{"component": "clause", "props": {"groups": [{"samples": [{"hash": "hOWOTDoumby", "uri": "/contracts/hOWOTDoumby#casework", "label": "Sublease (Assembly Biosciences, Inc.)", "score": 34.8507871321, "published": true}, {"hash": "hReCzwwxWae", "uri": "/contracts/hReCzwwxWae#casework", "label": "Lease (Fluidigm Corp)", "score": 30.3442847365, "published": true}], "snippet_links": [{"key": "compressed-air", "type": "clause", "offset": [196, 210]}, {"key": "hot-and-cold-water", "type": "clause", "offset": [393, 411]}, {"key": "factory-installed", "type": "clause", "offset": [591, 608]}], "size": 6, "snippet": "Labs will be furnished with modular, mobile metal laboratory casework manufactured by iLab, Inc. Countertops will be chemical resistant epoxy/phenolic resin. Island benches shall be pre-piped for Compressed Air and Lab Vacuum with quick disconnect connections located above the ceiling. Benches with sinks will have a single basin epoxy sink (21\u201d x 15\u201d x 10\u201d deep). Sink cabinets shall have a hot and cold water mixing faucet with a counter mounted eyewash. Sinks at island benches will have a stainless-steel glassware pegboard with drip tray and drain hose. Benches will be pre-wired with factory installed single channel raceways for power. Receptacles will be GFI at wet benches and color coded for normal (grey) and emergency (red) power uses.", "hash": "a8bdae0c4c9fb9ead0beedd6ad9089dd", "id": 1}, {"samples": [{"hash": "fb6rC3qHCcY", "uri": "/contracts/fb6rC3qHCcY#casework", "label": "Framework Agreement", "score": 27.9604197909, "published": true}, {"hash": "ecFvUA0HHOM", "uri": "/contracts/ecFvUA0HHOM#casework", "label": "Framework Agreement", "score": 27.9604197909, "published": true}, {"hash": "7oOGMbtXcJz", "uri": "/contracts/7oOGMbtXcJz#casework", "label": "Framework Agreement", "score": 21.5968514716, "published": true}], "snippet_links": [{"key": "making-decisions", "type": "clause", "offset": [26, 42]}, {"key": "the-director", "type": "clause", "offset": [121, 133]}, {"key": "appropriate-staff", "type": "definition", "offset": [165, 182]}, {"key": "the-attorney-general", "type": "definition", "offset": [199, 219]}, {"key": "responsible-for", "type": "clause", "offset": [223, 238]}, {"key": "decision-making", "type": "definition", "offset": [268, 283]}], "size": 5, "snippet": "The CPS is independent in making decisions whether or not to prosecute a case. Those decisions are the responsibility of the Director, who may delegate authority to appropriate staff within the CPS. The Attorney General is responsible for safeguarding the independent decision making of the CPS.", "hash": "c10adc5260d335904c2a3bf4387fa2d6", "id": 2}, {"samples": [{"hash": "cPOQKIUq6vN", "uri": "/contracts/cPOQKIUq6vN#casework", "label": "Office Lease (Arcadia Biosciences, Inc.)", "score": 26.1279945243, "published": true}, {"hash": "42dRIeUxNDY", "uri": "/contracts/42dRIeUxNDY#casework", "label": "Office Lease (Arcadia Biosciences, Inc.)", "score": 25.9719370294, "published": true}], "snippet_links": [{"key": "exposed-surfaces", "type": "definition", "offset": [20, 36]}, {"key": "as-selected", "type": "definition", "offset": [126, 137]}, {"key": "by-owner", "type": "definition", "offset": [138, 146]}, {"key": "construction-materials", "type": "clause", "offset": [184, 206]}, {"key": "counter-tops", "type": "clause", "offset": [383, 395]}, {"key": "particle-board", "type": "definition", "offset": [426, 440]}, {"key": "plastic-laminate", "type": "clause", "offset": [446, 462]}, {"key": "unless-otherwise-indicated", "type": "clause", "offset": [522, 548]}, {"key": "comply-with", "type": "clause", "offset": [556, 567]}, {"key": "refer-to", "type": "definition", "offset": [600, 608]}, {"key": "wic-manual", "type": "clause", "offset": [609, 619]}], "size": 3, "snippet": "1. Exposed and semi-exposed surfaces, wood veneer Rift Cut-Transparent (Stain) finish.\n2. Color of transparent (stain) finish as selected by Owner and/or Architect.\n3. Refer above for construction materials not otherwise noted.\n4. All shelves to 32\u201d long shall be \u00be\u201d thick minimum and all shelves 33\u201d and longer shall be 1\u201d thick minimum. Edge band full perimeter of all shelves.\n5. Counter tops shall be a one piece \u00be\u201d thick particle board with plastic laminate overlay with 4\u201d high top mount splash and self edge front, unless otherwise indicated. Shall comply with WIC Premium Grade construction, refer to WIC Manual of Millwork, Section 26.", "hash": "731d1d4974f8a8bcaa53ab56759c9e30", "id": 3}, {"samples": [{"hash": "gUNaYWEuQl5", "uri": "/contracts/gUNaYWEuQl5#casework", "label": "Sub Sublease (Reliant Technologies Inc)", "score": 21.0, "published": true}], "snippet_links": [{"key": "plastic-laminate", "type": "clause", "offset": [61, 77]}, {"key": "not-to-exceed", "type": "clause", "offset": [418, 431]}, {"key": "to-landlord", "type": "clause", "offset": [1022, 1033]}, {"key": "for-approval", "type": "definition", "offset": [1034, 1046]}, {"key": "door-frame", "type": "clause", "offset": [1143, 1153]}, {"key": "tenant-and-landlord", "type": "clause", "offset": [1347, 1366]}, {"key": "wired-glass", "type": "definition", "offset": [1403, 1414]}, {"key": "where-required-by", "type": "clause", "offset": [1415, 1432]}, {"key": "demising-walls", "type": "clause", "offset": [1458, 1472]}, {"key": "both-sides", "type": "definition", "offset": [1849, 1859]}, {"key": "return-air", "type": "definition", "offset": [1904, 1914]}, {"key": "interior-walls", "type": "definition", "offset": [1932, 1946]}, {"key": "ceiling-height", "type": "definition", "offset": [1947, 1961]}, {"key": "acoustical-ceiling", "type": "clause", "offset": [1985, 2003]}, {"key": "level-4", "type": "definition", "offset": [2111, 2118]}, {"key": "light-fixtures", "type": "definition", "offset": [2126, 2140]}, {"key": "other-fixtures", "type": "clause", "offset": [2203, 2217]}, {"key": "accent-lighting", "type": "definition", "offset": [2292, 2307]}, {"key": "conference-rooms", "type": "clause", "offset": [2311, 2327]}, {"key": "reception-areas", "type": "clause", "offset": [2332, 2347]}, {"key": "as-required-by", "type": "clause", "offset": [2386, 2400]}, {"key": "by-tenant", "type": "clause", "offset": [2423, 2432]}, {"key": "private-offices", "type": "clause", "offset": [2487, 2502]}, {"key": "electrical-outlets", "type": "clause", "offset": [2522, 2540]}, {"key": "telephone-and-data", "type": "clause", "offset": [2546, 2564]}, {"key": "duplex-outlets", "type": "clause", "offset": [2644, 2658]}, {"key": "based-on", "type": "clause", "offset": [2762, 2770]}, {"key": "the-foregoing", "type": "definition", "offset": [2804, 2817]}, {"key": "approval-by-landlord", "type": "clause", "offset": [2853, 2873]}], "size": 3, "snippet": "Base cabinets with Countertops \u2013 Flush overlay construction, plastic laminate exteriors, drawers over doors, 6\u201d drawer fronts, one selply shelf adjustable on 32 mm pins, 4\u201d back splash, 4\u201d painted plywood base, locking rail behind face frame between doors and drawers (no locks, unless specifically requested), 2\u2019-3\u201d deep, 3\u2019-0\u201d high, polished chrome wire pulls, hinges adjustable with 170 degrees opening, shelf span not to exceed 32\u201d, countertops to be plywood under plastic laminate. Wall Cabinets \u2013 Flush overlay construction laminate exteriors, mounted from 4\u2019-8\u201d above finished floor to 7\u2019-6\u201d above finished floor, seal top with backing material, two seply shelves adjustable on 32 mm pins, 3\u201d apron at bottom, brushed chrome wire pulls, hinges adjustable with 170 degree opening, shelf span not to exceed 32\u201d. Standard Plastics Laminates \u2013 Formica, Wilsonart or Nevamar. Doors: 3\u2019-0\u201d x 9\u20190\u201d x 1-3/4\u201d solid core, prefinished wood (wood veneer or paint grade, rated as required). Proposed upgrades shall be submitted to Landlord for approval. Frames: Brushed aluminum with clear finish (rated as required). Sidelight frames integral with door frame 2\u2019-0\u201d x 9\u2019-0\u201d. Hardware: Schlage lever hardware. Two pair butts per door. Dome floor stops. Closers, automatic flush bolts, astragals, and coordinators with finish to be mutually acceptable to Tenant and Landlord. Glass: \u00bc\u201d clear tempered or square wired glass where required by code. Corridor walls and demising walls for bathrooms, elevator pits and stairwell enclosures/1-Hr. construction with 3 5/8\u201d 25 gauge metal studs, 24\u201d on center to underside of structure with 5/8\u201d sheetrock on each side and R-11 batt insulation full height. Tenant demising walls/full height (slab to structure) 3 5/8\u201d 25 gauge metal studs, 24\u201d on center with R-11 insulation and 5/8\u201d type \u201cX\u201d sheetrock full height both sides (the height of the wall may be adjusted for return air plenium). Tenant interior walls/ceiling height (floor to underside of acoustical ceiling), 3 5/8\u201d 25 gauge studs, 24\u201d on center with 5/8\u201d sheetrock on each side and J-mold at top. Finish: Smooth (level 4) wall. Light fixtures: 2\u2019 x 4\u2019 three lamp fixtures with 18 cell parabolic lenses or other fixtures mutually acceptable to Tenant and Landlord. Downlight and wall washers as accent lighting in conference rooms and reception areas as appropriate. Exit lights: Quantity as required by code, to be specified by Tenant subject to Landlord\u2019s approval. Outlets and switches: Private offices receive two duplex electrical outlets, two telephone and data outlets (ring/string) and one dual light switch. Conference rooms receive four duplex outlets, two telephone and data outlets (ring/string) and one dual light switch. All other rooms are addressed based on specific layouts. Any changes to the foregoing specifications shall be subject to approval by Landlord.", "hash": "0178fb8ee5db124dba08460d53c0776c", "id": 4}, {"samples": [{"hash": "6LT3JiMdhD1", "uri": "/contracts/6LT3JiMdhD1#casework", "label": "Sublease (CARGO Therapeutics, Inc.)", "score": 34.8453114305, "published": true}, {"hash": "lwGm6Lqm0dr", "uri": "/contracts/lwGm6Lqm0dr#casework", "label": "Sublease (CARGO Therapeutics, Inc.)", "score": 34.7987679671, "published": true}], "snippet_links": [{"key": "in-general", "type": "clause", "offset": [224, 234]}, {"key": "complying-with", "type": "clause", "offset": [561, 575]}, {"key": "compressed-air", "type": "clause", "offset": [753, 767]}, {"key": "hot-and-cold-water", "type": "clause", "offset": [951, 969]}, {"key": "lab-area", "type": "definition", "offset": [1150, 1158]}, {"key": "the-code", "type": "clause", "offset": [1200, 1208]}, {"key": "factory-installed", "type": "clause", "offset": [1267, 1284]}, {"key": "standby-power", "type": "definition", "offset": [1324, 1337]}], "size": 2, "snippet": "Labs shall be furnished with modular, mobile metal laboratory casework manufactured by iLab, Inc. Standard countertop height is +37\u201d AFF; with a mixture of 2/3\u2019s being fixed height, and 1/3 being manually adjustable height, in general. Modular mobile pedestals shall be 50% drawer & door and 50% all drawers, and there shall be one (1) provided per each modular bench or table. Countertops shall be 1\u201d thick chemical resistant epoxy/phenolic resin: Trespa TopLab Plus, by Trespa; color: Slate Grey. All lab casework shall be 18 gauge/20 gauge cold rolled steel complying with ASTM A 1008/A 1008M with powder coated finish, color: \u201cE-9132 Appliance White\u201d. All hardware shall be brushed aluminum flush style finish. Island benches shall be pre-piped for Compressed Air and Lab Vacuum with quick disconnect connections located above the ceiling. Benches with sinks shall have a single basin epoxy sink (25\u201d x 15\u201d x 10\u201d deep). Sink cabinets shall have a hot and cold water mixing faucet with a counter mounted eyewash. Sinks at island benches shall have a stainless-steel glassware pegboard with drip tray and drain hose. At least one (1) lab sink per \u201clab area\u201d shall be ADA height (+34\u201d AFF), to meet the Code-required \u201cSIDE APPROACH\u201d. Benches shall be pre-wired with factory installed single channel raceways for normal and standby power. Typical power design at island benches is as follows:", "hash": "aa508b90531b6cc2b8cc9b95ff9b1bf0", "id": 5}, {"samples": [{"hash": "aRAZ1qvgi3b", "uri": "/contracts/aRAZ1qvgi3b#casework", "label": "Sublease (ConforMIS Inc)", "score": 26.3853524983, "published": true}, {"hash": "8BpYbNKX444", "uri": "/contracts/8BpYbNKX444#casework", "label": "Sublease (ConforMIS Inc)", "score": 26.2128678987, "published": true}], "snippet_links": [{"key": "plastic-laminate", "type": "clause", "offset": [0, 16]}, {"key": "lunch-room", "type": "clause", "offset": [20, 30]}, {"key": "gathering-area", "type": "definition", "offset": [191, 205]}, {"key": "storage-areas", "type": "clause", "offset": [512, 525]}], "size": 2, "snippet": "Plastic Laminate at Lunch Room: Plastic-laminate-covered particleboard; reveal construction; adjustable shelves; European-hinges. \u00b7 Countertops: Solid surfacing. \u00b7 Countertops at Main Coffee Gathering Area: Stone or concrete. \u00b7 There is to be 140 linear feet of tower cabinets and 140 linear feet of upper cabinets including those in the lunchroom, the coffee areas, and in the fax/copier rooms. Upper cabinets will be included in all coffee areas, plastic laminate faced to match tower cabinets. Copy areas and Storage areas will include laminate-covered open adjustable shelving above lower cabinets, to be 1\u2019-0\u2019 deep on heavy-duty adjustable hardware.", "hash": "67327eceeee837ca709f4b57076bb72e", "id": 6}, {"samples": [{"hash": "lzgpQ8G0AcI", "uri": "/contracts/lzgpQ8G0AcI#casework", "label": "Collaboration Agreement", "score": 32.9677710604, "published": true}, {"hash": "jCx7H2Rij4n", "uri": "/contracts/jCx7H2Rij4n#casework", "label": "Collaboration Agreement", "score": 32.4312470147, "published": true}], "snippet_links": [{"key": "service-type", "type": "definition", "offset": [4, 16]}, {"key": "service-provided", "type": "definition", "offset": [27, 43]}, {"key": "london-travelwatch", "type": "definition", "offset": [66, 84]}, {"key": "provider-contact", "type": "definition", "offset": [89, 105]}, {"key": "client-contact", "type": "clause", "offset": [122, 136]}, {"key": "service-objective", "type": "clause", "offset": [158, 175]}, {"key": "handling-services", "type": "definition", "offset": [225, 242]}, {"key": "relate-to", "type": "definition", "offset": [256, 265]}, {"key": "meaning-of", "type": "clause", "offset": [295, 305]}, {"key": "act-1993", "type": "clause", "offset": [354, 362]}, {"key": "as-amended", "type": "definition", "offset": [364, 374]}, {"key": "requests-for-information", "type": "clause", "offset": [377, 401]}, {"key": "freedom-of-information-act-2000", "type": "clause", "offset": [417, 448]}, {"key": "the-general-data-protection-regulations", "type": "clause", "offset": [507, 546]}, {"key": "service-scope", "type": "clause", "offset": [557, 570]}, {"key": "set-out", "type": "definition", "offset": [617, 624]}, {"key": "dispute-resolution", "type": "definition", "offset": [829, 847]}, {"key": "uk-gdpr", "type": "definition", "offset": [1089, 1096]}, {"key": "the-contract", "type": "definition", "offset": [1175, 1187]}, {"key": "customer-contact-centre", "type": "clause", "offset": [1197, 1220]}, {"key": "the-director", "type": "clause", "offset": [1227, 1239]}, {"key": "supervision-of-the", "type": "clause", "offset": [1246, 1264]}, {"key": "and-representation", "type": "clause", "offset": [1317, 1335]}, {"key": "policy-issues", "type": "clause", "offset": [1403, 1416]}, {"key": "it-platform", "type": "definition", "offset": [1556, 1567]}, {"key": "privacy-policy", "type": "definition", "offset": [1580, 1594]}, {"key": "web-form", "type": "definition", "offset": [1615, 1623]}, {"key": "continuing-contract", "type": "clause", "offset": [1626, 1645]}, {"key": "management-service", "type": "definition", "offset": [1694, 1712]}, {"key": "reports-to", "type": "definition", "offset": [1778, 1788]}, {"key": "management-team", "type": "definition", "offset": [1809, 1824]}, {"key": "agreed-format", "type": "definition", "offset": [1869, 1882]}, {"key": "key-performance-indicators", "type": "definition", "offset": [1887, 1913]}, {"key": "other-issues", "type": "definition", "offset": [1917, 1929]}, {"key": "in-respect-of", "type": "clause", "offset": [1943, 1956]}, {"key": "the-service", "type": "clause", "offset": [1957, 1968]}, {"key": "working-days", "type": "clause", "offset": [2130, 2142]}, {"key": "quality-measures", "type": "definition", "offset": [2375, 2391]}, {"key": "first-half", "type": "definition", "offset": [2399, 2409]}, {"key": "business-year", "type": "definition", "offset": [2479, 2492]}, {"key": "satisfaction-survey", "type": "definition", "offset": [2688, 2707]}], "size": 2, "snippet": "(a) Service type This is a service provided to Transport Focus by London TravelWatch\n(b) Provider contact \u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587\n(c) Client contact \u2587\u2587\u2587\u2587\u2587 \u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\u2587\n(d) Service objective Provide Transport Focus with complaint and issue handling services such as they relate to passenger contact within the meaning of parts 1, 2 and 7A of section 76 of the Railways Act 1993 (as amended); requests for information made under the Freedom of Information Act 2000; or requests by individuals exercising their rights under the General Data Protection Regulations 2018.\n(e) Service scope \u2022 Ensure that the passenger contact duties as set out in the statutes referred to above are satisfactorily discharged, to whatever extent representations are passed to the third-party Rail Ombudsman (because they are \u2018in-scope\u2019 of that Scheme) for effective dispute resolution; \u2022 Ensure that passenger issues not passed to the Rail Ombudsman (because they are \u2018out-of-scope\u2019 of that Scheme) are addressed promptly and effectively through liaison with the appropriate Transport Focus staff member(s); \u2022 Manage FOIA and UK GDPR requests as set out in the Transport Focus Information Risk Handbook \u2022 Manage the contract with the customer contact centre under the director level supervision of the Transport Focus Directors \u2022 External representation and representation to at relevant industry meetings and forums \u2022 Identifying relevant policy issues and trends arising from casework and ensuring that these are considered by colleagues.\n(f) Client inputs required \u2022 Supporting cloud-based IT platform \u2022 Compliant privacy policy \u2022 Accurately routed web form \u2022 Continuing contract with Ventrica (or any contact centre or contact management service / programme contracted by Transport Focus)\n(g) Reporting Provide reports to the Transport Focus Management Team and Passenger Contact Group quarterly in an agreed format\n(h) Key performance indicators or other issues / principles in respect of the Service The key performance indicators for this service are as follows: PAS1 Calls to Ventrica are answered within 20 seconds >85% PAS2 Appeals acknowledged within five working days 100% PAS3 Appeals closed within 20 working days >80% PAS4 Appeals closed within 35 working days >95% PAS5 Enquiries closed within 20 working days >95% PAS6 Complaints about Transport Focus <01% Transport Focus will develop a set of quality measures in the first half of 2021/22 to be introduced from Q3 2021/22 for the remainder of the business year. The measures, covering an agreed set of both qualitative and quantitative case handing outcomes between TF and LTW, will be assessed against feedback from passengers gathered by a case handling satisfaction survey.\n(i) Consideration \u2022 Strategic Value", "hash": "d84d2d5972c3f9ad6f5dc78e85827f13", "id": 7}, {"samples": [{"hash": "iTStsRannxN", "uri": "/contracts/iTStsRannxN#casework", "label": "Office Lease Agreement (Cray Inc)", "score": 21.0, "published": true}], "snippet_links": [], "size": 2, "snippet": "Elevations, sections and details for all built-in casework", "hash": "8fb14744f18655df2ad20c860c6a5454", "id": 8}, {"samples": [{"hash": "gUNaYWEuQl5", "uri": "/contracts/gUNaYWEuQl5#casework", "label": "Sub Sublease (Reliant Technologies Inc)", "score": 21.0, "published": true}], "snippet_links": [{"key": "plastic-laminate", "type": "clause", "offset": [61, 77]}, {"key": "not-to-exceed", "type": "clause", "offset": [418, 431]}], "size": 1, "snippet": "Base cabinets with Countertops - Flush overlay construction, plastic laminate exteriors, drawers over doors, 6\u201d drawer fronts, one selply shelf adjustable on 32 mm pins, 4\u201d back splash, 4\u201d painted plywood base, locking rail behind face frame between doors and drawers (no locks, unless specifically requested), 2\u2019-3\u201d deep, 3\u2019-0\u201d high, polished chrome wire pulls, hinges adjustable with 170 degrees opening, shelf span not to exceed 32\u201d, countertops to be plywood under plastic laminate. Wall Cabinets - Flush overlay construction laminate exteriors, mounted from 4\u2019-8\u201d above finished floor to 7\u2019-6\u201d above finished floor, seal top with backing material, two selply shelves adjustable on 32 mm pins, 3\u201d apron at bottom, brushed chrome wire pulls, hinges adjustable with 170 degree opening, shelf span not to exceed 32\u201d. Standard Plastics Laminates - Formica, Wilson art or Nevamar.", "hash": "e43d191ffbd82048e0421e3c1039e5d5", "id": 9}, {"samples": [{"hash": "91EbAECtfFv", "uri": "/contracts/91EbAECtfFv#casework", "label": "Lease Agreement (Pc Connection Inc)", "score": 23.8295687885, "published": true}], "snippet_links": [{"key": "plastic-laminate", "type": "clause", "offset": [15, 31]}, {"key": "serving-area", "type": "definition", "offset": [57, 69]}, {"key": "prep-area", "type": "definition", "offset": [86, 95]}, {"key": "office-area", "type": "definition", "offset": [109, 120]}], "size": 1, "snippet": "a. Install new plastic laminate countertops in cafeteria serving area\nb. Install food prep area in 2nd Floor Office area", "hash": "d942431557e0aabd9e983d1334dbaa62", "id": 10}], "next_curs": "ClESS2oVc35sYXdpbnNpZGVyY29udHJhY3Rzci0LEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2IhFjYXNld29yayMwMDAwMDAwYQyiAQJlbhgAIAA=", "clause": {"title": "Casework", "size": 49, "parents": [["paint", "PAINT"], ["miscellaneous", "Miscellaneous"], ["illuminated-exit-signs", "ILLUMINATED EXIT SIGNS"], ["approvals", "Approvals"], ["services", "SERVICES"]], "children": [["drawer-boxes", "Drawer Boxes"], ["", ""], ["wiring-devices", "WIRING DEVICES"], ["thermostats", "THERMOSTATS"], ["general", "GENERAL"]], "id": "casework", "related": [["interior", "Interior", "Interior"], ["electrical-items", "Electrical Items", "Electrical Items"], ["installations", "Installations", "Installations"], ["lighting", "Lighting", "Lighting"], ["plumbing", "Plumbing", "Plumbing"]], "related_snippets": [], "updated": "2025-07-07T12:35:11+00:00"}, "json": true, "cursor": ""}}