{"component": "clause", "props": {"groups": [{"samples": [{"hash": "cw4idEca9Nx", "uri": "/contracts/cw4idEca9Nx#developer-operating-requirements", "label": "Interconnection Agreement", "score": 27.707567215, "published": true}, {"hash": "bXipooa5KYT", "uri": "/contracts/bXipooa5KYT#developer-operating-requirements", "label": "Interconnection Agreement", "score": 25.5051326752, "published": true}, {"hash": "6VC4IRthegg", "uri": "/contracts/6VC4IRthegg#developer-operating-requirements", "label": "Interconnection Agreement", "score": 25.4668045044, "published": true}], "snippet_links": [{"key": "the-developer-must", "type": "clause", "offset": [0, 18]}, {"key": "the-transmission", "type": "clause", "offset": [31, 47]}, {"key": "operating-instructions", "type": "definition", "offset": [56, 78]}, {"key": "not-limited", "type": "clause", "offset": [110, 121]}, {"key": "coordination-agreement", "type": "clause", "offset": [156, 178]}, {"key": "from-time-to-time", "type": "clause", "offset": [197, 214]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [262, 275]}, {"key": "and-procedures", "type": "clause", "offset": [276, 290]}, {"key": "as-amended", "type": "definition", "offset": [292, 302]}, {"key": "large-generating-facility", "type": "clause", "offset": [341, 366]}, {"key": "transition-period-lvrt-standard", "type": "clause", "offset": [387, 418]}, {"key": "appendix-g", "type": "clause", "offset": [432, 442]}, {"key": "by-the-commission", "type": "clause", "offset": [462, 479]}, {"key": "facility-will", "type": "clause", "offset": [502, 515]}, {"key": "an-order", "type": "definition", "offset": [584, 592]}, {"key": "for-purposes-of", "type": "clause", "offset": [654, 669]}, {"key": "with-appendix", "type": "clause", "offset": [681, 694]}, {"key": "developer-shall", "type": "clause", "offset": [745, 760]}, {"key": "equipment-and-operations", "type": "clause", "offset": [914, 938]}, {"key": "hardware-and-software", "type": "definition", "offset": [951, 972]}, {"key": "to-ensure", "type": "clause", "offset": [986, 995]}, {"key": "system-reliability", "type": "definition", "offset": [1035, 1053]}, {"key": "operational-security", "type": "clause", "offset": [1058, 1078]}, {"key": "the-commission-will", "type": "clause", "offset": [1080, 1099]}, {"key": "transmission-owners", "type": "definition", "offset": [1122, 1141]}, {"key": "market-participants", "type": "definition", "offset": [1172, 1191]}, {"key": "offered-by", "type": "definition", "offset": [1227, 1237]}, {"key": "the-president", "type": "clause", "offset": [1238, 1251]}, {"key": "protection-board", "type": "definition", "offset": [1278, 1294]}, {"key": "best-practice", "type": "clause", "offset": [1312, 1325]}, {"key": "reliability-authority", "type": "definition", "offset": [1360, 1381]}, {"key": "public-utilities", "type": "definition", "offset": [1387, 1403]}, {"key": "basic-standards", "type": "definition", "offset": [1429, 1444]}, {"key": "system-infrastructure", "type": "definition", "offset": [1449, 1470]}, {"key": "security-practices", "type": "definition", "offset": [1540, 1558]}, {"key": "all-personnel", "type": "clause", "offset": [1560, 1573]}, {"key": "security-background-checks", "type": "clause", "offset": [1630, 1656]}, {"key": "prior-to", "type": "clause", "offset": [1657, 1665]}, {"key": "new-york-independent-system-operator", "type": "definition", "offset": [1707, 1743]}, {"key": "senior-vice-president", "type": "definition", "offset": [1822, 1843]}, {"key": "new-york-power-authority", "type": "clause", "offset": [1860, 1884]}, {"key": "operation-of", "type": "clause", "offset": [2005, 2017]}, {"key": "unit-no", "type": "definition", "offset": [2018, 2025]}, {"key": "commenced-commercial-operation", "type": "definition", "offset": [2067, 2097]}, {"key": "thank-you", "type": "definition", "offset": [2181, 2190]}], "snippet": "The Developer must comply with the Transmission Owner\u2019s operating instructions and requirements including but not limited to Transmission Owner\u2019s Operation Coordination Agreement, as it may change from time to time. The Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time. Whether or not the Large Generating Facility is eligible for the Transition Period LVRT Standard set forth in Appendix G will be determined by the Commission. The Large Generating Facility will comply with the Transition Period LVRT Standard pending issuance of an order by the Commission determining the appropriate LVRT standard. For purposes of compliance with Appendix G, the Transmission Owner has determined that the Developer shall maintain the Large Generating Facility in service during a three-phase fault for 7 cycles. Infrastructure security of New York State Transmission System equipment and operations and control hardware and software is essential to ensure day-to-day New York State Transmission System reliability and operational security. The Commission will expect the NYISO, all Transmission Owners, all Developers and all other Market Participants to comply with the recommendations offered by the President\u2019s Critical Infrastructure Protection Board and, eventually, best practice recommendations from the electric reliability authority. All public utilities will be expected to meet basic standards for system infrastructure and operational security, including physical, operational, and cyber-security practices. All personnel working in Transmission Owner\u2019s facilities will require security background checks prior to entering and working in such facilities. New York Independent System Operator, Inc. Attn: Vice President, Operations \u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587 Schenectady, NY 12303 Senior Vice President of Transmission New York Power Authority \u2587\u2587\u2587 \u2587\u2587\u2587\u2587 \u2587\u2587. \u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587\u2587, \u2587\u2587 \u2587\u2587\u2587\u2587\u2587-\u2587\u2587\u2587\u2587 Re: Large Generating Facility Dear : On [Date] [Developer] has completed Trial Operation of Unit No. . This letter confirms that [Developer] commenced Commercial Operation of Unit No. at the Large Generating Facility, effective as of [Date plus one day]. Thank you. NYISO:", "size": 45, "hash": "8738162d8b58c2ac9d4fd104cce1de69", "id": 1}, {"samples": [{"hash": "bK9dS88NwXS", "uri": "/contracts/bK9dS88NwXS#developer-operating-requirements", "label": "Interconnection Agreement", "score": 33.3305358887, "published": true}, {"hash": "1Sd1ba9TqyX", "uri": "/contracts/1Sd1ba9TqyX#developer-operating-requirements", "label": "Interconnection Agreement", "score": 31.7561321259, "published": true}, {"hash": "kNca4TIsYiF", "uri": "/contracts/kNca4TIsYiF#developer-operating-requirements", "label": "Interconnection Agreement", "score": 27.707567215, "published": true}], "snippet_links": [{"key": "the-connecting-transmission-owner", "type": "definition", "offset": [27, 60]}, {"key": "operating-instructions", "type": "definition", "offset": [63, 85]}, {"key": "provisions-of-this-agreement", "type": "clause", "offset": [146, 174]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [194, 207]}, {"key": "and-procedures", "type": "clause", "offset": [208, 222]}, {"key": "as-amended", "type": "definition", "offset": [224, 234]}, {"key": "from-time-to-time", "type": "clause", "offset": [235, 252]}], "snippet": "Developer must comply with the Connecting Transmission Owner\u2019s operating instructions and requirements. Developer must comply will all applicable provisions of this Agreement and all applicable NYISO tariffs and procedures, as amended from time to time.", "size": 38, "hash": "4bb5cae82b052bf0990c1082c5ef2991", "id": 2}, {"samples": [{"hash": "14AUpmfwtem", "uri": "/contracts/14AUpmfwtem#developer-operating-requirements", "label": "Standard Large Generator Interconnection Agreement", "score": 31.2431507111, "published": true}, {"hash": "5lnT10MReWZ", "uri": "/contracts/5lnT10MReWZ#developer-operating-requirements", "label": "Standard Large Generator Interconnection Agreement", "score": 27.6022758484, "published": true}, {"hash": "4jX4x8wcV8G", "uri": "/contracts/4jX4x8wcV8G#developer-operating-requirements", "label": "Standard Large Generator Interconnection Agreement", "score": 26.2211761475, "published": true}], "snippet_links": [{"key": "comply-with", "type": "clause", "offset": [15, 26]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [42, 55]}, {"key": "and-procedures", "type": "clause", "offset": [56, 70]}, {"key": "as-amended", "type": "definition", "offset": [72, 82]}, {"key": "from-time-to-time", "type": "clause", "offset": [83, 100]}, {"key": "large-generating-facility", "type": "clause", "offset": [106, 131]}, {"key": "a-member-of", "type": "clause", "offset": [135, 146]}, {"key": "class-year", "type": "clause", "offset": [147, 157]}, {"key": "not-completed", "type": "clause", "offset": [173, 186]}, {"key": "effective-date-of-this", "type": "clause", "offset": [197, 219]}, {"key": "amended-and-restated", "type": "definition", "offset": [220, 240]}, {"key": "interconnection-agreement", "type": "clause", "offset": [241, 266]}, {"key": "attachment-facilities", "type": "clause", "offset": [275, 296]}, {"key": "system-upgrade-facilities", "type": "definition", "offset": [298, 323]}, {"key": "other-upgrades", "type": "clause", "offset": [328, 342]}, {"key": "in-the-class", "type": "clause", "offset": [388, 400]}, {"key": "interconnection-facilities-study", "type": "definition", "offset": [411, 443]}, {"key": "the-facilities", "type": "clause", "offset": [476, 490]}, {"key": "the-parties-shall", "type": "clause", "offset": [539, 556]}, {"key": "developer-shall", "type": "clause", "offset": [760, 775]}, {"key": "the-cost", "type": "clause", "offset": [783, 791]}, {"key": "allocated-to", "type": "definition", "offset": [792, 804]}, {"key": "security-and", "type": "clause", "offset": [929, 941]}, {"key": "payment-required", "type": "clause", "offset": [951, 967]}, {"key": "nyiso-oatt", "type": "definition", "offset": [1001, 1011]}, {"key": "commercial-operation", "type": "definition", "offset": [1066, 1086]}, {"key": "settlement-of-the", "type": "clause", "offset": [1106, 1123]}, {"key": "pursuant-to-this-agreement", "type": "clause", "offset": [1178, 1204]}, {"key": "agrees-to", "type": "clause", "offset": [1215, 1224]}, {"key": "cost-allocation", "type": "definition", "offset": [1236, 1251]}, {"key": "required-security", "type": "definition", "offset": [1323, 1340]}, {"key": "payment-upon", "type": "clause", "offset": [1362, 1374]}, {"key": "unforced-capacity", "type": "clause", "offset": [1441, 1458]}, {"key": "acceptance-of", "type": "definition", "offset": [1629, 1642]}], "snippet": "Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time. The Large Generating Facility is a member of Class Year 2010, which is not completed as of the effective date of this Amended and Restated Interconnection Agreement. If the Attachment Facilities, System Upgrade Facilities, or other upgrades for the Large Generating Facility identified in the Class Year 2010 Interconnection Facilities Study differ in any material way from the facilities identified in the Appendices to this Agreement, the Parties shall amend this Agreement, pursuant to its sections 29.11 and 29.12, to reflect the Attachment Facilities, System Upgrade Facilities, or other upgrades identified in the Class Year 2010 Facilities Study. The Developer shall accept the cost allocated to the Large Generating Facility for SUFs through the Class Year 2010 Interconnection Facilities Study and post any associated security and make any payment required, pursuant to Attachment S of the NYISO OATT. The Large Generating Facility may commence Trial and Commercial Operation prior to the final settlement of the Class Year 2010 Interconnection Facilities Study; and pursuant to this Agreement Developer agrees to accept its cost allocation from the Class Year 2010 Interconnection Facilities Study and post any required security or make any required payment upon final settlement of Class Year 2010. The Developer may not supply Unforced Capacity to the NYCA from the Large Generating Facility until the Developer has complied with the deliverability requirement pursuant to Attachment S of the NYISO OATT, including acceptance of any cost allocated to the Large Generating Facility for SDUs through the Class Year 2010 Interconnection Facilities Study and the posting of associated security or payments.", "size": 20, "hash": "fbc66a0683b50dd75d2ac0ed6cecbb39", "id": 3}, {"samples": [{"hash": "8MTejv9mCda", "uri": "/contracts/8MTejv9mCda#developer-operating-requirements", "label": "Interconnection Agreement", "score": 25.707567215, "published": true}, {"hash": "g12A4vvHRDk", "uri": "/contracts/g12A4vvHRDk#developer-operating-requirements", "label": "Interconnection Agreement", "score": 24.2211761475, "published": true}, {"hash": "ez88psNClQi", "uri": "/contracts/ez88psNClQi#developer-operating-requirements", "label": "Interconnection Agreement", "score": 24.2211761475, "published": true}], "snippet_links": [{"key": "developer-shall", "type": "clause", "offset": [4, 19]}, {"key": "comply-with", "type": "clause", "offset": [20, 31]}, {"key": "provisions-of", "type": "clause", "offset": [36, 49]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [50, 63]}, {"key": "and-procedures", "type": "clause", "offset": [64, 78]}, {"key": "as-amended", "type": "definition", "offset": [80, 90]}, {"key": "from-time-to-time", "type": "clause", "offset": [91, 108]}, {"key": "the-merchant", "type": "clause", "offset": [139, 151]}, {"key": "transmission-facility", "type": "definition", "offset": [152, 173]}, {"key": "tariff-revisions", "type": "clause", "offset": [240, 256]}, {"key": "operating-protocols", "type": "definition", "offset": [264, 283]}, {"key": "the-connecting-transmission-owner", "type": "definition", "offset": [301, 334]}, {"key": "the-facility", "type": "clause", "offset": [502, 514]}, {"key": "operating-instructions", "type": "definition", "offset": [578, 600]}, {"key": "data-circuits", "type": "clause", "offset": [666, 679]}, {"key": "by-developer", "type": "clause", "offset": [697, 709]}, {"key": "in-accordance-with", "type": "clause", "offset": [710, 728]}, {"key": "this-agreement", "type": "clause", "offset": [744, 758]}, {"key": "by-telephone", "type": "clause", "offset": [804, 816]}, {"key": "other-means-of-communication", "type": "clause", "offset": [826, 854]}, {"key": "the-parties", "type": "definition", "offset": [858, 869]}], "snippet": "(a) Developer shall comply with all provisions of NYISO tariffs and procedures, as amended from time to time, which apply to any aspect of the Merchant Transmission Facility\u2019s operations and its participation in NYISO-administered markets. Tariff revisions and/or operating protocols with NYISO, PJM, the Connecting Transmission Owner, and Developer may need to be developed to incorporate the Merchant Transmission Facility into NYISO-administered markets and to coordinate the operational control of the facility.\n(b) Developer shall comply with Connecting Transmission Owner operating instructions and requirements, which requirements shall include the dedicated data circuits to be maintained by Developer in accordance with Article 8.1 of this Agreement. Operating instructions will be communicated by telephone, or such other means of communication as the Parties may agree upon.", "size": 11, "hash": "090e963981bc341bea2fd01ab5951033", "id": 4}, {"samples": [{"hash": "lG4bHnShBCY", "uri": "/contracts/lG4bHnShBCY#developer-operating-requirements", "label": "Interconnection Agreement", "score": 32.5467338562, "published": true}, {"hash": "hPzAot8RiWn", "uri": "/contracts/hPzAot8RiWn#developer-operating-requirements", "label": "Standard Large Generator Interconnection Agreement", "score": 32.4694824219, "published": true}, {"hash": "agi8fJrSFrb", "uri": "/contracts/agi8fJrSFrb#developer-operating-requirements", "label": "Interconnection Agreement", "score": 32.1229057312, "published": true}], "snippet_links": [{"key": "nyiso-tariffs", "type": "definition", "offset": [46, 59]}, {"key": "and-procedures", "type": "clause", "offset": [60, 74]}, {"key": "as-amended", "type": "definition", "offset": [76, 86]}, {"key": "from-time-to-time", "type": "clause", "offset": [87, 104]}, {"key": "the-connecting-transmission-owner", "type": "definition", "offset": [137, 170]}, {"key": "operating-instructions", "type": "definition", "offset": [173, 195]}, {"key": "to-the-extent", "type": "clause", "offset": [244, 257]}, {"key": "agreement-or", "type": "definition", "offset": [298, 310]}, {"key": "nyiso-oatt", "type": "definition", "offset": [315, 325]}], "snippet": "(a) Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time.\n(b) Developer must comply with the Connecting Transmission Owner\u2019s operating instructions and requirements, as amended from time to time, to the extent not inconsistent with the terms of this Agreement or the NYISO OATT.", "size": 10, "hash": "8ac811163c416b69be7de2de47143812", "id": 5}, {"samples": [{"hash": "5ok2davSKoJ", "uri": "/contracts/5ok2davSKoJ#developer-operating-requirements", "label": "Interconnection Agreement", "score": 30.9705085754, "published": true}, {"hash": "5npRWEnvdUr", "uri": "/contracts/5npRWEnvdUr#developer-operating-requirements", "label": "Standard Large Generator Interconnection Agreement", "score": 26.1121883392, "published": true}, {"hash": "bpMwdhr994v", "uri": "/contracts/bpMwdhr994v#developer-operating-requirements", "label": "Interconnection Agreement", "score": 24.2306632996, "published": true}], "snippet_links": [{"key": "comply-with", "type": "clause", "offset": [15, 26]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [42, 55]}, {"key": "and-procedures", "type": "clause", "offset": [56, 70]}, {"key": "as-amended", "type": "definition", "offset": [72, 82]}, {"key": "from-time-to-time", "type": "clause", "offset": [83, 100]}], "snippet": "Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time.", "size": 8, "hash": "4a9e16e36459f1b58b0d2254ba98ff3f", "id": 6}, {"samples": [{"hash": "Mks9o3l4YR", "uri": "/contracts/Mks9o3l4YR#developer-operating-requirements", "label": "Interconnection Agreement", "score": 25.1984939575, "published": true}, {"hash": "dXzIa1zYo9r", "uri": "/contracts/dXzIa1zYo9r#developer-operating-requirements", "label": "Interconnection Agreement", "score": 23.2737846375, "published": true}], "snippet_links": [{"key": "comply-with", "type": "clause", "offset": [15, 26]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [42, 55]}, {"key": "and-procedures", "type": "clause", "offset": [56, 70]}, {"key": "as-amended", "type": "definition", "offset": [72, 82]}, {"key": "from-time-to-time", "type": "clause", "offset": [83, 100]}, {"key": "connecting-transmission-owner", "type": "definition", "offset": [129, 158]}, {"key": "operating-instructions", "type": "definition", "offset": [161, 183]}, {"key": "operating-requirements", "type": "clause", "offset": [258, 280]}, {"key": "con-edison", "type": "definition", "offset": [289, 299]}, {"key": "generation-plant", "type": "definition", "offset": [347, 363]}, {"key": "electrical-system", "type": "definition", "offset": [406, 423]}, {"key": "line-diagram", "type": "clause", "offset": [528, 540]}, {"key": "jurisdictional-boundaries", "type": "clause", "offset": [564, 589]}, {"key": "system-operator", "type": "clause", "offset": [706, 721]}, {"key": "in-accordance-with", "type": "clause", "offset": [829, 847]}, {"key": "department-procedures", "type": "clause", "offset": [867, 888]}, {"key": "general-instructions", "type": "definition", "offset": [934, 954]}, {"key": "work-on", "type": "clause", "offset": [965, 972]}, {"key": "electrical-equipment", "type": "clause", "offset": [980, 1000]}, {"key": "in-total", "type": "clause", "offset": [1130, 1138]}, {"key": "the-ecc", "type": "clause", "offset": [1144, 1151]}, {"key": "control-room-operator", "type": "clause", "offset": [1160, 1181]}, {"key": "not-available", "type": "clause", "offset": [1209, 1222]}, {"key": "for-any-reason", "type": "clause", "offset": [1223, 1237]}, {"key": "telephone-line", "type": "definition", "offset": [1292, 1306]}, {"key": "the-plant", "type": "clause", "offset": [1371, 1380]}, {"key": "the-district", "type": "clause", "offset": [1419, 1431]}, {"key": "change-in", "type": "clause", "offset": [1448, 1457]}, {"key": "telephone-number", "type": "definition", "offset": [1485, 1501]}, {"key": "procedures-and-policies", "type": "clause", "offset": [1533, 1556]}, {"key": "relationship-between", "type": "clause", "offset": [1578, 1598]}, {"key": "not-limited", "type": "clause", "offset": [1644, 1655]}, {"key": "in-order-to", "type": "clause", "offset": [1717, 1728]}, {"key": "designed-capacity", "type": "definition", "offset": [1752, 1769]}, {"key": "substation-equipment", "type": "clause", "offset": [1786, 1806]}, {"key": "in-the-case", "type": "clause", "offset": [1807, 1818]}, {"key": "mw-output", "type": "definition", "offset": [1911, 1920]}, {"key": "upon-notification", "type": "clause", "offset": [1921, 1938]}, {"key": "notification-to", "type": "clause", "offset": [2066, 2081]}, {"key": "in-the-event", "type": "clause", "offset": [2121, 2133]}, {"key": "respond-to", "type": "definition", "offset": [2228, 2238]}, {"key": "as-directed", "type": "clause", "offset": [2251, 2262]}, {"key": "the-generator", "type": "clause", "offset": [2402, 2415]}, {"key": "step-up", "type": "clause", "offset": [2459, 2466]}, {"key": "no-load", "type": "definition", "offset": [2481, 2488]}, {"key": "list-of-personnel", "type": "definition", "offset": [2578, 2595]}, {"key": "authorized-by", "type": "definition", "offset": [2596, 2609]}, {"key": "requested-by", "type": "clause", "offset": [2765, 2777]}, {"key": "system-operations", "type": "definition", "offset": [2789, 2806]}, {"key": "a-qualified", "type": "clause", "offset": [2887, 2898]}, {"key": "available-at", "type": "definition", "offset": [2936, 2948]}, {"key": "plant-operator", "type": "definition", "offset": [3098, 3112]}, {"key": "operating-order", "type": "definition", "offset": [3133, 3148]}, {"key": "qualified-operators", "type": "definition", "offset": [3162, 3181]}, {"key": "section-5", "type": "clause", "offset": [3224, 3233]}, {"key": "changes-in", "type": "definition", "offset": [3257, 3267]}, {"key": "status-of-equipment", "type": "clause", "offset": [3282, 3301]}, {"key": "authority-of-the", "type": "clause", "offset": [3374, 3390]}, {"key": "in-section-2", "type": "clause", "offset": [3429, 3441]}], "snippet": "Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time. Developer must comply with Connecting Transmission Owner\u2019s operating instructions and requirements which are set forth below. \u2022 This document describes the operating requirements between Con Edison\u2019s System Operation Department and \u2587\u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587 Generation Plant (the \u201cPlant\u201d) connected to the Con Edison electrical system at Goethals 345KV Substation as illustrated on Goethals 60 cycles operating diagram 70. \u2022 Operating one-line diagram 9C shows the operating jurisdictional boundaries of Con Edison\u2019s System Operation Department. \u2022 The Con Edison District Operator (\u201cDistrict Operator\u201d) or Con Edison System Operator (\u201cSystem Operator\u201d) shall direct all operations on equipment within Con Edison\u2019s jurisdictional boundaries in accordance with System Operation\u2019s Department Procedures/Con Edison specifications and the Con Edison General Instructions Governing Work on System Electrical Equipment (the \u201cRulebook\u201d). \u2022 Con Edison\u2019s District Operator and System Operator each shall have a dedicated direct line (two direct lines in total from the ECC) to the Control Room Operator and if such direct line is not available for any reason, the Control Room Operator can be reached via outside telephone line at \u2587\u2587\u2587-\u2587\u2587\u2587-\u2587\u2587\u2587\u2587 or \u2587\u2587\u2587-\u2587\u2587\u2587-\u2587\u2587\u2587\u2587 or such other telephone line as the Plant shall provide. The Plant shall notify the District Operator of any change in their control room outside telephone number. \u2022 Additional System Operation procedures and policies govern the operating relationship between Con Edison and \u2587\u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587 includes, but is not limited to Rulebook, and System Operation Department\u2019s Procedures. \u2022 In order to not exceed the nominal designed capacity of the Goethals Substation equipment in the case of a trip out of Con Edison feeders exiting Goethals Substation, the Plant shall reduce its MW output upon notification from the Con Edison District Operator or Con Edison System Operator. \u2022 \u2587\u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587 will operate the Plant and provide advance notification to the Con Edison Chief District Operator in the event that the Plant changes ownership or will be operated by a different entity. \u2022 The Plant shall respond to emergencies as directed by the Con Edison System Operator, and/or Con Edison District Operator. \u2022 The Plant shall provide to the Con Edison Chief System Operator, the generator\u2019s MVAR capability curves and the Generator Step Up transformer\u2019s No Load Tap Changer ranges and settings after each update. \u2022 The Plant shall maintain an updated list of personnel authorized by \u2587\u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587 to perform switching within the Plant. Updated lists shall be transmitted to the Con Edison Chief District Operator after each update, and as requested by Con Edison System Operations, and will be utilized when issuing operating orders The Plant shall ensure that a qualified control room operator will always be available at the Plant control room. \u2022 The Con Edison District Operator, when directed by the Con Edison System Operator, shall issue all orders to an authorized Plant Operator who will prepare an operating order and dispatch qualified operators to carry out the order in accordance with Section 5 of the Rulebook. \u2022 All changes in the operating status of equipment within the Con Edison jurisdictional boundaries shall be under the sole authority of the Con Edison System Operator, as stated in Section 2 of the Rulebook and in System Operation\u2019s Department", "size": 8, "hash": "c3617ef86db1f1bc393e1d91549ae387", "id": 7}, {"samples": [{"hash": "kFQpETtFVcB", "uri": "/contracts/kFQpETtFVcB#developer-operating-requirements", "label": "Service Agreement", "score": 25.3436012268, "published": true}, {"hash": "i46LGqx4EfC", "uri": "/contracts/i46LGqx4EfC#developer-operating-requirements", "label": "Interconnection Agreement", "score": 25.1478443146, "published": true}, {"hash": "g11QFogrQye", "uri": "/contracts/g11QFogrQye#developer-operating-requirements", "label": "Transmission Facility Interconnection Agreement", "score": 24.4145126343, "published": true}], "snippet_links": [{"key": "developer-shall", "type": "clause", "offset": [4, 19]}, {"key": "provisions-of", "type": "clause", "offset": [36, 49]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [50, 63]}, {"key": "and-procedures", "type": "clause", "offset": [64, 78]}, {"key": "as-amended", "type": "definition", "offset": [80, 90]}, {"key": "from-time-to-time", "type": "clause", "offset": [91, 108]}, {"key": "transmission-project", "type": "definition", "offset": [143, 163]}, {"key": "tariff-revisions", "type": "clause", "offset": [178, 194]}, {"key": "operating-protocols", "type": "definition", "offset": [202, 221]}, {"key": "the-connecting-transmission-owner", "type": "definition", "offset": [234, 267]}, {"key": "the-facility", "type": "clause", "offset": [349, 361]}, {"key": "each-party", "type": "clause", "offset": [367, 377]}, {"key": "comply-with-the", "type": "clause", "offset": [384, 399]}, {"key": "other-party", "type": "clause", "offset": [400, 411]}, {"key": "operating-instructions", "type": "definition", "offset": [414, 436]}, {"key": "data-circuits", "type": "clause", "offset": [502, 515]}, {"key": "by-developer", "type": "clause", "offset": [533, 545]}, {"key": "in-accordance-with", "type": "clause", "offset": [546, 564]}, {"key": "this-agreement", "type": "clause", "offset": [580, 594]}, {"key": "by-telephone", "type": "clause", "offset": [640, 652]}, {"key": "other-means-of-communication", "type": "clause", "offset": [662, 690]}, {"key": "the-parties", "type": "definition", "offset": [694, 705]}], "snippet": "(a) Developer shall comply with all provisions of NYISO tariffs and procedures, as amended from time to time, which apply to any aspect of the Transmission Project\u2019s operations. Tariff revisions and/or operating protocols with NYISO, the Connecting Transmission Owner, and Developer may need to be developed to coordinate the operational control of the facility.\n(b) Each Party shall comply with the other Party\u2019s operating instructions and requirements, which requirements shall include the dedicated data circuits to be maintained by Developer in accordance with Article 8.1 of this Agreement. Operating instructions will be communicated by telephone, or such other means of communication as the Parties may agree upon.", "size": 7, "hash": "df5ed5cd13d8275207fca1a113baedc8", "id": 8}, {"samples": [{"hash": "46xvkX1YVmg", "uri": "/contracts/46xvkX1YVmg#developer-operating-requirements", "label": "Interconnection Agreement", "score": 26.2239131927, "published": true}, {"hash": "3Fhud5zL6NP", "uri": "/contracts/3Fhud5zL6NP#developer-operating-requirements", "label": "Interconnection Agreement", "score": 26.2211761475, "published": true}, {"hash": "1aAISiwYEUy", "uri": "/contracts/1aAISiwYEUy#developer-operating-requirements", "label": "Interconnection Agreement", "score": 24.5468864441, "published": true}], "snippet_links": [{"key": "nyiso-requirements", "type": "clause", "offset": [4, 22]}], "snippet": "(a) NYISO Requirements", "size": 6, "hash": "f581517ca80a570e719c1587698e0dd3", "id": 9}, {"samples": [{"hash": "2lZnkvIbvRX", "uri": "/contracts/2lZnkvIbvRX#developer-operating-requirements", "label": "Interconnection Agreement", "score": 33.5390205383, "published": true}, {"hash": "43r10zHhtsf", "uri": "/contracts/43r10zHhtsf#developer-operating-requirements", "label": "Interconnection Agreement", "score": 26.2211761475, "published": true}, {"hash": "5TtHNAcmeD0", "uri": "/contracts/5TtHNAcmeD0#developer-operating-requirements", "label": "Interconnection Agreement", "score": 26.1773681641, "published": true}], "snippet_links": [{"key": "comply-with", "type": "clause", "offset": [19, 30]}, {"key": "nyiso-tariffs", "type": "definition", "offset": [46, 59]}, {"key": "and-procedures", "type": "clause", "offset": [60, 74]}, {"key": "as-amended", "type": "definition", "offset": [76, 86]}, {"key": "from-time-to-time", "type": "clause", "offset": [87, 104]}, {"key": "national-grid", "type": "clause", "offset": [137, 150]}, {"key": "operating-instructions", "type": "definition", "offset": [153, 175]}, {"key": "data-circuits", "type": "clause", "offset": [288, 301]}, {"key": "system-protection", "type": "clause", "offset": [313, 330]}, {"key": "by-developer", "type": "clause", "offset": [358, 370]}, {"key": "in-accordance-with", "type": "clause", "offset": [371, 389]}, {"key": "service-agreement-no", "type": "clause", "offset": [425, 445]}, {"key": "provisions-of", "type": "clause", "offset": [492, 505]}, {"key": "electric-system", "type": "clause", "offset": [522, 537]}, {"key": "to-the-extent", "type": "clause", "offset": [604, 617]}, {"key": "agreement-or", "type": "definition", "offset": [658, 670]}, {"key": "nyiso-oatt", "type": "definition", "offset": [675, 685]}], "snippet": "(a) Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time.\n(b) Developer must comply with National Grid\u2019s operating instructions and requirements as referenced in Article 9.3 of this Agreement, which requirements shall include the dedicated data circuits, including system protection circuits, to be maintained by Developer in accordance with Article 8.1 of this Agreement. C-2 SERVICE AGREEMENT NO. 1757\n(c) Developer must comply with relevant provisions of National Grid\u2019s Electric System Bulletin 756, including appendices, as amended from time to time, to the extent not inconsistent with the terms of this Agreement or the NYISO OATT.", "size": 5, "hash": "9de56d472112ffdeecc7aac40dbe170e", "id": 10}], "next_curs": "CmkSY2oVc35sYXdpbnNpZGVyY29udHJhY3RzckULEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2IilkZXZlbG9wZXItb3BlcmF0aW5nLXJlcXVpcmVtZW50cyMwMDAwMDAwYQyiAQJlbhgAIAA=", "clause": {"parents": [["other-transmission-rights", "Other Transmission Rights"], ["miscellaneous", "Miscellaneous"], ["milestones", "Milestones"], ["other-requirements", "Other Requirements"], ["attachment", "ATTACHMENT"]], "children": [["station-power", "Station Power"], ["", ""], ["technical-standards-applicable-to-a-wind-generating-plant", "Technical Standards Applicable to a Wind Generating Plant"], ["additional-agreements", "Additional Agreements"], ["voltage-schedules", "Voltage Schedules"]], "size": 221, "title": "Developer Operating Requirements", "id": "developer-operating-requirements", "related": [["operating-requirements", "Operating Requirements", "Operating Requirements"], ["forecasting-requirements", "Forecasting Requirements", "Forecasting Requirements"], ["staffing-requirements", "Staffing Requirements", "Staffing Requirements"], ["training-requirements", "Training Requirements", "Training Requirements"], ["testing-requirements", "Testing Requirements", "Testing Requirements"]], "related_snippets": [], "updated": "2025-07-24T04:27:57+00:00"}, "json": true, "cursor": ""}}