Common use of Deflection Testing Clause in Contracts

Deflection Testing. The Owner shall complete a deflection test for all new flexible storm sewers at least thirty (30) calendar days after backfilling but prior to paving. Pipe segments failing the deflection test shall be removed and replaced. Mandrel testing and laser profiling performed in accordance with OPSS.MUNI 438 and OPSS.MUNI 434, respectively, are acceptable tests for pipe deflection testing. Equipment used to perform mandrel tests shall be specifically designed for the pipe material being tested.

Appears in 2 contracts

Sources: Subdivision Agreement, Subdivision Agreement

Deflection Testing. The Owner shall complete a A deflection test shall be completed for all new flexible storm sewers at least thirty (30) calendar days after backfilling but prior to paving. Pipe segments failing the deflection test shall be removed and replaced. Mandrel testing and laser profiling performed in accordance with OPSS.MUNI 438 and OPSS.MUNI 434, respectively, are acceptable tests for pipe deflection testing. Equipment used to perform mandrel tests shall be specifically designed for the pipe material being tested.

Appears in 1 contract

Sources: Subdivision Agreement