Consumption of Utilities Sample Clauses

Consumption of Utilities. All consumption figures of utilities have to be understood as average values (tolerance +/- ***%) at continuous uninterrupted operation of the plant with one and the same feedstock and constant and equal supply of the utilities. ADDENDUM A-2 *** Confidential material redacted and filed separately with the Commission. The specification of feedstock and utilities has to meet the characteristics as mentioned in this Addendum. Higher and lower actual feedstock and utility consumption figures may be offset each other in terms of value. Trouble and/or adverse effects incurred because of BUYER’s failure to supply feedstock and utilities to the specifications as given therein shall not be covered by suppliers’ warranty. Crude Oil Pre-treatment Plant/Refining Plant (max. *** tpd crude oil) Consumption figures of utilities referred to *** mton of crude oil FLEX Degumming Unit (Water and Acid Degumming and Drying) -steam (4 bar) max. *** kg -phosphoric acid (85%) max. *** - *** kg -caustic soda (50%) (in case of partial neutralization only) max. *** - *** kg -caustic soda (50%) (in case of complete neutralization only) max. *** kg -citric acid (50%) max. *** kg -process water (softened water) max. *** kg -wash water (softened water) max. *** kg -control water (softened water) max. *** kg -electric power approx. *** kWh Distillative Deacidification and Deodorizing (Physical Refining) -steam (stripping steam) max. *** kg -electric power approx. *** kWh Vacuum plant - steam for booster section for deacidification max. *** kg -electric power approx. *** kWh ADDENDUM A-2 Addendum B Soy Energy, LLC Marcus, Iowa Project Scope June 8, 2007
AutoNDA by SimpleDocs
Consumption of Utilities. Tenant shall not, without Landlord’s prior written consent in each instance, exceed the capacity of the electrical system serving the Premises, and Landlord may, upon prior notice to Tenant and at Landlord’s sole cost, audit Tenant’s use of electric power to determine Tenant’s compliance herewith. If Landlord, permits such excess usage, Tenant shall pay (as Additional Rent) for the cost of such excess power, together with the cost of installing any additional risers, meters, or other facilities that may be required to furnish or measure such excess power to the Premises. Further, if Tenant requires, consumes, or uses a disproportionate amount of a supplied utility, and it is not separately metered, Tenant shall pay to Landlord as Additional Rent an equitable and reasonable charge for such additional utility use. If Tenant requires, uses, or consumes water for any purpose other than ordinary lavatory and drinking purposes (excluding restaurant-related purposes that require Tenant to have its water use separately metered), Landlord may install a water meter or submeter to measure Tenant’s water consumption. In such event, Tenant shall pay for such meter or sub-meter and at Tenant’s cost, keep such equipment in good working order and repair. Landlord and Tenant acknowledge and agree that electricity for the Premises, including, without limitation, lights, electrical outlets and the heating, ventilation and air conditioning (“HVAC”) systems serving the Premises exclusively, are separately metered. Tenant shall pay, directly to the applicable electric utility provider, all costs of electricity supplied to the Premises, including the HVAC system serving the Premises.

Related to Consumption of Utilities

  • Payment of Utilities Pay for electricity and all other utilities consumed in or relating to the Subject Unit and proportionately for the Common Portions.

  • Services and Utilities Provided that Tenant is not in default hereunder, Landlord agrees to furnish to the Premises during reasonable hours of generally recognized business days, to be determined by Landlord at his sole discretion, and subject to the rules and regulations of the Building of which the Premises are a part, electricity for normal lighting and fractional horsepower office machines, heat and air conditioning required in Landlord’s judgment for the comfortable use and occupation of the Premises, and janitorial service. Landlord shall also maintain and keep lighted the common stairs, common entries and toilet rooms in the Building of which the Premises are a part. Landlord shall not be liable for, and Tenant shall not be entitled to, any reduction of rental by reason of Landlord’s failure to furnish any of the foregoing when such failure is caused by accident, breakage, repairs, strikes, lockouts or other labor disturbances or labor disputes of any character, or by any other cause, similar or dissimilar, beyond the reasonable control of Landlord. Landlord shall not be liable under any circumstances for a loss of or injury to property, however occurring, through or in connection with or related to failure to furnish any of the foregoing. Wherever heat generating machines or equipment are used in the Premises which affect the temperature otherwise maintained by the air conditioning system, Landlord reserves the right to install supplementary air conditioning units in the Premises and the cost thereof, including the cost of installation, and the cost of operation and maintenance thereof shall be paid by Tenant to Landlord upon demand by Landlord. Tenant will not, without written consent of Landlord, use any apparatus or device in the Premises, including, but without limitation thereto, electronic data processing machines, punch card machines, and machines using in excess of 120 volts, which will in any way increase the amount of electricity usually furnished or supplied for the use of the Premises as general office space; nor connect with electric current except through existing electrical outlets in the Premises, any apparatus or device, for the purpose of using electric current. If Tenant shall require water or electric current in excess of that usually furnished or supplied for the use of the Premises as general office space, Tenant shall first procure the written consent of Landlord, which Landlord may refuse, to the use thereof and Landlord may cause a water meter or electrical current meter to be installed in the Premises, so as to measure the amount of water and electric current consumed for any such use. The cost of any such meters and of installation, maintenance and repair thereof shall be paid for by the Tenant and Tenant agrees to pay to Landlord promptly upon demand therefor by Landlord for all such water and electric current consumed as shown by said meters, at the rates charged for such services by the local public utility furnishing the same, plus any additional expense incurred in keeping account of the water and electric current so consumed. If a separate meter is not installed, such excess cost for such water and electric current will be established by an estimate made by a utility company or electrical engineer.

  • Availability of Utilities All utility services necessary for the construction of the Improvements will be available prior to the commencement of construction, and all utility services necessary for the proper operation of the Improvements for their intended purposes are available at the Leased Premises or will be available at the Leased Premises prior to the Final Disbursement Date, at commercially comparable utility rates and hook-up charges for the vicinity, including water supply, storm and sanitary sewer facilities, gas, electricity and telephone facilities. Lessee shall furnish evidence of such availability of utilities from time to time at Lessor's request.

  • Taxes and Utilities The Landlord will pay for all charges assessed against the Premises during the term of this Lease for real estate taxes, water, heat, and electricity. In the event that the Tenant installs any equipment resulting in a significant increase in the demand for power or cooling, the Tenant shall pay the additional cost of such power and cooling as an additional monthly rental payment to be determined by the Landlord. The Landlord has made arrangements for a uniform rate structure for each tenant on the Property with a communications and data provider (the word “communications” and the word “data” as used in this Lease shall include any and all telephonic or electronic transmissions from one place to another of written materials or oral communications and/or transmission of data). The Tenant shall be responsible for paying directly to the service provider, when due, such phone and data line installation charges and monthly service charges as well as the actual costs of all calls. In the event that the Tenant elects to move from the Premises to other premises within the Property, the Tenant acknowledges that it will be liable for the foregoing installation charge for each and every such move.

  • Underground Utilities Any required ground digging or subsurface work shall be done in accordance with Chapter 556, Florida Statutes. It shall be the responsibility of CONTRACTOR to have all underground utilities located before any work begins (Sunshine State One Call 0-000-000-0000). The repairs of any damaged underground utilities as a result of the work being performed by CONTRACTOR shall be the responsibility of CONTRACTOR. The proper utility company shall be contacted immediately to expedite the repairs, if damage has occurred. CONTRACTOR will notify the COUNTY and provide a written explanation of the incident within two (2) days of the damage to any underground utilities.

  • Utilities The Landlord shall provide the following utilities and services to the Tenant: _ _. Any other utilities or services not mentioned will be the responsibility of the Tenant.

  • Local Utility Services XOOM is an independent retail marketer of natural gas and is not affiliated with your local utility. Your local utility will continue to deliver your natural gas, read your meter, send your bill, and make necessary repairs. Your local utility will also respond to emergencies and provide other basic utility services as required. XOOM is not an agent of your local utility and your utility will not be liable for any of XOOM’s acts, omissions, or representations.

  • Electricity 14.01 Tenant shall obtain electricity for the Demised Premises on a direct meter basis, Tenant shall be responsible for and pay to the applicable utility all charges for electricity as measured by such meter. Landlord shall not in any way be liable or responsible to Tenant for any loss or damage or expense which Tenant may sustain or incur if either the quantity or character of electric service is changed or is no longer available or suitable for Tenant’s requirements. Any additional riser or risers to supply Tenant’s electrical requirements, upon written request to Tenant, will be installed by Landlord, at the sole cost and expense of Tenant, unless, in Landlord’s reasonable judgment, the same will cause permanent damage or injury to the Building or the Demised Premises or cause or create a dangerous or hazardous condition or interfere with or disturb other tenants or occupants. In addition to the installation of such riser or risers, Landlord will also at the sole cost and expense of Tenant, install all other equipment proper and necessary in connection therewith subject to the aforesaid terms and conditions. Tenant covenants and agrees that at all times its use of electric current shall never exceed the capacity of the feeders to the Building or the risers or wiring installation which Landlord represents is sufficient for ordinary office use. It is further covenanted and agreed by the Tenant that all the aforesaid costs and expenses are chargeable and collectible as Additional Rent and shall be paid by the Tenant to the Landlord within ten (10) days after the rendering of any xxxx or statement to the Tenant therefor. Tenant shall make no alterations or additions to the electric equipment and/or appliances without the prior written consent of Landlord in each instance, which consent shall not be unreasonably withheld, conditioned or delayed. Notwithstanding anything to the contrary herein, should electric service be interrupted for a period of more than five (5) consecutive business days through the sole fault of Landlord so as to prevent Tenant from using at least seventy-five (75%) percent of the Demised Premises, Fixed Rent shall xxxxx until such service resumes and Tenant is able to resume the use of at least seventy-five (75%) percent of the Demised Premises. Should such service interruption prevent Tenant from using at least seventy-five (75%) of the Demised Premises for more than sixty (60) days and be due to the sole fault of Landlord, Tenant shall have the right to terminate this Lease by giving written notice to Landlord no later than the seventieth (70th) consecutive day and vacating no later than the ninetieth (90th) consecutive day. TIME BEING OF THE ESSENCE for Tenant as to both dates.

  • COMMON UTILITIES Expenses for serving/supply of common facilities and utilities and all charges incidental thereto.

  • Electric If Customer has selected an Electricity Fixed Rate on the Application, Customer’s Price will be based on the Fixed Rate(s) which includes Local and State taxes, Gross Receipts Tax (GRT), PJM Adjustment (defined below) charges and adjustments and Utility applied charges and/or fees related to generation, plus the Administration Charge, which includes, Electricity Balancing Amount and third party utility and billing charges. Customer understands and agrees that included in the Administration Charge is the cost of the Energy Balancing Amount (defined below). Customer understands that in order for RITERATE ENERGY to be able to supply Energy to its existing and prospective customers, RITERATE ENERGY enters into supply arrangements to meet the forecasted consumption of its various groups of customers. These forecasts are based on historical data, load shapes and/or estimates. To the extent that actual pooled consumption of RITERATE ENERGY’s Energy customers varies from supply arrangements and/or Customer’s Utility delivery requirements, RITERATE ENERGY incurs a cost in balancing and settling its supply arrangements with such pooled consumption. To ensure a fixed all-inclusive Rate, RITERATE ENERGY has included in the Administration charge, the Energy Balancing Amount, to balance and settle the variance between pooled consumption and supply arrangements (the “Energy Balancing Amount”). In respect of Electricity, Customer understands that there are certain estimated pass through costs, made up of charges to RITERATE ENERGY by the PJM Interconnection (“PJM”) and/or Customer’s Utility, including but not limited to ancillary service charges, the cost of unaccounted for electricity, capacity charges and any replacement or recharacterization of these charges. In this regard, the “PJM Adjustment”, is included in the Fixed Price Rate. Customer acknowledges and agrees that by entering into this Agreement, Customer will not be eligible to receive any net metering credits and other incentives to which Customer would otherwise be entitled. Further, included in the Rate are the amounts charged or billed to RITERATE ENERGY or Customer by Customer’s Utility, the PUC or any other regulatory or government entity, including any taxes, delivery, regulated transmission, regulated distribution, pipeline, compressor fuel, uplift, congestion, locational marginal pricing, invoice market participant, service, billing, or similar or related changes and any, deposits, interest or late payment fees or other amounts in connection with the supply and delivery of Energy to the Premises (collectively, “Regulatory Charges”). Customer agrees to pay the monthly Administration charge for Energy supply (the “Administration” charge).

Time is Money Join Law Insider Premium to draft better contracts faster.