{"component": "clause", "props": {"groups": [{"snippet": "Capacity Test Steps Field Testing Parameters PV Plant Capacity Test Data Compilation and Reduction Generation of Performance Curve", "samples": [{"hash": "9nQmwEy3o2U", "uri": "/contracts/9nQmwEy3o2U#capacity-test", "label": "Membership Interest Purchase, Project Development and Construction Management Agreement", "score": 27.6680355921, "published": true}, {"hash": "2Y4yPVnbkx3", "uri": "/contracts/2Y4yPVnbkx3#capacity-test", "label": "Membership Interest Purchase, Project Development and Construction Management Agreement", "score": 27.6666666667, "published": true}, {"hash": "iJnPz10reKo", "uri": "/contracts/iJnPz10reKo#capacity-test", "label": "Membership Interest Purchase, Project Development and Construction Management Agreement", "score": 27.1820670773, "published": true}], "size": 4, "snippet_links": [{"key": "testing-parameters", "type": "clause", "offset": [26, 44]}, {"key": "pv-plant-capacity", "type": "definition", "offset": [45, 62]}, {"key": "test-data", "type": "definition", "offset": [63, 72]}], "hash": "f24a128bad3cd766aaaf067d29bb8fde", "id": 2}, {"snippet": "Capacity Test Steps Field Testing", "samples": [{"hash": "chhc4mNJR6S", "uri": "/contracts/chhc4mNJR6S#capacity-test", "label": "Membership Interest Purchase, Project Development and Construction Management Agreement", "score": 34.3255053801, "published": true}, {"hash": "9nQmwEy3o2U", "uri": "/contracts/9nQmwEy3o2U#capacity-test", "label": "Membership Interest Purchase, Project Development and Construction Management Agreement", "score": 27.6680355921, "published": true}, {"hash": "2NyBUjp3NOl", "uri": "/contracts/2NyBUjp3NOl#capacity-test", "label": "Membership Interest Purchase, Project Development and Construction Management Agreement", "score": 27.6666666667, "published": true}], "size": 5, "snippet_links": [{"key": "field-testing", "type": "clause", "offset": [20, 33]}], "hash": "7c2043edb91bead23790e0ac128ed645", "id": 1}, {"snippet": "The plant will be operated with the following activities to be performed during the Capacity Test: -- Equipment status will be determined in order to establish that all necessary systems and equipment are operational and functional prior to the commencement of the test. Changes in equipment status and the time of status change will be recorded in the operator log. A copy of the operator log will be provided to the test coordinator by operations personnel during the Capacity Test. -- The facility and equipment will be operated within normal design limits of the equipment and in a manner consistent with good utility practices for continuous long-term operation.", "samples": [{"hash": "8XqeXdnwch7", "uri": "/contracts/8XqeXdnwch7#capacity-test", "label": "Engineering, Procurement and Construction Agreement (Tenaska Georgia Partners Lp)", "score": 18.0, "published": true}, {"hash": "6M2nKCS1xeA", "uri": "/contracts/6M2nKCS1xeA#capacity-test", "label": "Engineering, Procurement and Construction Agreement (Tenaska Georgia Partners Lp)", "score": 18.0, "published": true}], "size": 2, "snippet_links": [{"key": "the-plant", "type": "clause", "offset": [0, 9]}, {"key": "activities-to-be-performed", "type": "clause", "offset": [46, 72]}, {"key": "equipment-status", "type": "definition", "offset": [102, 118]}, {"key": "to-establish", "type": "clause", "offset": [147, 159]}, {"key": "systems-and-equipment", "type": "clause", "offset": [179, 200]}, {"key": "commencement-of-the", "type": "clause", "offset": [245, 264]}, {"key": "changes-in", "type": "clause", "offset": [271, 281]}, {"key": "status-change", "type": "definition", "offset": [315, 328]}, {"key": "operator-log", "type": "definition", "offset": [353, 365]}, {"key": "of-the-operator", "type": "clause", "offset": [374, 389]}, {"key": "test-coordinator", "type": "clause", "offset": [418, 434]}, {"key": "operations-personnel", "type": "clause", "offset": [438, 458]}, {"key": "facility-and-equipment", "type": "clause", "offset": [492, 514]}, {"key": "design-limits", "type": "definition", "offset": [546, 559]}, {"key": "the-equipment", "type": "definition", "offset": [563, 576]}, {"key": "consistent-with", "type": "clause", "offset": [593, 608]}, {"key": "good-utility-practices", "type": "definition", "offset": [609, 631]}], "hash": "22924d414084b44974c718575d64d3e0", "id": 3}, {"snippet": "After successful completion of the Acceptance Tests, Seller shall be allowed to conduct Capacity Tests (subject to inspection by Company) in accordance with the testing procedures set forth in Attachment W (Capacity Test Procedures), to determine the Demonstrated Firm Capacity of the Facility and whether Capacity Charge payments may be EXECUTION VERSIONPuna Geothermal Venture ARTICLE 556 adjusted in accordance with Section 5.1(F) (Capacity Shortfall) and should begin in accordance with Section 5.1(G) (Commencement of Capacity Charge Payments).", "samples": [{"hash": "bzH8vNv9mWm", "uri": "/contracts/bzH8vNv9mWm#capacity-test", "label": "Power Purchase Agreement (Hawaiian Electric Co Inc)", "score": 31.1574264203, "published": true}], "size": 2, "snippet_links": [{"key": "acceptance-tests", "type": "definition", "offset": [35, 51]}, {"key": "seller-shall", "type": "clause", "offset": [53, 65]}, {"key": "capacity-tests", "type": "clause", "offset": [88, 102]}, {"key": "inspection-by-company", "type": "clause", "offset": [115, 136]}, {"key": "in-accordance-with", "type": "definition", "offset": [138, 156]}, {"key": "testing-procedures", "type": "clause", "offset": [161, 179]}, {"key": "capacity-test-procedures", "type": "definition", "offset": [207, 231]}, {"key": "determine-the", "type": "clause", "offset": [237, 250]}, {"key": "firm-capacity", "type": "clause", "offset": [264, 277]}, {"key": "the-facility", "type": "definition", "offset": [281, 293]}, {"key": "payments-may-be", "type": "clause", "offset": [322, 337]}, {"key": "capacity-shortfall", "type": "clause", "offset": [435, 453]}, {"key": "commencement-of", "type": "clause", "offset": [507, 522]}], "hash": "2f905ffbc72285b6a2881e6deaa3c0ab", "id": 4}, {"snippet": "A capacity test shall establish the Rated Capacity for a Unit and shall consist of continuous, full load operation for twenty-four hours. The result of any capacity test shall be the net electrical capacity averaged over the duration of the capacity test, expressed in MW and measured at the Point of Interconnection. Upon the conclusion of the initial capacity test, Seller may elect to either (a) within five days submit the results of such capacity test to Purchaser, witha copy to the engineer, or (b) deliver a notice to Purchaser with a copy to the engineer stating Seller's intention to perform a second capacity test no earlier than two days and no later than seven days after the Purchaser's receipt of such notice. If Seller electes to perform such second capacity test, Seller shall, within five days after the conclusion of such capacity test submit to Purchaser (\"Sellers Notice\") with a copy to the engineer, the results of either the initial capacity test or the second capacity test, as Seller may elect.", "samples": [{"hash": "4o2RMc8aufA", "uri": "/contracts/4o2RMc8aufA#capacity-test", "label": "Power Purchase and Sale Contract (Aes China Generating Co LTD)", "score": 18.0, "published": true}], "size": 2, "snippet_links": [{"key": "rated-capacity", "type": "clause", "offset": [36, 50]}, {"key": "a-unit", "type": "clause", "offset": [55, 61]}, {"key": "consist-of", "type": "clause", "offset": [72, 82]}, {"key": "full-load", "type": "definition", "offset": [95, 104]}, {"key": "any-capacity", "type": "definition", "offset": [152, 164]}, {"key": "the-net", "type": "clause", "offset": [179, 186]}, {"key": "electrical-capacity", "type": "definition", "offset": [187, 206]}, {"key": "duration-of-the", "type": "clause", "offset": [225, 240]}, {"key": "point-of-interconnection", "type": "definition", "offset": [292, 316]}, {"key": "conclusion-of", "type": "clause", "offset": [327, 340]}, {"key": "initial-capacity-test", "type": "definition", "offset": [345, 366]}, {"key": "five-days", "type": "definition", "offset": [406, 415]}, {"key": "the-engineer", "type": "definition", "offset": [485, 497]}, {"key": "notice-to-purchaser", "type": "definition", "offset": [516, 535]}, {"key": "with-a-copy-to", "type": "clause", "offset": [536, 550]}, {"key": "days-after", "type": "definition", "offset": [674, 684]}, {"key": "the-purchaser", "type": "definition", "offset": [685, 698]}, {"key": "receipt-of", "type": "clause", "offset": [701, 711]}, {"key": "seller-shall", "type": "clause", "offset": [781, 793]}, {"key": "submit-to", "type": "clause", "offset": [855, 864]}, {"key": "as-seller", "type": "clause", "offset": [1000, 1009]}], "hash": "6db6f54400ca50850beb2265e034ebba", "id": 5}, {"snippet": "After successful completion of the Acceptance Tests in Section 1.a. of this Attachment N (Acceptance Test General Criteria), Seller shall be permitted to conduct the Capacity Test pursuant to Section 5.1(D) (Capacity Test) in accordance with the procedures set forth in Attachment W (Capacity Test Procedures).", "samples": [{"hash": "bzH8vNv9mWm", "uri": "/contracts/bzH8vNv9mWm#capacity-test", "label": "Power Purchase Agreement (Hawaiian Electric Co Inc)", "score": 31.1574264203, "published": true}], "size": 2, "snippet_links": [{"key": "acceptance-tests", "type": "definition", "offset": [35, 51]}, {"key": "general-criteria", "type": "definition", "offset": [106, 122]}, {"key": "seller-shall", "type": "clause", "offset": [125, 137]}, {"key": "pursuant-to-section", "type": "definition", "offset": [180, 199]}, {"key": "in-accordance-with", "type": "definition", "offset": [223, 241]}, {"key": "the-procedures", "type": "definition", "offset": [242, 256]}, {"key": "capacity-test-procedures", "type": "definition", "offset": [284, 308]}], "hash": "1bf2cc03d47ebb161c026df9f512eeca", "id": 6}, {"snippet": "a. Capacity testing is used to establish the Firm Capacity according to the procedures defined here.\nb. At least one (1) successful Capacity Test must be completed prior to the Commercial Operation Date.\nc. Acceptance Testing must be completed prior to the first Capacity Test in accordance with Section A.f. of this Attachment D.\nd. When the Facility is ready for a Capacity Test, the Seller shall notify the Company at least seven (7) Days prior to such test and shall coordinate with the Company. The Seller shall perform and the Company shall monitor such test no earlier than seven (7) Days after the Company\u2019s receipt of such notice.\ne. The Capacity Test shall be performed as follows:\ni. The test shall last for forty-eight (48) hours and shall be scheduled on the start-up plan provided by the Seller to the Company in accordance with Section 5.1A.\nii. During the test period, the Seller will operate all equipment in accordance with normal operational parameters practices.\niii. During the test period, the Facility shall operate in accordance with the dispatch instructions of the Company\u2019s System Operator, subject in all cases to Good Engineering and Operating Practices, the Seller\u2019s permit limits, and the safety and design limits of the Facility as specified by the applicable equipment manufacturers.\niv. If, during the Capacity Test period, the Company\u2019s System Operator specifies less than maximum output, the period of testing will be extended to achieve forty-eight (48) hours with no reduction by the System Operator. The Firm Capacity will be declared including only the hours where the Facility was dispatched at maximum output.\nv. If the Seller and the Company are satisfied with the Capacity Test, Firm Capacity shall be designated by the Seller as follows:\nvi. If the test was performed prior to the Commercial Operation Date, or was performed during the Corrective Period, the Firm Capacity shall be designated by the Seller as up to the minimum average capacity level that the Facility is able to sustain over a fifteen (15) minute interval in which the Facility is being dispatched at maximum capacity; provided that the Seller may not set the Firm Capacity at a level in excess of the Committed Capacity in accordance with the terms of this Agreement.\nvii. If the test is being done after the Corrective Period, the Firm Capacity shall be designated by the Seller as up to the minimum average capacity level that the Facility is able to sustain over a fifteen (15) minute interval in which the Facility is being dispatched at maximum capacity; provided that the Seller may not set the Firm Capacity at a level in excess of the prior Firm Capacity in accordance with the terms of this Agreement and may not be set to a level greater than the Committed Capacity.\nviii. For the purpose of defining the Firm Capacity, the minimum average capacity level shall be obtained from the metering used for measuring the integrated Net Electric Energy Output as discussed in Section 3.2E(1).\nix. No more than thirty (30) MW of the Firm Capacity may be provided by the Existing Facility.\nx. The Capacity test is successful if it is agreed by the Seller and the Company and the Firm Capacity is greater than thirty (30) MW.\nxi. If either the Seller or the Company reasonably believes that an abnormal condition occurred which may have adversely impacted the Capacity Test, such Capacity Test shall be deemed to be invalid and a re-test shall be done. The Seller shall pay all costs associated with any retest, unless the abnormal condition was caused by the Company, in which case the Company shall pay such retest costs.\nxii. If, following two (2) re-tests, the Parties cannot agree that such Capacity Test produced accurate and reliable results, the Parties shall hire a Qualified Independent Engineering Company, from the list set forth in Attachment H, to observe a third test and declare the Firm Capacity. The cost of such Qualified Independent Engineering Company shall be shared equally by the Parties.\nxiii. The Parties shall not hire a Qualified Independent Engineering Company if following two(2) or more re-tests both Parties agree that such Capacity Test produced inaccurate or unreliable results; provided that the provisions regarding the hiring of a Qualified Independent Engineering Company shall apply if the Parties fail to agree to the results of any subsequent test.\nxiv. If the Seller is unable to complete the Acceptance Test or a subsequent test for any reason, it shall be permitted to re-conduct such test.", "samples": [{"hash": "2ulJ4umcQOl", "uri": "/contracts/2ulJ4umcQOl#capacity-test", "label": "Power Purchase Agreement (Hawaiian Electric Industries Inc)", "score": 23.1273100616, "published": true}], "size": 2, "snippet_links": [{"key": "capacity-testing", "type": "clause", "offset": [3, 19]}, {"key": "to-establish", "type": "clause", "offset": [28, 40]}, {"key": "firm-capacity", "type": "clause", "offset": [45, 58]}, {"key": "according-to", "type": "definition", "offset": [59, 71]}, {"key": "the-procedures", "type": "definition", "offset": [72, 86]}, {"key": "must-be-completed", "type": "clause", "offset": [146, 163]}, {"key": "prior-to-the-commercial-operation-date", "type": "clause", "offset": [164, 202]}, {"key": "acceptance-testing", "type": "definition", "offset": [207, 225]}, {"key": "in-accordance-with", "type": "definition", "offset": [277, 295]}, {"key": "the-facility", "type": "definition", "offset": [339, 351]}, {"key": "the-seller-shall", "type": "clause", "offset": [382, 398]}, {"key": "notify-the", "type": "clause", "offset": [399, 409]}, {"key": "days-prior", "type": "definition", "offset": [437, 447]}, {"key": "the-company-shall", "type": "clause", "offset": [529, 546]}, {"key": "after-the-company", "type": "definition", "offset": [596, 613]}, {"key": "receipt-of", "type": "clause", "offset": [616, 626]}, {"key": "by-the-seller", "type": "clause", "offset": [795, 808]}, {"key": "company-in", "type": "clause", "offset": [816, 826]}, {"key": "test-period", "type": "definition", "offset": [872, 883]}, {"key": "seller-will", "type": "clause", "offset": [889, 900]}, {"key": "all-equipment", "type": "clause", "offset": [909, 922]}, {"key": "operational-parameters", "type": "definition", "offset": [949, 971]}, {"key": "facility-shall", "type": "clause", "offset": [1016, 1030]}, {"key": "instructions-of-the-company", "type": "clause", "offset": [1071, 1098]}, {"key": "system-operator", "type": "definition", "offset": [1101, 1116]}, {"key": "in-all-cases", "type": "clause", "offset": [1126, 1138]}, {"key": "good-engineering-and-operating-practices", "type": "definition", "offset": [1142, 1182]}, {"key": "safety-and", "type": "clause", "offset": [1220, 1230]}, {"key": "design-limits", "type": "definition", "offset": [1231, 1244]}, {"key": "as-specified", "type": "clause", "offset": [1261, 1273]}, {"key": "the-applicable", "type": "clause", "offset": [1277, 1291]}, {"key": "period-of-testing", "type": "clause", "offset": [1428, 1445]}, {"key": "no-reduction", "type": "clause", "offset": [1502, 1514]}, {"key": "the-system", "type": "definition", "offset": [1518, 1528]}, {"key": "the-seller-and-the-company", "type": "clause", "offset": [1658, 1684]}, {"key": "corrective-period", "type": "definition", "offset": [1881, 1898]}, {"key": "maximum-capacity", "type": "definition", "offset": [2114, 2130]}, {"key": "provided-that", "type": "clause", "offset": [2132, 2145]}, {"key": "committed-capacity", "type": "clause", "offset": [2215, 2233]}, {"key": "terms-of-this-agreement", "type": "clause", "offset": [2257, 2280]}, {"key": "for-the-purpose-of", "type": "definition", "offset": [2797, 2815]}, {"key": "energy-output", "type": "definition", "offset": [2962, 2975]}, {"key": "existing-facility", "type": "definition", "offset": [3085, 3102]}, {"key": "agreed-by", "type": "clause", "offset": [3148, 3157]}, {"key": "the-company-and-the", "type": "clause", "offset": [3173, 3192]}, {"key": "reasonably-believes", "type": "definition", "offset": [3279, 3298]}, {"key": "abnormal-condition", "type": "definition", "offset": [3307, 3325]}, {"key": "all-costs", "type": "definition", "offset": [3487, 3496]}, {"key": "associated-with", "type": "definition", "offset": [3497, 3512]}, {"key": "by-the-company", "type": "clause", "offset": [3566, 3580]}, {"key": "the-parties-shall", "type": "clause", "offset": [3763, 3780]}, {"key": "a-qualified", "type": "clause", "offset": [3786, 3797]}, {"key": "attachment-h", "type": "definition", "offset": [3858, 3870]}, {"key": "cost-of", "type": "definition", "offset": [3931, 3938]}, {"key": "by-the-parties", "type": "clause", "offset": [4010, 4024]}, {"key": "both-parties-agree", "type": "clause", "offset": [4140, 4158]}, {"key": "provisions-regarding", "type": "clause", "offset": [4244, 4264]}, {"key": "agree-to", "type": "clause", "offset": [4358, 4366]}, {"key": "the-seller-is", "type": "clause", "offset": [4411, 4424]}, {"key": "the-acceptance", "type": "clause", "offset": [4444, 4458]}, {"key": "for-any-reason", "type": "clause", "offset": [4485, 4499]}], "hash": "defb986b2be96083e5a3b56881096503", "id": 7}, {"snippet": "Prior to achieving Commercial Operations and in each Measurement Period, unless waived by Company, Seller shall demonstrate that the Facility maintains output, provided by the Company, through a control setpoint, as measured at the Point of Interconnection, and is able to continuously dispatch the full Contract Capacity (the \u201cCapacity Test\u201d). The Capacity Test can only be performed when the Facility is at the lower of: (i) its maximum State of Charge or (ii) 100% State of Charge prior to the start of the Capacity Test and during the Capacity Test the Company Dispatch/Charge allows for continuous dispatch of the Facility to 0% State of Charge with energy delivered to the Point of Interconnection. For the purposes of evaluating the Capacity Test, the \u201cCapacity Ratio\u201d shall be equal to the number, expressed as a percentage, equal to the total MWh delivered to the Point of Interconnection during the Capacity Test, divided by the Contract Capacity. Further, the Capacity Test will be deemed to be \u201cpassed\u201d or \u201csatisfied\u201d to the extent the Capacity Ratio is not less than 100% (the \u201cCapacity Performance Metric\u201d). Except for the Capacity Test conducted prior to Commercial Operations, Seller shall, in lieu of conducting a Capacity Test, be permitted to demonstrate satisfaction of the Capacity Performance Metric by reference to the operational data reflecting the net output of the Facility from the Point of Interconnection for such Measurement Period. Any Capacity Test, other than where the Contract Capacity is demonstrated by reference to operational data reflecting the net output of the Facility as provided below, shall be performed at a time reasonably requested by the Company in its sole discretion. Within a Measurement Period, Seller shall be permitted up to a total of three (3) Capacity Tests to demonstrate satisfaction of the Capacity Performance Metric for such Measurement Period, unless additional Capacity Tests are authorized by Company. Company shall provide notice to Seller no less than three (3) Business Days prior to conducting a Capacity Test. At any time prior to the conduct of the third (3rd) Capacity Test noticed by Company for a Measurement Period, Seller may demonstrate satisfaction of the Capacity Performance Metric by reference to operational data reflecting the net output of the Facility from the Point of Interconnection for such Measurement Period. If, during a Measurement Period, Seller both fails to pass a Capacity Test noticed by Company and fails to demonstrate satisfaction of the Capacity Performance Metric by reference to operational data for such Measurement Period, the Facility shall nevertheless be deemed to have satisfied the Capacity Performance Metric for the applicable Measurement Period if either (i) Company failed to notice at least three (3) Capacity Tests during such Measurement Period, or (ii) Seller was unable to perform at least two (2) such noticed Capacity Tests during such Measurement Period due to (a) conditions on the Company System other than Seller-Attributable Unavailability or (b) an act or omission by Company. Company shall have the right to attend, observe and receive the results of all Capacity Tests. Seller shall provide to Company the results of each Capacity Test (including time stamped graphs of system performance based in operational data or test data) no later than ten (10) Business Days after the performance of such Capacity Test.", "samples": [{"hash": "alM5My1bxmE", "uri": "/contracts/alM5My1bxmE#capacity-test", "label": "Energy Storage Power Purchase Agreement", "score": 26.6536618754, "published": true}], "size": 1, "snippet_links": [{"key": "commercial-operations", "type": "definition", "offset": [19, 40]}, {"key": "seller-shall", "type": "clause", "offset": [99, 111]}, {"key": "the-facility", "type": "definition", "offset": [129, 141]}, {"key": "by-the-company", "type": "clause", "offset": [169, 183]}, {"key": "point-of-interconnection", "type": "definition", "offset": [232, 256]}, {"key": "to-continuously", "type": "clause", "offset": [270, 285]}, {"key": "contract-capacity", "type": "definition", "offset": [304, 321]}, {"key": "maximum-state-of-charge", "type": "definition", "offset": [431, 454]}, {"key": "prior-to-the", "type": "clause", "offset": [484, 496]}, {"key": "company-dispatch", "type": "clause", "offset": [557, 573]}, {"key": "for-the-purposes-of", "type": "clause", "offset": [705, 724]}, {"key": "capacity-ratio", "type": "definition", "offset": [760, 774]}, {"key": "equal-to", "type": "definition", "offset": [785, 793]}, {"key": "a-percentage", "type": "definition", "offset": [819, 831]}, {"key": "the-total", "type": "clause", "offset": [842, 851]}, {"key": "divided-by", "type": "clause", "offset": [924, 934]}, {"key": "to-the-extent", "type": "clause", "offset": [1030, 1043]}, {"key": "capacity-performance-metric", "type": "definition", "offset": [1091, 1118]}, {"key": "in-lieu-of", "type": "clause", "offset": [1207, 1217]}, {"key": "satisfaction-of", "type": "clause", "offset": [1274, 1289]}, {"key": "reference-to", "type": "definition", "offset": [1325, 1337]}, {"key": "operational-data", "type": "definition", "offset": [1342, 1358]}, {"key": "net-output", "type": "definition", "offset": [1374, 1384]}, {"key": "any-capacity", "type": "definition", "offset": [1464, 1476]}, {"key": "where-the-contract", "type": "clause", "offset": [1494, 1512]}, {"key": "requested-by", "type": "definition", "offset": [1672, 1684]}, {"key": "company-in", "type": "clause", "offset": [1689, 1699]}, {"key": "sole-discretion", "type": "clause", "offset": [1704, 1719]}, {"key": "capacity-tests", "type": "clause", "offset": [1803, 1817]}, {"key": "additional-capacity", "type": "definition", "offset": [1917, 1936]}, {"key": "authorized-by", "type": "definition", "offset": [1947, 1960]}, {"key": "notice-to-seller", "type": "clause", "offset": [1992, 2008]}, {"key": "days-prior", "type": "definition", "offset": [2041, 2051]}, {"key": "at-any-time", "type": "clause", "offset": [2083, 2094]}, {"key": "conduct-of-the", "type": "clause", "offset": [2108, 2122]}, {"key": "by-company-for", "type": "clause", "offset": [2157, 2171]}, {"key": "facility-shall", "type": "clause", "offset": [2636, 2650]}, {"key": "applicable-measurement-period", "type": "definition", "offset": [2732, 2761]}, {"key": "company-system", "type": "definition", "offset": [3009, 3023]}, {"key": "act-or-omission", "type": "clause", "offset": [3080, 3095]}, {"key": "to-attend", "type": "clause", "offset": [3137, 3146]}, {"key": "to-company", "type": "definition", "offset": [3224, 3234]}, {"key": "system-performance", "type": "clause", "offset": [3303, 3321]}, {"key": "test-data", "type": "definition", "offset": [3351, 3360]}, {"key": "days-after", "type": "definition", "offset": [3394, 3404]}, {"key": "the-performance", "type": "clause", "offset": [3405, 3420]}], "hash": "9983516229e005753957a6ee40f17211", "id": 8}, {"snippet": "The Capacity Test shall determine the Net Deliverable Capacity of the Facility. The Facility shall be tested for a period of twelve (12) hours (the \u201ctest period\u201d). Data shall be recorded once every ten (10) minutes for the test period. The test period shall be used to verify the Facility capacity, during which the Geothermal Fluid conditions, ambient air wet bulb temperature and power factor shall be within the ranges covered by the Correction Curves, but in any case the OEC stipulated nameplate capacity shall not be exceeded. Out of the test period, one continuous six (6) hour period shall be selected for the Capacity Test. The six hour Capacity Test period shall be selected as the one during the test period that provides the Net Power Correction Factor (CF, as defined in Schedule A of this Exhibit D) that is closest to the value of 1.0 (one point zero) when averaged over the six hour test interval. Performance Test - Raft River EPC Contract, Exhibit D Rev 0 \u2013 12/05/05 The test results will be recorded per the attached \u201cTest Record of Capacity Test\u201d, or similar form as may be agreed by the Contractor and Company at the time of the test. The Capacity Test results shall be calculated in the following manner: \u2022 The instrument readings taken during the test period and the approved Correction Curves shall be used to calculate the corrected Net Deliverable Capacity (NDC) of the Facility in accordance with formula 2 of Schedule A to this Exhibit D. \u2022 Contractor shall compare the NDC with the Performance Guarantee. If such comparison shows that the Facility has not achieved the Performance Guarantee, the Capacity Test may be repeated thereafter in accordance with Section 4 of this Exhibit D.", "samples": [{"hash": "detAgYFFR4h", "uri": "/contracts/detAgYFFR4h#capacity-test", "label": "Engineering, Procurement and Construction Contract (Us Geothermal Inc)", "score": 19.0, "published": true}], "size": 1, "snippet_links": [{"key": "the-net", "type": "clause", "offset": [34, 41]}, {"key": "the-facility", "type": "definition", "offset": [66, 78]}, {"key": "facility-shall", "type": "clause", "offset": [84, 98]}, {"key": "period-of", "type": "definition", "offset": [115, 124]}, {"key": "test-period", "type": "definition", "offset": [149, 160]}, {"key": "to-verify", "type": "definition", "offset": [266, 275]}, {"key": "facility-capacity", "type": "definition", "offset": [280, 297]}, {"key": "geothermal-fluid", "type": "definition", "offset": [316, 332]}, {"key": "ambient-air", "type": "definition", "offset": [345, 356]}, {"key": "power-factor", "type": "clause", "offset": [382, 394]}, {"key": "covered-by", "type": "definition", "offset": [422, 432]}, {"key": "correction-curves", "type": "definition", "offset": [437, 454]}, {"key": "nameplate-capacity", "type": "clause", "offset": [491, 509]}, {"key": "correction-factor", "type": "definition", "offset": [747, 764]}, {"key": "schedule-a", "type": "clause", "offset": [784, 794]}, {"key": "exhibit-d", "type": "definition", "offset": [803, 812]}, {"key": "the-value", "type": "clause", "offset": [833, 842]}, {"key": "test-interval", "type": "definition", "offset": [899, 912]}, {"key": "performance-test", "type": "definition", "offset": [914, 930]}, {"key": "epc-contract", "type": "definition", "offset": [944, 956]}, {"key": "test-results", "type": "definition", "offset": [989, 1001]}, {"key": "record-of", "type": "clause", "offset": [1042, 1051]}, {"key": "by-the-contractor", "type": "clause", "offset": [1101, 1118]}, {"key": "and-company", "type": "clause", "offset": [1119, 1130]}, {"key": "time-of-the", "type": "clause", "offset": [1138, 1149]}, {"key": "the-instrument", "type": "clause", "offset": [1229, 1243]}, {"key": "calculate-the", "type": "clause", "offset": [1334, 1347]}, {"key": "in-accordance-with", "type": "definition", "offset": [1405, 1423]}, {"key": "contractor-shall", "type": "clause", "offset": [1469, 1485]}, {"key": "the-performance-guarantee", "type": "clause", "offset": [1507, 1532]}, {"key": "section-4", "type": "definition", "offset": [1685, 1694]}], "hash": "653c8f0b96eea9d648416c5086c6e81e", "id": 9}, {"snippet": "The plant will be operated with the following activities to be performed during the Capacity Test:", "samples": [{"hash": "47PQdZTG2P7", "uri": "/contracts/47PQdZTG2P7#capacity-test", "label": "Power Purchase Agreement (Tenaska Georgia Partners Lp)", "score": 18.0, "published": true}], "size": 1, "snippet_links": [{"key": "the-plant", "type": "clause", "offset": [0, 9]}, {"key": "activities-to-be-performed", "type": "clause", "offset": [46, 72]}], "hash": "21b4fdfb16dc056845fd1da62d7990d2", "id": 10}], "next_curs": "ClYSUGoVc35sYXdpbnNpZGVyY29udHJhY3RzcjILEhZDbGF1c2VTbmlwcGV0R3JvdXBfdjU2IhZjYXBhY2l0eS10ZXN0IzAwMDAwMDBhDKIBAmVuGAAgAA==", "clause": {"size": 24, "title": "Capacity Test", "children": [["performance-of-capacity-tests", "Performance of Capacity Tests"], ["failure-to-satisfy-capacity-tests", "Failure to Satisfy Capacity Tests"]], "parents": [["test-conditions", "Test Conditions"], ["performance-tests", "Performance Tests"], ["protective-relays-synchronizing-and-metering", "Protective Relays, Synchronizing and Metering"], ["security-system", "Security System"], ["final-report", "Final Report"]], "id": "capacity-test", "related": [["stability-testing", "Stability Testing", "Stability Testing"], ["performance-testing", "Performance Testing", "Performance Testing"], ["acceptance-testing", "Acceptance Testing", "Acceptance Testing"], ["performance-tests", "Performance Tests", "Performance Tests"], ["acceptance-tests", "Acceptance Tests", "Acceptance Tests"]], "related_snippets": [], "updated": "2025-07-07T12:37:48+00:00"}, "json": true, "cursor": ""}}