Boiler Blowdown System. A continuous boiler water blowdown system shall be provided for each steam drum. A continuous boiler blowdown quality sampling and indicating system shall be provided by Contractor as part of the boiler blowdown system. The HRSG manufacturer shall guarantee the steam purity at the main steam outlet based on the steam turbine manufacturer's steam purity requirements and, therefore, must set the drum water concentration limits, which consequently establishes the blowdown rate. Actual HRSG blowdown rate shall be based on the data supplied. However for design purposes, a 4 percent blowdown rate shall be utilized. Boiler drum water conductivity sensing equipment shall be provided and continuous indication with alarm limit monitoring shall be provided in the distributed control system. The blowdown rate shall be adjusted based on conductivity through the DCS system. The Contractor shall provide a boiler blowdown system designed to recover the heat in the blowdown water. Boiler blowdown from each HRSG shall be discharged to a continuous blowdown tank. Steam from the continuous blowdown tank shall be recovered. Water from the continuous blowdown tank shall discharge to an atmospheric blowdown tank. The continuous blowdown tank shall be designed to separate flash steam from the heat recovery boiler blowdown efficiently and to minimize erosion and operational problems. The following items should be considered when designing the continuous and atmospheric blowdown tanks and there associated system:
AutoNDA by SimpleDocs

Related to Boiler Blowdown System

  • SPRINKLER SYSTEM If there now is or shall be installed in the Building a "sprinkler system", and such system or any of its appliances shall be damaged or injured or not in proper working order by reason of any act or omission of Tenant, Tenant's agents, servants, employees, licensees or visitors, Tenant shall forthwith restore the same to good working condition at its own expense; and if the New York Board of Fire Underwriters or the New York Fire Insurance Rating Organization or any bureau, department or official of the state or city government, shall require or recommend that any changes, modifications, alterations or additional sprinkler heads or other equipment be made or supplied by reason of Tenant's business, or the location of the partitions, trade fixtures, or other contents of the Premises, Tenant shall, at Tenant's expense, promptly make and supply such changes, modifications, alterations, additional sprinkler heads or other equipment.

  • System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.

  • Safety Glasses 10.3.1 Where a teacher is considered to be working in an “eye danger” area, the teacher shall receive a personal issue of standard neutral safety glasses which shall remain the property of the employer.

  • Electrical Provide drawings for the following systems:

  • PFPC System PFPC shall retain title to and ownership of any and all data bases, computer programs, screen formats, report formats, interactive design techniques, derivative works, inventions, discoveries, patentable or copyrightable matters, concepts, expertise, patents, copyrights, trade secrets, and other related legal rights utilized by PFPC in connection with the services provided by PFPC to the Fund.

  • Fire a. Driver to park vehicle in safe location and turn off engine.

  • System Upgrade Facilities and System Deliverability Upgrades Connecting Transmission Owner shall design, procure, construct, install, and own the System Upgrade Facilities and System Deliverability Upgrades described in Appendix A hereto. The responsibility of the Developer for costs related to System Upgrade Facilities and System Deliverability Upgrades shall be determined in accordance with the provisions of Attachment S to the NYISO OATT.

  • Safety Equipment Should the employment duties of an employee in the bargaining unit require use of any equipment or gear to insure the safety of the employee or others, the District agrees to furnish such equipment or gear.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Sprinklers Subject to any terms, conditions and limitations set forth herein, Landlord shall provide an operative sprinkler system consisting of mains, laterals, and heads “AS IS” on the date of delivery of the Premises to Tenant. Tenant shall pay for piping distribution, drops and relocation of, or additional, sprinkler system heads and Building firehose or firehose valve cabinets, if Tenant’s Plans and/or any applicable Laws necessitate such.

Time is Money Join Law Insider Premium to draft better contracts faster.