6 can achieve this steam flow operating condition on a continuous basis. Although not specifically addressed in ASME PTC 46, the Main Steam Flow Capacity will be verified using the ASME PTC 46 governed Unit 6 Performance Test instrumentation and calibration methods, except where approved by the Owner. • The test duration will be an 8 hour continuous run. • Fuel and sorbent corrections will not be applied unless outside the range of the Agreement specified design range for these materials. • Condenser exhaust pressure will be controlled as close as possible to ***. by operation of the cooling tower fans. Corrections will be made to adjust results to ***. • Equipment will not exceed EPC Agreement (Exhibit A) or Manufacturer ratings. • Spare/redundant equipment shall not be operated, these include, but are not limited to: • Spare hotwell and condensate booster pumps • Spare pulverizer, unless allowed by Steam Generator guarantee • Spare closed cooling water pump and heat exchanger • Spare limestone ball mill • Spare gypsum dewatering train Contractor shall report test results for the *** and the corresponding net electrical output (which is not guaranteed for this test). Net electrical output shall be corrected to Base Performance Conditions for power factor, and wet bulb.
AutoNDA by SimpleDocs

Related to Main Steam Flow Capacity Test

  • Limited Capacity of Escrow Agent This Agreement expressly and exclusively sets forth the duties of Escrow Agent with respect to any and all matters pertinent hereto, and no implied duties or obligations shall be read into this Agreement against Escrow Agent. Escrow Agent acts hereunder as an escrow agent only and is not associated, affiliated, or involved in the business decisions or business activities of Issuer, portal, or Subscriber. Escrow Agent is not responsible or liable in any manner whatsoever for the sufficiency, correctness, genuineness, or validity of the subject matter of this Agreement or any part thereof, or for the form of execution thereof, or for the identity or authority of any person executing or depositing such subject matter. Escrow Agent shall be under no duty to investigate or inquire as to the validity or accuracy of any document, agreement, instruction, or request furnished to it hereunder, including, without limitation, the authority or the identity of any signer thereof, believed by it to be genuine, and Escrow Agent may rely and act upon, and shall not be liable for acting or not acting upon, any such document, agreement, instruction, or request. Escrow Agent shall in no way be responsible for notifying, nor shall it be responsible to notify, any party thereto or any other party interested in this Agreement of any payment required or maturity occurring under this Agreement or under the terms of any instrument deposited herewith. Escrow Agent’s entire liability, and Broker and Issuer’s exclusive remedy, in any cause of action based on contract, tort, or otherwise in connection with any services furnished pursuant to this Agreement shall be limited to the total fees paid to Escrow Agent by Issuer. The Escrow Agent shall not be called upon to advise any party as to the wisdom in selling or retaining or taking or refraining from any action with respect to any securities or other property deposited hereunder. Escrow Agent may consult legal counsel selected by it in the event of any dispute or question as to the construction of any of the provisions hereof or of any other agreement or of its duties hereunder, or relating to any dispute involving any party hereto, and shall incur no liability and shall be fully indemnified from any reasonable liability whatsoever in acting in accordance with the opinion or instruction of such counsel. Issuer shall promptly pay, upon demand, the reasonable fees and expenses of any such counsel.

  • Stability Testing Patheon may be requested to conduct stability testing on the Products in accordance with the protocols set out in the Specifications for the separate fees and during the time periods set out in Schedule C to a Product Agreement. Patheon will not make any changes to these testing protocols without prior written approval from Client. If a confirmed stability test failure occurs, Patheon will notify Client within one Business Day, after which Patheon and Client will jointly determine the proceedings and methods to be undertaken to investigate the cause of the failure, including which party will bear the cost of the investigation. Patheon will not be liable for these costs unless it has failed to perform the Manufacturing Services in accordance with the Specifications, cGMPs, and Applicable Laws. Patheon will give Client ail stability test data and results at Client’s request.

  • Mission Payload The payload for a stage length of [*] nautical miles in still air (equivalent to a distance of [*] nautical miles with a [*] wind, representative of a [*] route in [*]) using the conditions and operating rules defined below, shall not be less than the following guarantee value: NOMINAL: [*]0 Kilograms TOLERANCE: [*] Kilograms GUARANTEE: [*] Kilograms

  • Capacity as Lender The Person serving as the Administrative Agent hereunder shall have the same rights and powers in its capacity as a Lender as any other Lender and may exercise the same as though it were not the Administrative Agent, and such Person and its Affiliates may accept deposits from, lend money to and generally engage in any kind of business with the Borrower or any Subsidiary or other Affiliate thereof as if it were not the Administrative Agent hereunder.

  • Facility Type    Call Sign    Exp Date TV Broadcast Station License WBRE-TV 08/01/2007 (Channel 28, Xxxxxx-Xxxxx, Pennsylvania) DTV Facility WBRE-DT 08/01/2007 (Channel 11, Xxxxxx-Xxxxx, Pennsylvania) TV Translator Station License W24BL 08/01/2007 TV Translator Station License W30AN 08/01/2007 TV Translator Station License W51BP 08/01/2007 TV Translator Station License W64AL 08/01/2007 Transmit-Only Earth Station License E910642 11/01/2011 Transmit-Receive Earth Station License E020058 05/03/2017 TV Pickup KA35201 08/01/2007 TV Pickup KA35245 08/01/2007 TV Pickup KA74870 08/01/2007 TV Pickup KC62824 08/01/2007 Broadcast Auxiliary KF5726 08/01/2007 TV Studio Transmitter Link KGH66 08/01/2007 R/P Base Mobile System KGU973 08/01/2007 TV Pickup KK4138 08/01/2007 TV Pickup KL2535 08/01/2007 TV Pickup KP4407 08/01/2007 R/P Base Mobile System KQB618 08/01/2007 TV Pickup KR7688 08/01/2007 TV Pickup KR7693 08/01/2007 TV Pickup KR7771 08/01/2007 TV Pickup KS2001 08/01/2007 TV Pickup KY2899 08/01/2007 R/P Mobile KY5608 08/01/2007 TV Studio Transmitter Link KZO21 08/01/2007 TV Intercity Relay WFW575 08/01/2007 TV Intercity Relay WGI290 08/01/2007 TV Intercity Relay WHB674 08/01/2007 TV Intercity Relay WLI324 08/01/2007 TV Intercity Relay WLI325 08/01/2007 TV Intercity Relay WLI337 08/01/2007 TV Intercity Relay WMF322 08/01/2007 TV Intercity Relay WMF323 08/01/2007

  • BUSINESS CONTINUITY/DISASTER RECOVERY In the event of equipment failure, work stoppage, governmental action, communication disruption or other impossibility of performance beyond State Street’s control, State Street shall take reasonable steps to minimize service interruptions. Specifically, State Street shall implement reasonable procedures to prevent the loss of data and to recover from service interruptions caused by equipment failure or other circumstances with resumption of all substantial elements of services in a timeframe sufficient to meet business requirements. State Street shall enter into and shall maintain in effect at all times during the term of this Agreement with appropriate parties one or more agreements making reasonable provision for (i) periodic back-up of the computer files and data with respect to the Trusts; and (ii) emergency use of electronic data processing equipment to provide services under this Agreement. State Street shall test the ability to recover to alternate data processing equipment in accordance with State Street program standards, and provide a high level summary of business continuity test results to the Trusts upon request. State Street will remedy any material deficiencies in accordance with State Street program standards. Upon reasonable advance notice, and at no cost to State Street, the Trusts retain the right to review State Street’s business continuity, crisis management, disaster recovery, and third-party vendor management processes and programs (including discussions with the relevant subject matter experts and an on-site review of the production facilities used) related to delivery of the service no more frequently than an annual basis. Upon reasonable request, the State Street also shall discuss with senior management of the Trusts any business continuity/disaster recovery plan of the State Street and/or provide a high-level presentation summarizing such plan.”

  • Representative Capacity; Nonrecourse Obligations A COPY OF THE DECLARATION OF TRUST OR OTHER ORGANIZATIONAL DOCUMENT OF EACH FUND IS ON FILE WITH THE SECRETARY OF THE STATE OF THE FUND'S FORMATION, AND NOTICE IS HEREBY GIVEN THAT THIS AGREEMENT IS NOT EXECUTED ON BEHALF OF THE TRUSTEES OF ANY FUND AS INDIVIDUALS, AND THE OBLIGATIONS OF THIS AGREEMENT ARE NOT BINDING UPON ANY OF THE TRUSTEES, OFFICERS, SHAREHOLDERS OR PARTNERS OF ANY FUND INDIVIDUALLY, BUT ARE BINDING ONLY UPON THE ASSETS AND PROPERTY OF EACH FUND'S RESPECTIVE PORTFOLIOS. THE CUSTODIAN AGREES THAT NO SHAREHOLDER, TRUSTEE, OFFICER OR PARTNER OF ANY FUND MAY BE HELD PERSONALLY LIABLE OR RESPONSIBLE FOR ANY OBLIGATIONS OF ANY FUND ARISING OUT OF THIS AGREEMENT.

  • Emergency Generator Tenant shall have the right to tie into and use the emergency generator to be installed by Landlord as part of the Base Building Work for use by tenants of the Unit (the “Unit Generator”). Tenant shall be responsible, at its sole cost and expense, for installing, maintaining, repairing and replacing its connection between the Premises and the Unit Generator, and all associated cabling. Tenant shall be permitted to use up to an average of three (3) xxxxx per square foot of usable area in the Premises from the Unit Generator, and at no time shall Tenant exceed that use limitation with respect to the Unit Generator. Except to the extent that Tenant ties into the Unit Generator as part of the Initial Tenant Work in accordance with the provisions of the Work Letter, installation of such tie-in and any related cabling, conduit and appurtenances will be governed by the applicable provisions of this Lease relating to Tenant Work. Tenant will submit to Landlord at least thirty (30) days prior to the proposed installation date Tenant’s proposed plans and specifications relating to the tie-in to the Unit Generator and all associated lines. Tenant may not commence any work to tie into the Unit Generator until it has received Landlord’s prior written approval (not to be unreasonably withheld, delayed or conditioned) of such plans and specifications. Tenant, at its sole cost and expense, shall comply with all applicable Legal Requirements and Title Matters and Landlord’s reasonable directives relating to the installation, operation, maintenance and repair of such tie-in, including (i) obtaining and maintaining (or causing to be obtained and maintained) and complying with the provisions of all applicable permits relating to the tie into and use of the Unit Generator. Tenant may not use the Unit Generator for any purpose other than solely in connection with Tenant’s occupancy of the Premises for the Permitted Use and in accordance with any applicable permit(s) pertaining to the Unit Generator. Except for permitted subtenants and assignees. Tenant may not use the Unit Generator to serve other occupant(s) of the Development.

  • Floor Load Tenant shall not place a load upon any floor of the Premises that exceeds 50 pounds per square foot “live load”. Landlord reserves the right to reasonably designate the position of all Equipment which Tenant wishes to place within the Premises, and to place limitations on the weight thereof.

  • Power and Capacity Each Shareholder has the power, authority and capacity to enter into this Agreement and to consummate the transactions contemplated hereby. This Agreement constitutes each Shareholders’s valid, legal and binding obligation and is enforceable against such Shareholder in accordance with its terms, subject, however, as to enforcement, to bankruptcy, insolvency, fraudulent transfer, moratorium and similar laws of general applicability relating to or affecting creditors’ rights; SUNO — Corporate Status and Capacity

Time is Money Join Law Insider Premium to draft better contracts faster.