Customer Interconnection Facilities Sample Clauses

POPULAR SAMPLE Copied 2 times
Customer Interconnection Facilities. All facilities and equipment owned and/or controlled, operated and maintained by Interconnection Customer on Interconnection Customer’s side of the Point of Interconnection identified in the appropriate appendices to the Interconnection Service Agreement and to the Interconnection Construction Service Agreement, including any modifications, additions, or upgrades made to such facilities and equipment, that are necessary to physically and electrically interconnect the Customer Facility with the Transmission System.
Customer Interconnection Facilities. All“Customer Interconnection Facilities” shall mean all facilities and equipment owned and/or controlled, operated and maintained by Interconnection Customer on Interconnection Customer’s side of the Point of Interconnection identified in the appropriate appendices to the Interconnection Service Agreement and to the Interconnection Construction Service Agreement, including any modifications, additions, or upgrades made to such facilities and equipment, that are necessary to physically and electrically interconnect the Customer Facility with the Transmission System.
Customer Interconnection Facilities. Customer shall design, procure, construct, install, own and/or control Customer Interconnection Facilities described in Appendix A, Interconnection Facilities, Network Upgrades and Distribution Upgrades, at its sole expense.
Customer Interconnection Facilities. Equipment List
Customer Interconnection Facilities. The Customer Interconnection Facilities shall include but not be limited to the following: The necessary transformers, circuit breakers, bus work, relay and protection equipment, switch gear, transmission line and supporting structures, metering and communications equipment. The conceptual layout, location, configuration and extent of Customer Interconnection Facilities is shown on the attached drawing. ▇▇▇▇▇▇▇▇ ▇ SYSTEM UPGRADES TUNICA TO TUNICA DIST. 115kV--.61 MILE 4/0 COPPER Upgrade conductor to 1272 and upgrade risers, two switches, and operating bus at Tunica Dist. 115kV Substation TUNICA DIST. TO BANKS 115kV Line--14.89 MILES, 4/0 COPPER Upgrade conductor to 1272 and upgrade risers in Banks Switching Station BANKS TO WALLS 115kV Line--9.7 Miles 4/9 COPPER AND 1/2 MILE OF 336 Upgrade conductor to 1272 and upgrade risers, two switches, operating bus, and two line bay busses at Walls Substation WALLS-DESOTO 115kV LINE--3.9 MILES OF 4/0 COPPER, .48 MILES OF 336 Upgrade conductor to 1272--Partial upgrade and partial dynamic line rating SARDIS SUBSTATION--115kV Replace two switches SENATOBIA 115kV SUBSTATION Upgrade two risers, two switches, two line bay busses and operating bus DYNAMIC LINE RATING EQUIPMENT ON: -- Senatobia to Coldwater -- Como to ▇▇▇▇▇▇▇▇ -- ▇▇▇▇▇▇▇▇ to Tunica The projects listed above are preliminary in nature and will be designed and specified more fully in accordance with Section 3.2.d. APPENDIX C TRANSFERRABLE INTERCONNECTION FACILITIES Transferrable Interconnection Facilities. Transferable Interconnection Facilities shall consist of those facilities which customer shall designate as such. The conceptual layout, location, configuration and extent of the Transferable Interconnection Facilities is shown on the attached drawing. APPENDIX D ADDITIONAL INSURED ENDORSEMENT Customer shall furnish to Company an Additional Insured Endorsement with respect to such insurance in substantially the following form: "In consideration of the premium charged, Entergy _______________, Inc. and its affiliated and associated companies are named as additional insureds with respect to liabilities arising out of Customer's use and ownership of Customer's Facilities and Interconnection Facilities." "The inclusion of more than one insured under this policy shall not operate to impair the rights of one insured against another insured and the coverages afforded by this policy will apply as though separate policies had been issued to each insured. The inclusion...
Customer Interconnection Facilities 

Related to Customer Interconnection Facilities

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner. 4.1.2 The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • CONNECTING TRANSMISSION OWNER’S INTERCONNECTION FACILITIES As depicted on the one-line diagram in Attachment 3, the Connecting Transmission Owner’s Interconnection Facilities consist of the following constructed or installed between the POI and PCO, as well as metering and telecommunications located at the ▇▇▇▇▇ Solar Collector Substation.

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall ▇▇▇▇ the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall ▇▇▇▇ such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.