Liquid Measurement Sample Clauses

Liquid Measurement. COPANO shall measure Products and condensate by utilizing meters operated and maintained in accordance with recognized industry standards. Measurement procedures and calculations will be in accordance with the API Manual of Petroleum Measurement. Meter tests and calibration will be conducted as determined by COPANO, but at least once each month. Procedures used in testing and calibration will be in accordance with the aforementioned API Manual of Petroleum Measurement to ensure measurement accuracy to within one-half of one percent. Consecutive meter factors differing by more than 50/10,000 will result in an adjustment to recorded volumes. KMTP shall have access to the measuring equipment at all reasonable times, but readings, calibrations and adjustments thereof shall be done by employees or agents of COPANO. COPANO shall notify KMTP in advance of the performance of tests and calibrations so that KMTP may have its representative present as a witness.
AutoNDA by SimpleDocs
Liquid Measurement. Eagle Ford, or its designee, shall measure Plant Products by utilizing meters operated and maintained in accordance with recognized industry standards. Measurement procedures and calculations will be in accordance with the API Manual of Petroleum Measurement. Meter tests and calibration will be conducted as determined by Eagle Ford, but at least once each Month. Procedures used in testing and calibration will be in accordance with the aforementioned API Manual of Petroleum Measurement to ensure measurement accuracy to within one-half of one percent. Consecutive meter factors differing by more than 50/10,000 will result in an adjustment to recorded volumes. The readings, calibrations and adjustments of the measuring equipment shall be done by employees or agents of Eagle Ford. Eagle Ford shall notify Customer in advance of the performance of tests and calibrations so that Customer may have its representative present as a witness at the Points of Delivery.

Related to Liquid Measurement

  • Usage Measurement Usage measurement for calls shall begin when answer supervision or equivalent Signaling System 7 (SS7) message is received from the terminating office and shall end at the time of call disconnect by the calling or called subscriber, whichever occurs first.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point Xxxxxx. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • Measurement Should the State terminate this contract as herein provided, no fees other than fees due and payable at the time of termination shall thereafter be paid to the Engineer. In determining the value of the work performed by the Engineer prior to termination, the State shall be the sole judge. Compensation for work at termination will be based on a percentage of the work completed at that time. Should the State terminate this contract under paragraph (4) or (5) above, the Engineer shall not incur costs during the thirty-day notice period in excess of the amount incurred during the preceding thirty days.

  • Performance Measurement Satisfactory performance of this Contract will be measured by:

  • PERFORMANCE MEASUREMENTS Upon a particular Commission’s issuance of an Order pertaining to Performance Measurements in a proceeding expressly applicable to all CLECs generally, BellSouth shall implement in that state such Performance Measurements as of the date specified by the Commission. Performance Measurements that have been Ordered in a particular state can currently be accessed via the internet at xxxx://xxxx.xxxxxxxxx.xxx. The following Service Quality Measurements (SQM) plan as it presently exists and as it may be modified in the future, is being included as the performance measurements currently in place for the state of Tennessee. At such time that the TRA issues a subsequent Order pertaining to Performance Measurements, such Performance Measurements shall supersede the SQM contained in the Agreement. BellSouth Service Quality Measurement Plan‌ (SQM) Tennessee Performance Metrics Measurement Descriptions Version 2.00 Issue Date: July 1, 2003 Introduction

  • Measuring EPP parameters Every 5 minutes, EPP probes will select one “IP address” of the EPP servers of the TLD being monitored and make an “EPP test”; every time they should alternate between the 3 different types of commands and between the commands inside each category. If an “EPP test” result is undefined/unanswered, the EPP service will be considered as unavailable from that probe until it is time to make a new test.

  • Measuring DNS parameters Every minute, every DNS probe will make an UDP or TCP “DNS test” to each of the public-­‐DNS registered “IP addresses” of the name servers of the domain name being monitored. If a “DNS test” result is undefined/unanswered, the tested IP will be considered unavailable from that probe until it is time to make a new test.

  • Performance Measure The specific representation of a process or outcome that is relevant to the assessment of performance; it is quantifiable and can be documented

  • Method of Measurement The emission of voltage changes, voltage fluctuations and flicker on AC power lines generated by the vehicle representative of its type shall be measured using the method described in Annex 12. The method of measurement shall be defined by the vehicle manufacturer in accordance with the Technical Service.

Time is Money Join Law Insider Premium to draft better contracts faster.