Casework. Base cabinets with Countertops – Flush overlay construction, plastic laminate exteriors, drawers over doors, 6” drawer fronts, one selply shelf adjustable on 32 mm pins, 4” back splash, 4” painted plywood base, locking rail behind face frame between doors and drawers (no locks, unless specifically requested), 2’-3” deep, 3’-0” high, polished chrome wire pulls, hinges adjustable with 170 degrees opening, shelf span not to exceed 32”, countertops to be plywood under plastic laminate. Wall Cabinets – Flush overlay construction laminate exteriors, mounted from 4’-8” above finished floor to 7’-6” above finished floor, seal top with backing material, two seply shelves adjustable on 32 mm pins, 3” apron at bottom, brushed chrome wire pulls, hinges adjustable with 170 degree opening, shelf span not to exceed 32”. Standard Plastics Laminates – Formica, Wilsonart or Nevamar. Doors: 3’-0” x 9’0” x 1-3/4” solid core, prefinished wood (wood veneer or paint grade, rated as required). Proposed upgrades shall be submitted to Landlord for approval. Frames: Brushed aluminum with clear finish (rated as required). Sidelight frames integral with door frame 2’-0” x 9’-0”. Hardware: Schlage lever hardware. Two pair butts per door. Dome floor stops. Closers, automatic flush bolts, astragals, and coordinators with finish to be mutually acceptable to Tenant and Landlord. Glass: ¼” clear tempered or square wired glass where required by code. Corridor walls and demising walls for bathrooms, elevator pits and stairwell enclosures/1-Hr. construction with 3 5/8” 25 gauge metal studs, 24” on center to underside of structure with 5/8” sheetrock on each side and R-11 batt insulation full height. Tenant demising walls/full height (slab to structure) 3 5/8” 25 gauge metal studs, 24” on center with R-11 insulation and 5/8” type “X” sheetrock full height both sides (the height of the wall may be adjusted for return air plenium). Tenant interior walls/ceiling height (floor to underside of acoustical ceiling), 3 5/8” 25 gauge studs, 24” on center with 5/8” sheetrock on each side and J-mold at top. Finish: Smooth (level 4) wall. Light fixtures: 2’ x 4’ three lamp fixtures with 18 cell parabolic lenses or other fixtures mutually acceptable to Tenant and Landlord. Downlight and wall washers as accent lighting in conference rooms and reception areas as appropriate. Exit lights: Quantity as required by code, to be specified by Tenant subject to Landlord’s approval. Outlets and switches: Private offices receive two duplex electrical outlets, two telephone and data outlets (ring/string) and one dual light switch. Conference rooms receive four duplex outlets, two telephone and data outlets (ring/string) and one dual light switch. All other rooms are addressed based on specific layouts. Any changes to the foregoing specifications shall be subject to approval by Landlord.
Appears in 1 contract
Casework. Base cabinets with Countertops – - Flush overlay construction, plastic laminate exteriors, drawers over doors, 6” " drawer fronts, one selply shelf adjustable on 32 mm pins, 4” " back splash, 4” " painted plywood base, locking rail behind face frame between doors and drawers (no locks, unless specifically requested), 2’-3” 2'-3" deep, 3’-0” 3'-0" high, polished chrome wire pulls, hinges adjustable with 170 degrees opening, shelf span not to exceed 32”", countertops to be plywood under plastic laminate. Wall Cabinets – - Flush overlay construction laminate exteriors, mounted from 4’-8” 4'-8" above finished floor to 7’-6” 7'-6" above finished floor, seal top with backing material, two seply selply shelves adjustable on 32 mm pins, 3” " apron at bottom, brushed chrome wire pulls, hinges adjustable with 170 degree opening, shelf span not to exceed 32”". Standard Plastics Laminates – - Formica, Wilsonart or Nevamar. DOORS, FRAMES, HARDWARE & GLASS: Doors: 3’-0” 3'-0" x 9’0” 9'0" x 1-3/4” " solid core, prefinished wood (wood veneer or paint grade, rated as required). Proposed upgrades shall be submitted to Landlord for approval. Frames: Brushed aluminum with clear finish (rated as required). Sidelight frames integral with door frame 2’-0” 2'-0" x 9’-0”9'-0". Hardware: Schlage lever hardware. Two pair butts per door. Dome floor stops. Closers, automatic flush bolts, astragals, and coordinators with finish to be mutually acceptable to Tenant and Landlord. Glass: ¼” 1/4" clear tempered or square wired glass where required by code. METAL FRAMING & DRYWALL: Corridor walls and demising walls for bathrooms, elevator pits and stairwell enclosures/1-Hr. construction with 3 5/8” " 25 gauge metal studs, 24” " on center to underside of structure with 5/8” " sheetrock on each side and R-11 batt insulation full height. Tenant demising walls/full height (slab to structure) 3 5/8” " 25 gauge metal studs, 24” " on center with R-11 insulation and 5/8” " type “"X” " sheetrock full height both sides (the height of the wall may be adjusted for return air plenium). Tenant interior walls/ceiling height (floor to underside of acoustical ceiling), 3 5/8” " 25 gauge studs, 24” " on center with 5/8” " sheetrock on each side and J-mold at top. Finish: Smooth (level 4) wall. Light fixtures: 2’ x 4’ three lamp fixtures with 18 cell parabolic lenses or other fixtures mutually acceptable to Tenant and Landlord. Downlight and wall washers as accent lighting in conference rooms and reception areas as appropriate. Exit lights: Quantity as required by code, to be specified by Tenant subject to Landlord’s approval. Outlets and switches: Private offices receive two duplex electrical outlets, two telephone and data outlets (ring/string) and one dual light switch. Conference rooms receive four duplex outlets, two telephone and data outlets (ring/string) and one dual light switch. All other rooms are addressed based on specific layouts. Any changes to the foregoing specifications shall be subject to approval by Landlord.
Appears in 1 contract
Casework. Base cabinets with Countertops – - Flush overlay construction, plastic laminate exteriors, drawers over doors, 6” " drawer fronts, one selply shelf adjustable on 32 mm pins, 4” " back splash, 4” " painted plywood base, locking rail behind face frame between doors and drawers (no locks, unless specifically requested), 2’-3” 2'-3" deep, 3’-0” 3'-0" high, polished chrome wire pulls, hinges adjustable with 170 degrees opening, shelf span not to exceed 32”", countertops to be plywood under plastic laminate. Wall Cabinets – - Flush overlay construction laminate exteriors, mounted from 4’-8” 4'- 8" above finished floor to 7’-6” 7'-6" above finished floor, seal top with backing material, two seply selply shelves adjustable on 32 mm pins, 3” " apron at bottom, brushed chrome wire pulls, hinges adjustable with 170 degree opening, shelf span not to exceed 32”". Standard Plastics Laminates – - Formica, Wilsonart or Nevamar. DOORS, FRAMES, HARDWARE & GLASS: Doors: 3’-0” 3'-0" x 9’0” 9'0" x 1-3/4” " solid core, prefinished wood (wood veneer or paint grade, rated as required). Proposed upgrades shall be submitted to Landlord for approval. Frames: Brushed aluminum with clear finish (rated as required). Sidelight frames integral with door frame 2’-0” 2'-0" x 9’-0”9'-0". Hardware: Schlage lever hardware. Two pair butts per door. Dome floor stops. Closers, automatic flush bolts, astragals, and coordinators with finish to be mutually acceptable to Tenant and Landlord. Glass: ¼” 1/4" clear tempered or square wired glass where required by code. METAL FRAMING & DRYWALL: Corridor walls and demising walls for bathrooms, elevator pits and stairwell enclosures/1-Hr. construction with 3 5/8” " 25 gauge metal studs, 24” " on center to underside of structure with 5/8” " sheetrock on each side and R-11 batt insulation full height. Tenant demising walls/full height (slab to structure) 3 5/8” " 25 gauge metal studs, 24” " on center with R-11 insulation and 5/8” " type “"X” " sheetrock full height both sides (the height of the wall may be adjusted for return air plenium). Tenant interior walls/ceiling height (floor to underside of acoustical ceiling), 3 5/8” " 25 gauge studs, 24” " on center with 5/8” " sheetrock on each side and J-mold at top. Finish: Smooth (level 4) wall. Light fixtures: 2’ x 4’ three lamp fixtures with 18 cell parabolic lenses or other fixtures mutually acceptable to Tenant and Landlord. Downlight and wall washers as accent lighting in conference rooms and reception areas as appropriate. Exit lights: Quantity as required by code, to be specified by Tenant subject to Landlord’s approval. Outlets and switches: Private offices receive two duplex electrical outlets, two telephone and data outlets (ring/string) and one dual light switch. Conference rooms receive four duplex outlets, two telephone and data outlets (ring/string) and one dual light switch. All other rooms are addressed based on specific layouts. Any changes to the foregoing specifications shall be subject to approval by Landlord.
Appears in 1 contract