Delivery of Electricity Sample Clauses
Delivery of Electricity. The Tenant is not entitled to supply and/or sell electricity and/or provide any of the electric services provided by the Landlord, for a consideration or otherwise except in case of delivery of electricity on the premises to a permissee and to other possessors under the agreement.
Delivery of Electricity. The Owner will deliver and the Buyer will accept delivery of Electricity and System Support Services with respect to each Unit at the applicable Delivery Point in accordance with Dispatch Instructions.
Delivery of Electricity. The Lessee may not supply and/or sell electricity and/or provide any electricity services whatsoever that have been supplied to it by the Lessor, for or without consideration and in any other manner whatsoever, unless it is a matter of the supply of electricity inside the confines of the leased property, for licensees and other occupiers, put the agreement.
Delivery of Electricity. AGL will arrange with the Distributor for the Delivery of Electricity to each Premises unless the Customer tells AGL that it already has a separate agreement with the Distributor for the Delivery of Electricity to that Premises.
Delivery of Electricity. The electric energy from the Project shall be delivered from [PROVIDER COMPANY] to [COMPANY 1] at the specifications set forth in [EXHIBIT E] and otherwise in compliance with all requirements of the Local Electric Utility.
Delivery of Electricity. Seller shall interconnect with Inter-County Energy’s System and shall deliver electricity to Inter-County Energy’s side of the Delivery Point consistent with the terms of the Interconnection Manual, which is adopted and incorporated herein in full by reference. As set forth hereinafter, Seller must provide good quality electric power within a reasonable range of voltage, frequency, flicker, harmonic currents, and power factor, including, but not limited to:
a. The electricity delivered hereunder shall be in the form of single-phase phase, at a frequency of 60-hertz, alternating current and within three percent (3%) above or below a nominal voltage of 240 volts or a nominal operating voltage to be determined by Inter-County Energy from actual operating experience. ot cause unLuinsduaalC.flBurcidtuwaetilol ns or Executive Directormisro wit EE b. Seller shall provide for proper synchronization of the Qualifying Facility with Inter- County Energy’s System such that synchronism is accomplished without causing undesirable harmful currents, surges, or voltage dips on Inter-County Energy’s System or the transmission system owned by EKPC or other interconnected utilities. sion system owned by EKPC or vide, at Seller's expense, suitable hin reasonable limits established Standard 519 and/or applicable
Delivery of Electricity. Seller shall interconnect with Shelby Energy’s System and shall deliver electricity to Shelby Energy’s side of the Delivery Point consistent with the terms of the Interconnection Manual, which is adopted and incorporated herein in full by reference. As set forth hereinafter, Seller must provide good quality electric power within a reasonable range of voltage, frequency, flicker, harmonic currents, and power factor, including, but not limited to:
a. The electricity delivered hereunder shall be in the form of single-phase phase, at a frequency of 60-hertz, alternating current and within three percent (3%) above or below a nominal voltage of 240 volts or a nominal operating voltage to be determined by Shelby Energy from actual operating experience.
b. Seller shall provide for proper synchronization of the Qualifying Facility with Shelby Energy’s System such that synchronism is accomplished without causing undesirable harmful currents, surges, or voltage dips on Shelby Energy’s System or the transmission system owned by EKPC or other interconnected utilities.
c. The electricity delivered by Seller shall not caPuUsBeLIuCnSuEsuRaVl ICfEluCctOuMatMioInSsSIOorN Executive Director disturbances on Shelby Energy’s System or the transmission system owLnienddabyC.EBKriPdCweollr other e, at Seller's expense, suitable hin reasonable limits established 519 and/or applicable standards.
Delivery of Electricity. The electric energy from the Project "Project" means an integrated system for the generation of electricity from solar energy consisting of the photovoltaic panels and associated equipment to be installed on each of the Premises in accordance with this Agreement. shall be delivered from Provider to Host at the specifications set forth in Exhibit E and otherwise in compliance with all requirements of the Local Electric Utility . [(5b) Solar electricity shall be delivered at the physical location identified in the drawings in Exhibit E, and in compliance with utility requirements.]
Delivery of Electricity. The place for delivery of the electricity shall be the Delivery Points. Without prejudice to the provisions of Part B and NAPOCOR's obligations to make fee payments, it is acknowledged that the Power Station is a despatchable provider of electricity and accordingly, subject to NAPOCOR giving the necessary notice, NAPOCOR shall only be obliged to accept power that it has requested.
Delivery of Electricity. Seller shall interconnect with Xxxxxxx Energy or EKPC’s System and shall deliver electricity to Xxxxxxx Energy or EKPC’s side of the Delivery Point consistent with the terms of the Interconnection Manual, which is adopted and incorporated herein in full by reference. As set forth hereinafter, Seller must provide good quality electric power within a reasonable range of voltage, frequency, flicker, harmonic currents, and power factor, including, but not limited to:
a. The electricity delivered hereunder shall be in the form of three-phase, at a frequency of 60-hertz, alternating current and within five percent (5%) above or below a nominal voltage of 7,200/12,470 volts or a nominal operating voltage to be determined by Xxxxxxx Energy from actual operating experience.
b. Seller shall provide for proper synchronization of the Qualifying Facility with Xxxxxxx Energy’s or EKPC’s System such that synchronism is accomplished without causing undesirable harmful currents, surges, or voltage dips on Xxxxxxx Energy’s System or the system owned by EKPC or other interconnected utilities. Should Seller fail to provide for proper synchronization of the Qualifying Facility with Xxxxxxx Energy’s or EKPC’s System, Xxxxxxx Energy reserves the right to isolate the Qualifying Facility from Xxxxxxx Energy’s system until the synchronization issue is resolved by the Seller.
c. The electricity delivered by Seller shall not cause unusual fluctuations or disturbances on Xxxxxxx Energy’s System or the system owned by EKPC or other interconnected utilities. Accordingly, the Seller shall provide, at Seller's expense, suitable apparatus which will keep such fluctuations or disturbances within reasonable limits established by Xxxxxxx Energy and EKPC in accordance with IEEE Standard 519 and/or applicable standards. Should the Qualifying Facility cause unusual fluctuations or disturbances on Xxxxxxx Energy’s System or the system owned by EKPC or other interconnected utilities, Xxxxxxx Energy reserves the right to isolate the Qualifying Facility from Xxxxxxx Energy’s system until the unusual fluctuations or disturbances are resolved by the Seller.
d. The Seller shall install a safety switch that will fully disconnect the generation circuit of its Qualifying Facility from Xxxxxxx Energy’s or EKPC’s System. The switch shall be of the visible break type which can be secured by a padlock by Xxxxxxx Energy. The disconnect switch shall be accessible to Xxxxxxx Energy and EKPC personnel at all time...