Energy Conservation Measures Sample Clauses

Energy Conservation Measures a. Insulation of roofs, crawl spaces, ceilings, attics, floors and around pipes/ducts as long as these measures do not induce, retain, or introduce moisture into a building, utilization of spray foam insulation is not covered under this agreement and must be reviewed in accordance with 36 CFR Part 800. b. Caulking and weather stripping consistent with appearance of the building. c. Installation of radiant barriers in unoccupied attic spaces. d. Installation of solar panels not visible from the public right-of-way. APPENDIX B DEFINITIONS
Energy Conservation Measures. Incorporating energy conservation measures, such as enhancing insulation and transitioning to LED lighting, aims to bolster overall building efficiency. By minimizing energy waste and optimizing usage, these measures contribute to reduced energy consumption and operational costs, aligning with sustainable practices while potentially enhancing indoor comfort and lowering utility expenses.
Energy Conservation Measures. The PMSA shall report conditions that are contrary to energy/water efficiency and shall recommend energy conservation measures, discovered during Scheduled Maintenance and when processing a DMO or IJO.
Energy Conservation Measures. 3.1 Performance of the Work ESP shall perform or cause to be performed the Work in strict accordance with the Contract Documents. The Work shall also include whatever is done by or required of ESP to perform and complete its duties under the Contract Documents, including but not limited to the following: the provision or furnishing of labor, supervision, services, materials, supplies, equipment, fixtures, appliances, facilities, tools, transportation, storage, power, permits and licenses required, and fuel, heat, light, cooling and all other utilities as required by this Agreement. Notwithstanding the preceding sentence, ESP may request Owner to provide power, fuel, heat, cooling, or other utilities. Upon such request Owner may, in its sole and complete discretion, elect to provide such utilities at a price set by Owner, but Owner shall have no obligation to provide such utilities. If Owner elects to provide such utilities, ESP shall indemnify, hold harmless, and defend Owner against any damages, losses, or expenses arising from ESP’s use of Owner’s facilities or utilities at the Premises. No later than INSERT DAYS days after execution of this Agreement, ESP shall provide detailed drawings and specifications concerning the ECMs and associated equipment and materials, and all impacted areas of the Premises, for Owner’s review and comment. Such documents shall become the property of Owner without restriction. ESP shall make such reasonable modifications to the drawings and specifications as Owner may require. Upon Owner’s approval of the drawings and specifications, ESP shall proceed to provide ECM Submittals as set forth in Section 3.4. Owner’s approval of any drawings, specifications, or submittals shall not be evidence that such documents, and associated Work pursuant thereto, conform to the requirements of the Contract Documents, nor shall such approval relieve or diminish in any way ESP’s obligation to comply with the Contract Documents. 3.2 ESP’s Responsibility for the Work ESP shall perform all Work strictly in conformance with the Contract Documents. Compliance with the Contract Documents shall be and remain the responsibility of ESP. Owner or its representatives and consultants may review, inspect, and test the Work from time to time. Any review, approval, testing, or acceptance of, or payment for, any or all of the Work shall not relieve ESP of its responsibility for the Work and compliance with the Contract Documents. 3.3 Standards of the Work ESP...
Energy Conservation Measures. In progress. Carollo completed the initial investigations in 2020. The 2021 task effort includes additional coordination work with Nexant and SRP related to energy conservation and power monitoring. Carollo investigated alternative energy generation, energy reduction, and automation opportunities at each plant. As part of this effort, Carollo identified energy conservation measures (ECMs) that reduce energy use in areas like process controls, lighting, pumps, and motors.
Energy Conservation Measures. This project consists of the design and construction of energy conservation measures on the Springfield campus. The conservation measures could consist of, but are not limited to, upgrades to or replacement of components for the lighting, heating, air conditioning, temperature control, mechanical, energy management control, and domestic water. A guaranteed energy savings contract will be requested of the provider(s) so that guaranteed savings are in amount which are anticipated to be sufficient to pay the cost of that portion of the annual Installment Payments relating to this project. INDENTURE OF TRU U.S. BANK NATIONAL ASSO TION, as Trust Dated as of February 1, 2014 Draft.Indenture.doc 2212033 • AGB • 11/1/13 INDENTURE
Energy Conservation Measures. During the Contract Documents Phase consisting of preparation of final mechanical engineering calculations, Drawings and Specifications based on approved Design Development Documents, setting forth in detail the mechanical construction requirements for the Project.
Energy Conservation Measures. The Project shall include the following energy conservation measures which are currently requirements of the SMMC. Nothing in this Section 2.7.14 shall preclude the City from applying Subsequent Code Changes permitted in accordance with Section 5.2. (a) Consistent with EIR Section 4.9.3.4, the Project shall be designed to be five percent (5%) more efficient than the code established by the 2019 California Energy Code. (b) Developer shall install a photovoltaic (PV) system that has a minimum total wattage of 2.0 times the square footage of the building’s footprint (2.0 ▇▇▇▇▇ per square foot of building footprint) in accordance with SMMC 8.160.080; (c) For new pool construction in the Project, if the pool is to be heated, an electric heat pump water heater or a solar thermal system shall be used for such heating in accordance with SMMC 8.106.080, or successor thereto; and (d) The Project shall include the following electric vehicle charging infrastructure in the parking areas of the Subterranean Space in accordance with SMMC 4.106.4: (i) EV chargers in forty-three (43) parking spaces, (ii) Infrastructure to make an additional twenty six (26) parking spaces EV Ready (breaker, wiring, panel capacity, receptacle and raceways and associated conductors capable of accommodating 208/240-volt dedicated branch circuits), and (iii) Raceways/conduits and associated conductors capable of accommodating 208/240-volt dedicated branch circuits in an additional one hundred eighty-two (182) parking spaces.
Energy Conservation Measures. This project consists of the design and construction of energy conservation measures on the Carbondale campus. The conservation measures would consist of a combination of high efficiency lighting and plumbing upgrades, high efficiency HVAC components, energy management system upgrades, as well as miscellaneous items such as high efficiency motors and occupancy sensors.