Demising Partitions Sample Clauses

Demising Partitions. All demising partitions between Tenant's space and adjacent space must be fully sheathed using 5/8" Type X gypsum board, taped and finished, from floor to structure above.
AutoNDA by SimpleDocs
Demising Partitions. Shall be constructed to extend from floor slab to underside of roof deck or steel beam above. Construct with fire rated code 5/8" type X gypsum wallboard on each side, sound batt insulation in 3 5/8" metal studs (24" on center) taped and spackled with vinyl base. Fire rated caulk to be applied all around. Each side of the partition to be painted with two (2) coats of flat paint and contains a 4" carpet base. Any other unfinished concrete or masonry walls or columns are to be furred with _____ gypsum wallboard over 1 1/2" studs at 24" on center. Insulation is to be provided per the design energy calculations.
Demising Partitions. Demising partitions are not load bearing and Tenant may not hang fixtures from them. Should Tenant require structure and/or backing to accommodate the loading of Tenant's wall hung fixtures, said request shall be in writing to Landlord for approval. Additional structure and backing shall be furnished and installed by Tenant at Tenant's expense. Tenant shall install drywall, taped, floated, sanded and painted on demising partitions between Tenant spaces up to at least 12' - 0" above concrete. Drywall may be placed on demising partition above 12'-0" without Landlord's specific approval. A demising cap, supplied by the Landlord will be installed on the storefront glass at the location of the demising partition or at any location along the storefront that the landlord deems necessary.
Demising Partitions. Landlord shall install metal wall studs, 16" on center, between all leased premises. Where rated walls are required between Leased Premises and service/exit corridors Landlord shall install 5/8" fire code gypsum board from the floor to the roof deck on both Landlord and Tenant sides, along demising partitions separating Tenant from service/exit corridors.
Demising Partitions. Demising partitions are not load bearing and Tenant may not hang fixtures from them. Should Tenant require structure and/or backing to accommodate the loading of Tenant's wall hung fixtures, said request shall be in writing to landlord for approval. Additional structure and backing shall be furnished and installed by Tenant at Tenant's Expense. Tenant shall install drywall, taped and spackled on demising partitions between tenants. No drywall shall be placed on demising partitions above 12'-0" without Landlord's specific approval. Above 12'-0" the Tenant may, subject to Landlord's prior written approval, continue with wire mesh for security purposes if so indicated on Tenant's construction drawings. The Tenant, upon Landlord's approval, may also install drywall to a higher level if openings of sufficient size are provided to assure that the smoke venting system provided by the Landlord functions as designed - see Tenant Handbook for specific requirements.
Demising Partitions. Furnish and install partitions with 2½" x 25 gauge metal studs at 24" on center, slab to slab, at floors above the ground floor, with one layer of 5/8" thick type "X" drywall on each side. Provide 2½" thick full batt sound insulation, seismic bracing as required, and control joints and control joint sealants in partitions, as recommended by gypsum wall board manufacturer. All joints are to be taped; visible joints to be spackled and sanded ready for painting. Caulk joint between bottom of wall board and the floor. (Minimum Standard: One half (½) of the cost of demising partitions shall be allocated between adjacent tenants.)
Demising Partitions. A. PARTY WALL PARTITIONS separating Tenant spaces shall be constructed of 3 1/2" metal studs with one layer of 1/2" gypsum wall board on each side, or equivalent, and shall extend to the underside of structural deck above. Demising walls shall contain 2 1/2" roll-type fiberglass sound installation. Exposed wall surfaces will be taped and patched in preparation for wall finishes.
AutoNDA by SimpleDocs
Demising Partitions. Demising partitions are provided between Tenant and other tenants, and/or Tenant and exit and/or service corridors, of the construction type shown on the Lease Outline Drawings. Partitions separating the Premises from other tenant premises will consist of metal studs only (no drywall). Tenant construction shall provide a one (1) hour separation. Partitions separating the Premises from service corridors or other Landlord areas will have dry-wall on the Landlord side only or CMU wall
Demising Partitions. Per an agreed to location as noted on Exhibit A, 8/22/12, Xxxxx Street entry location. Landlord will provide a new glass and steel entry door using similar construction methods and materials as that of the existing first floor facade, within sixty (60) days of the Commencement Date, but not as a condition to the Commencement Date. See Exhibit A. • Landlord to construct interior demising walls per on agreed to location (as noted on Exhibit A).
Demising Partitions. Building standard public corridor partitions shall be installed on the 1st floor.
Time is Money Join Law Insider Premium to draft better contracts faster.