{"component": "clause", "props": {"groups": [{"snippet": "Contractor shall provide all engineering and design services necessary for completion of the Project in conformity with this Agreement, including but not limited to (a) preparation of (i) the Project Design Book which shall form the basis of the design of the Project, (ii) conceptual design, and (iii) engineering and design necessary to describe and detail the Project and to optimize the Project heat balance, (b) provision of criteria for the detailed design by suppliers of equipment, materials and systems for incorporation into the Project, and (c) preparation of drawings, plans, bills of material, schedules and estimates. Contractor shall comply with the Electrical Interconnection Requirements and cooperate with the engineering efforts and otherwise accommodate the interface requirements of the Utility, the Fuel Supplier, all federal, state and local agencies, and all utilities serving the Project that are consistent with Prudent Utility Practices; provided, however, that in the event that such accommodation would require Contractor to perform studies or other tasks that are a material addition to the Services otherwise provided for in this Agreement, Contractor shall not be required to perform such material additional work hereunder unless a Scope Change Order has been issued by Owner with respect thereto in accordance with Article 12 hereof. Upon Owner's request, Contractor shall use all reasonable efforts to provide Owner and, at Owner's request, the Independent Engineer and the Utility with reasonable access to meetings between Contractor and its architects, engineers or Subcontractors regarding the construction of the Project (except to the extent such meetings involve contractual matters that do not substantially affect or relate to the performance of the Services hereunder), provided such access does not materially interfere with the progress of Contractor's work hereunder. Contractor agrees to timely provide Owner and, at Owner's request, the Independent Engineer and the Utility with such documents and other information as are reasonably necessary for the Independent Engineer and the Utility to review and evaluate the design of the Project. Without limitation to the foregoing, Contractor agrees to submit to Owner and the Utility the design for the Electrical Interconnection Facilities (or any addition, modification or replacement thereto) in a timely manner in accordance with Section 2.1.8.1 hereof so as to enable Owner to obtain the Utility's approval thereof in accordance with the requirements of", "size": 6, "snippet_links": [{"key": "contractor-shall-provide", "type": "clause", "offset": [0, 24]}, {"key": "engineering-and-design-services", "type": "clause", "offset": [29, 60]}, {"key": "necessary-for", "type": "definition", "offset": [61, 74]}, {"key": "completion-of-the-project", "type": "definition", "offset": [75, 100]}, {"key": "conformity-with", "type": "clause", "offset": [104, 119]}, {"key": "not-limited", "type": "clause", "offset": [150, 161]}, {"key": "project-design-book", "type": "definition", "offset": [192, 211]}, {"key": "basis-of", "type": "clause", "offset": [233, 241]}, {"key": "design-of-the-project", "type": "clause", "offset": [246, 267]}, {"key": "conceptual-design", "type": "definition", "offset": [274, 291]}, {"key": "provision-of", "type": "clause", "offset": [417, 429]}, {"key": "the-detailed-design", "type": "clause", "offset": [443, 462]}, {"key": "preparation-of-drawings", "type": "clause", "offset": [556, 579]}, {"key": "comply-with-the", "type": "clause", "offset": [649, 664]}, {"key": "interconnection-requirements", "type": "clause", "offset": [676, 704]}, {"key": "cooperate-with", "type": "clause", "offset": [709, 723]}, {"key": "requirements-of-the", "type": "clause", "offset": [788, 807]}, {"key": "fuel-supplier", "type": "definition", "offset": [821, 834]}, {"key": "local-agencies", "type": "clause", "offset": [859, 873]}, {"key": "all-utilities", "type": "clause", "offset": [879, 892]}, {"key": "consistent-with", "type": "definition", "offset": [922, 937]}, {"key": "prudent-utility-practices", "type": "clause", "offset": [938, 963]}, {"key": "in-the-event", "type": "clause", "offset": [989, 1001]}, {"key": "contractor-to", "type": "clause", "offset": [1040, 1053]}, {"key": "other-tasks", "type": "clause", "offset": [1073, 1084]}, {"key": "to-the-services", "type": "clause", "offset": [1114, 1129]}, {"key": "in-this-agreement", "type": "definition", "offset": [1153, 1170]}, {"key": "material-additional-work", "type": "definition", "offset": [1221, 1245]}, {"key": "scope-change-order", "type": "definition", "offset": [1265, 1283]}, {"key": "by-owner", "type": "definition", "offset": [1300, 1308]}, {"key": "in-accordance-with", "type": "clause", "offset": [1330, 1348]}, {"key": "article-12", "type": "definition", "offset": [1349, 1359]}, {"key": "all-reasonable-efforts", "type": "clause", "offset": [1411, 1433]}, {"key": "to-provide", "type": "clause", "offset": [1434, 1444]}, {"key": "the-independent-engineer", "type": "clause", "offset": [1476, 1500]}, {"key": "access-to", "type": "definition", "offset": [1533, 1542]}, {"key": "construction-of-the-project", "type": "clause", "offset": [1633, 1660]}, {"key": "except-to-the-extent", "type": "clause", "offset": [1662, 1682]}, {"key": "contractual-matters", "type": "clause", "offset": [1705, 1724]}, {"key": "substantially-affect", "type": "definition", "offset": [1737, 1757]}, {"key": "relate-to", "type": "definition", "offset": [1761, 1770]}, {"key": "performance-of-the-services", "type": "clause", "offset": [1775, 1802]}, {"key": "of-contractor", "type": "clause", "offset": [1884, 1897]}, {"key": "contractor-agrees-to", "type": "clause", "offset": [1916, 1936]}, {"key": "documents-and-other-information", "type": "clause", "offset": [2034, 2065]}, {"key": "reasonably-necessary", "type": "clause", "offset": [2073, 2093]}, {"key": "the-foregoing", "type": "definition", "offset": [2211, 2224]}, {"key": "to-owner", "type": "definition", "offset": [2254, 2262]}, {"key": "electrical-interconnection-facilities", "type": "definition", "offset": [2298, 2335]}, {"key": "in-a-timely-manner", "type": "definition", "offset": [2391, 2409]}, {"key": "the-requirements", "type": "clause", "offset": [2534, 2550]}], "samples": [{"hash": "7S3pqVPn6F6", "uri": "/contracts/7S3pqVPn6F6#engineering-and-design", "label": "Engineering, Procurement and Construction Services Agreement (Aes Ironwood LLC)", "score": 18.0, "published": true}, {"hash": "4frtOfVenCK", "uri": "/contracts/4frtOfVenCK#engineering-and-design", "label": "Engineering, Procurement and Construction Services Agreement (Aes Ironwood LLC)", "score": 18.0, "published": true}, {"hash": "2qd3p0ayVZG", "uri": "/contracts/2qd3p0ayVZG#engineering-and-design", "label": "Engineering, Procurement and Construction Services Agreement (Aes Ironwood LLC)", "score": 18.0, "published": true}], "hash": "209acf495f7d9d865f386fb022ea33b3", "id": 3}, {"snippet": "The Developer is responsible for preparing the engineering design work. All engineering design work must comply with the Applicable Reliability Standards, in addition to all relevant guidelines and design standards, including, but not limited to: \u2022 ANSI C2-2017 National Electrical Safety Code \u2022 ASCE 48 Design of Steel Transmission Pole Structures \u2022 IEEE Std. 524 Guide to the Installation of Overhead Transmission Line Conductors \u2022 IEEE Std. 691 Guide for Transmission Structure Foundation Design and Testing \u2022 NYPP Tie-Line Ratings Task Force 1995 Report \u2022 ASCE Manual of Practice 113 Substation Structure Design Guide \u2022 IEEE Std. 80 Guide for Safety in AC Substation Grounding \u2022 ANSI C37, Standards Series for substations and circuit breakers \u2022 ANSI C57, Standards Series for power and Instrument Transformers \u2022 IEEE and ANSI standards for transmission lines and substations, as applicable. \u2022 National Grid, Con Edison, Orange & Rockland, Central \u2587\u2587\u2587\u2587\u2587\u2587, NYSEG, NYPA, and Affected Transmission Owners local transmission design criteria, as applicable.", "size": 19, "snippet_links": [{"key": "the-developer", "type": "clause", "offset": [0, 13]}, {"key": "responsible-for", "type": "clause", "offset": [17, 32]}, {"key": "design-work", "type": "clause", "offset": [59, 70]}, {"key": "applicable-reliability-standards", "type": "clause", "offset": [121, 153]}, {"key": "in-addition-to", "type": "clause", "offset": [155, 169]}, {"key": "design-standards", "type": "definition", "offset": [198, 214]}, {"key": "not-limited", "type": "clause", "offset": [231, 242]}, {"key": "national-electrical-safety-code", "type": "definition", "offset": [262, 293]}, {"key": "transmission-pole", "type": "definition", "offset": [320, 337]}, {"key": "installation-of", "type": "clause", "offset": [378, 393]}, {"key": "overhead-transmission-line", "type": "clause", "offset": [394, 420]}, {"key": "foundation-design", "type": "clause", "offset": [481, 498]}, {"key": "task-force", "type": "definition", "offset": [535, 545]}, {"key": "design-guide", "type": "definition", "offset": [609, 621]}, {"key": "for-safety", "type": "clause", "offset": [643, 653]}, {"key": "substation-grounding", "type": "clause", "offset": [660, 680]}, {"key": "circuit-breakers", "type": "clause", "offset": [730, 746]}, {"key": "instrument-transformers", "type": "clause", "offset": [790, 813]}, {"key": "transmission-lines", "type": "clause", "offset": [844, 862]}, {"key": "national-grid", "type": "clause", "offset": [897, 910]}, {"key": "con-edison", "type": "definition", "offset": [912, 922]}, {"key": "transmission-owners", "type": "definition", "offset": [985, 1004]}, {"key": "design-criteria", "type": "clause", "offset": [1024, 1039]}], "samples": [{"hash": "5xrPrmno9r5", "uri": "/contracts/5xrPrmno9r5#engineering-and-design", "label": "Development Agreement", "score": 29.1857452393, "published": true}, {"hash": "8iUcRy0WTrN", "uri": "/contracts/8iUcRy0WTrN#engineering-and-design", "label": "Service Agreement", "score": 29.0570888519, "published": true}, {"hash": "gbDbKSZXbT2", "uri": "/contracts/gbDbKSZXbT2#engineering-and-design", "label": "Development Agreement", "score": 27.1857452393, "published": true}], "hash": "24bc6ff2727c05adc4f18d1c18875df7", "id": 1}, {"snippet": "The Developer is responsible for preparing the engineering design work. All engineering design work must comply with the Applicable Reliability Standards, in addition to all relevant guidelines and design standards, including, but not limited to: \u2022 ANSI C2-2017 National Electrical Safety Code \u2022 ASCE 48 Design of Steel Transmission Pole Structures \u2022 IEEE Std. 524 Guide to the Installation of Overhead Transmission Line Conductors \u2022 IEEE Std. 691 Guide for Transmission Structure Foundation Design and Testing \u2022 NYPP Tie-Line Ratings Task Force 1995 Report \u2022 ASCE Manual of Practice 113 Substation Structure Design Guide \u2022 IEEE Std. 80 Guide for Safety in AC Substation Grounding \u2022 ANSI C37, Standards Series for substations and circuit breakers \u2022 ANSI C57, Standards Series for power and Instrument Transformers \u2022 IEEE and ANSI standards for transmission lines and substations as applicable", "size": 8, "snippet_links": [{"key": "the-developer", "type": "clause", "offset": [0, 13]}, {"key": "responsible-for", "type": "clause", "offset": [17, 32]}, {"key": "design-work", "type": "clause", "offset": [59, 70]}, {"key": "applicable-reliability-standards", "type": "clause", "offset": [121, 153]}, {"key": "in-addition-to", "type": "clause", "offset": [155, 169]}, {"key": "design-standards", "type": "definition", "offset": [198, 214]}, {"key": "not-limited", "type": "clause", "offset": [231, 242]}, {"key": "national-electrical-safety-code", "type": "definition", "offset": [262, 293]}, {"key": "transmission-pole", "type": "definition", "offset": [320, 337]}, {"key": "installation-of", "type": "clause", "offset": [378, 393]}, {"key": "overhead-transmission-line", "type": "clause", "offset": [394, 420]}, {"key": "foundation-design", "type": "clause", "offset": [481, 498]}, {"key": "task-force", "type": "definition", "offset": [535, 545]}, {"key": "design-guide", "type": "definition", "offset": [609, 621]}, {"key": "for-safety", "type": "clause", "offset": [643, 653]}, {"key": "substation-grounding", "type": "clause", "offset": [660, 680]}, {"key": "circuit-breakers", "type": "clause", "offset": [730, 746]}, {"key": "instrument-transformers", "type": "clause", "offset": [790, 813]}, {"key": "transmission-lines", "type": "clause", "offset": [844, 862]}], "samples": [{"hash": "iuaV2s7JTMJ", "uri": "/contracts/iuaV2s7JTMJ#engineering-and-design", "label": "Development Agreement", "score": 34.923412323, "published": true}, {"hash": "1V6PDUqLl18", "uri": "/contracts/1V6PDUqLl18#engineering-and-design", "label": "Development Agreement", "score": 34.8247718811, "published": true}, {"hash": "bmlxy0fZaOB", "uri": "/contracts/bmlxy0fZaOB#engineering-and-design", "label": "Development Agreement", "score": 34.818572998, "published": true}], "hash": "c2fa2705803bff27fbe6385cd5b4d387", "id": 2}, {"snippet": "7 6.1 Grantor's Obligations...........................................................................7 6.2 Grantee's Obligations...........................................................................8", "size": 5, "snippet_links": [], "samples": [{"hash": "j9zmlAtLOCj", "uri": "/contracts/j9zmlAtLOCj#engineering-and-design", "label": "Agreement for the Provision of Fiber Optic Facilities and Services (Northeast Optic Network Inc)", "score": 18.0, "published": true}, {"hash": "6JSs7dccR0J", "uri": "/contracts/6JSs7dccR0J#engineering-and-design", "label": "Agreement for the Provision of Fiber Optic Facilities and Services (Northeast Optic Network Inc)", "score": 18.0, "published": true}], "hash": "f111334d7c1c3ec4ada727721c898492", "id": 5}, {"snippet": "The Developer may elect to have the proposed extension designed by a duly registered Washington engineer of its own choosing, or by the District. Systems designed by persons other than the District must be reviewed and approved by the District before construction may commence on the extension. The District services in designing a system, or reviewing a system designed by the Developer\u2019s engineer, are a cost to the District within the construction fee.", "size": 5, "snippet_links": [{"key": "the-proposed", "type": "clause", "offset": [32, 44]}, {"key": "duly-registered", "type": "clause", "offset": [69, 84]}, {"key": "by-the-district", "type": "clause", "offset": [129, 144]}, {"key": "approved-by", "type": "clause", "offset": [219, 230]}, {"key": "before-construction", "type": "clause", "offset": [244, 263]}, {"key": "district-services", "type": "clause", "offset": [299, 316]}, {"key": "by-the-developer", "type": "clause", "offset": [371, 387]}, {"key": "cost-to-the-district", "type": "clause", "offset": [406, 426]}, {"key": "construction-fee", "type": "clause", "offset": [438, 454]}], "samples": [{"hash": "epewjrrakfi", "uri": "/contracts/epewjrrakfi#engineering-and-design", "label": "Construction Agreement", "score": 30.1055011749, "published": true}, {"hash": "g1PXYyOjqYB", "uri": "/contracts/g1PXYyOjqYB#engineering-and-design", "label": "Construction Agreement", "score": 24.975358963, "published": true}, {"hash": "4lly1lQxX19", "uri": "/contracts/4lly1lQxX19#engineering-and-design", "label": "Construction Agreement", "score": 24.0212192535, "published": true}], "hash": "ca137c5721f11d485d8e015ad6f94bf4", "id": 4}, {"snippet": "The Designated Entity is responsible for preparing the engineering design work. All engineering design work must comply with the Applicable Reliability Standards, in addition to all relevant guidelines and design standards, including, but not limited to: \u2022 ANSI C2-2023 National Electrical Safety Code; \u2022 New York Transmission Owners Task Force on Tie-Line Ratings Report 2019; \u2022 ASCE Manual of Practice 113 Substation Structure Design Guide; \u2022 IEEE Std. 80 Guide for Safety in AC Substation Grounding; \u2022 IEEE C37, Standard for substations and circuit breakers; \u2022 IEEE C57, Standard for power and transformers; and \u2022 IEEE and ANSI standards for transmission lines and substations, as applicable.", "size": 4, "snippet_links": [{"key": "designated-entity", "type": "clause", "offset": [4, 21]}, {"key": "responsible-for", "type": "clause", "offset": [25, 40]}, {"key": "design-work", "type": "clause", "offset": [67, 78]}, {"key": "applicable-reliability-standards", "type": "clause", "offset": [129, 161]}, {"key": "in-addition-to", "type": "clause", "offset": [163, 177]}, {"key": "design-standards", "type": "definition", "offset": [206, 222]}, {"key": "not-limited", "type": "clause", "offset": [239, 250]}, {"key": "national-electrical-safety-code", "type": "definition", "offset": [270, 301]}, {"key": "new-york", "type": "clause", "offset": [305, 313]}, {"key": "transmission-owners", "type": "definition", "offset": [314, 333]}, {"key": "task-force", "type": "definition", "offset": [334, 344]}, {"key": "design-guide", "type": "definition", "offset": [429, 441]}, {"key": "for-safety", "type": "clause", "offset": [464, 474]}, {"key": "substation-grounding", "type": "clause", "offset": [481, 501]}, {"key": "circuit-breakers", "type": "clause", "offset": [544, 560]}, {"key": "transmission-lines", "type": "clause", "offset": [645, 663]}], "samples": [{"hash": "aOpnwpIHS7j", "uri": "/contracts/aOpnwpIHS7j#engineering-and-design", "label": "Service Agreement", "score": 33.3988952637, "published": true}, {"hash": "8MMih7ZAwNg", "uri": "/contracts/8MMih7ZAwNg#engineering-and-design", "label": "Development Agreement", "score": 31.7651958466, "published": true}, {"hash": "fvT0fY229we", "uri": "/contracts/fvT0fY229we#engineering-and-design", "label": "Development Agreement", "score": 31.5720844269, "published": true}], "hash": "2125f7455a9bde1af528a9218e0750a8", "id": 6}, {"snippet": "The Designated Entity is responsible for preparing the engineering design work. All engineering design work must comply with the Applicable Reliability Requirements, in addition to all relevant guidelines and design standards, including, but not limited to: \u2022 ANSI C2-2023 National Electrical Safety Code \u2022 ASCE Manual of Practice 113 Substation Structure Design Guide \u2022 IEEE Std. 80 Guide for Safety in AC Substation Grounding \u2022 IEEE C37, Standard for substations and circuit breakers \u2022 IEEE C57, Standard for power and transformers \u2022 IEEE and ANSI standards for transmission lines and substations, as applicable", "size": 4, "snippet_links": [{"key": "designated-entity", "type": "clause", "offset": [4, 21]}, {"key": "responsible-for", "type": "clause", "offset": [25, 40]}, {"key": "design-work", "type": "clause", "offset": [67, 78]}, {"key": "applicable-reliability-requirements", "type": "definition", "offset": [129, 164]}, {"key": "in-addition-to", "type": "clause", "offset": [166, 180]}, {"key": "design-standards", "type": "definition", "offset": [209, 225]}, {"key": "not-limited", "type": "clause", "offset": [242, 253]}, {"key": "national-electrical-safety-code", "type": "definition", "offset": [273, 304]}, {"key": "design-guide", "type": "definition", "offset": [356, 368]}, {"key": "for-safety", "type": "clause", "offset": [390, 400]}, {"key": "substation-grounding", "type": "clause", "offset": [407, 427]}, {"key": "circuit-breakers", "type": "clause", "offset": [469, 485]}, {"key": "transmission-lines", "type": "clause", "offset": [564, 582]}], "samples": [{"hash": "eMKiIKRORTr", "uri": "/contracts/eMKiIKRORTr#engineering-and-design", "label": "Development Agreement", "score": 34.1044006348, "published": true}, {"hash": "be82UEHqrNG", "uri": "/contracts/be82UEHqrNG#engineering-and-design", "label": "Development Agreement", "score": 33.4039535522, "published": true}, {"hash": "fBjFR9VjQpp", "uri": "/contracts/fBjFR9VjQpp#engineering-and-design", "label": "Development Agreement", "score": 33.1753425598, "published": true}], "hash": "64e2c544bc023c5d091327b83b88eabe", "id": 7}, {"snippet": "Contractor shall engage the necessary professionals to provide engineering and design work pertaining to the Work. Contractor shall be responsible, at its sole cost (but subject to payment as provided herein), for the preparation of all subdivision improvement plans required for the Completion of the Work and for obtaining approval of such plans from all \u201cApproving Authorities\u201d (as defined in Section 3.3 below).", "size": 4, "snippet_links": [{"key": "contractor-shall", "type": "clause", "offset": [0, 16]}, {"key": "to-provide", "type": "clause", "offset": [52, 62]}, {"key": "engineering-and-design-work", "type": "definition", "offset": [63, 90]}, {"key": "pertaining-to", "type": "definition", "offset": [91, 104]}, {"key": "be-responsible", "type": "clause", "offset": [132, 146]}, {"key": "subject-to", "type": "clause", "offset": [170, 180]}, {"key": "preparation-of", "type": "clause", "offset": [218, 232]}, {"key": "plans-required", "type": "clause", "offset": [261, 275]}, {"key": "work-and", "type": "clause", "offset": [302, 310]}, {"key": "approval-of", "type": "definition", "offset": [325, 336]}, {"key": "approving-authorities", "type": "definition", "offset": [358, 379]}, {"key": "section-33", "type": "clause", "offset": [396, 407]}], "samples": [{"hash": "1ULThsLmvvJ", "uri": "/contracts/1ULThsLmvvJ#engineering-and-design", "label": "Master Construction Agreement (Millrose Properties, Inc.)", "score": 36.1019859314, "published": true}, {"hash": "e0FTfVy4wWh", "uri": "/contracts/e0FTfVy4wWh#engineering-and-design", "label": "Master Construction Agreement (Millrose Properties, Inc.)", "score": 35.9623527527, "published": true}, {"hash": "6HfJdiQ7uvI", "uri": "/contracts/6HfJdiQ7uvI#engineering-and-design", "label": "Master Construction Agreement (Millrose Properties, Inc.)", "score": 35.8227233887, "published": true}], "hash": "f0212685b460a03266830d9587f4000b", "id": 8}, {"snippet": "Contractor shall proceed with the engineering and design of the Project upon issuance of the Notice to Proceed under the Agreement. Contractor shall independently research applicable codes and engineering references to comply with City, County, State, and Federal requirements. Contractor shall provide Project design documents for review/comments/acceptance by the Owner per the requirements in the Minimum Technical Requirements (Exhibit 1). Systems should be designed so that they can preassembled/prepackaged as much as possible to make plug and play systems in an effort to reduce on site labor requirements. The use of prepackaged inverter/MV transformer skids, plug in combiner boxes are desired.", "size": 4, "snippet_links": [{"key": "design-of-the-project", "type": "clause", "offset": [50, 71]}, {"key": "the-notice-to-proceed", "type": "clause", "offset": [89, 110]}, {"key": "the-agreement", "type": "clause", "offset": [117, 130]}, {"key": "applicable-codes", "type": "clause", "offset": [172, 188]}, {"key": "references-to", "type": "definition", "offset": [205, 218]}, {"key": "comply-with", "type": "clause", "offset": [219, 230]}, {"key": "federal-requirements", "type": "definition", "offset": [256, 276]}, {"key": "documents-for-review", "type": "clause", "offset": [318, 338]}, {"key": "by-the-owner", "type": "clause", "offset": [359, 371]}, {"key": "the-requirements", "type": "clause", "offset": [376, 392]}, {"key": "minimum-technical-requirements", "type": "definition", "offset": [400, 430]}, {"key": "exhibit-1", "type": "definition", "offset": [432, 441]}, {"key": "labor-requirements", "type": "clause", "offset": [594, 612]}], "samples": [{"hash": "h31XYN5ug4m", "uri": "/contracts/h31XYN5ug4m#engineering-and-design", "label": "Engineering, Procurement and Construction Agreement (Powersecure International, Inc.)", "score": 26.0896644592, "published": true}, {"hash": "4w6bMpyLTgD", "uri": "/contracts/4w6bMpyLTgD#engineering-and-design", "label": "Engineering, Procurement and Construction Agreement (Powersecure International, Inc.)", "score": 26.0896644592, "published": true}, {"hash": "lvtn0EuwIW7", "uri": "/contracts/lvtn0EuwIW7#engineering-and-design", "label": "Engineering, Procurement and Construction Agreement (Powersecure International, Inc.)", "score": 25.8432579041, "published": true}], "hash": "67c44168b9c9897f11402da831f4b671", "id": 9}, {"snippet": "Star Service has engineers on staff and can provide our customers with Engineering and Design services from the smallest improvement to a full-service Design Build application requiring full specifications and stamped drawings. In many situations our customers have structural and mechanical issues that can be resolved in minimal time without costly delays, and job shutdowns. Our Engineering services can provide Control Design, HVAC Design, Lab Safety System, and are able to provide the latest in Green Design.", "size": 3, "snippet_links": [{"key": "engineering-and-design-services", "type": "clause", "offset": [71, 102]}, {"key": "service-design", "type": "clause", "offset": [143, 157]}, {"key": "mechanical-issues", "type": "clause", "offset": [281, 298]}, {"key": "engineering-services", "type": "clause", "offset": [382, 402]}, {"key": "safety-system", "type": "definition", "offset": [448, 461]}, {"key": "provide-the", "type": "clause", "offset": [479, 490]}], "samples": [{"hash": "9hK6sj2Ov1M", "uri": "/contracts/9hK6sj2Ov1M#engineering-and-design", "label": "Vendor Agreement", "score": 33.2031860352, "published": true}, {"hash": "5jav36h8Iiw", "uri": "/contracts/5jav36h8Iiw#engineering-and-design", "label": "Vendor Agreement", "score": 33.2031860352, "published": true}], "hash": "c720f0d085ef50c571c40abb817ab612", "id": 10}], "next_curs": "Cl8SWWoVc35sYXdpbnNpZGVyY29udHJhY3RzcjsLEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2Ih9lbmdpbmVlcmluZy1hbmQtZGVzaWduIzAwMDAwMDBhDKIBAmVuGAAgAA==", "clause": {"size": 117, "title": "Engineering and Design", "children": [["design", "Design"], ["grantors-obligations", "Grantor's Obligations"], ["grantees-obligations", "Grantee's Obligations"], ["engineering", "Engineering"], ["nus-obligations", "NU's Obligations"]], "parents": [["jurisdiction-and-venue", "Jurisdiction and Venue"], ["miscellaneous", "Miscellaneous"], ["independent-contractor", "Independent Contractor"], ["engineering-design-construction-and-construction-management", "Engineering Design Construction and Construction Management"], ["additional-responsibilities-of-contractor", "Additional Responsibilities of Contractor"]], "id": "engineering-and-design", "related": [["reverse-engineering", "Reverse Engineering", "Reverse Engineering"], ["research-and-development", "Research and Development", "Research and Development"], ["training-and-development", "Training and Development", "Training and Development"], ["engineering", "Engineering", "Engineering"], ["information-systems-acquisition-development-and-maintenance", "Information Systems Acquisition Development and Maintenance", "Information Systems Acquisition Development and Maintenance"]], "related_snippets": [], "updated": "2025-07-24T06:48:57+00:00"}, "json": true, "cursor": ""}}