CONSTRUCTION OF THE QWEST SYSTEM Sample Clauses

CONSTRUCTION OF THE QWEST SYSTEM. 3.1 QWEST shall, at QWEST's sole cost and expense, be responsible for and shall effect the design, engineering, installation, and construction of those portions of the QWEST System not already constructed as of the date hereof in accordance with the System Route (as it may be modified pursuant to Section 1.1) and in conformity with (i) the construction specifications set forth in Exhibit C, (ii) industry standards and practices, and (iii) applicable Underlying Rights Requirements (as defined in Section 11.1). Such responsibilities shall include, without limitation, preparation of construction drawings, bills of materials, materials specifications and materials requisitions. Except for the existing fibers on Segments 11A, 00X, 00X, 00X, 00X and 12D (which are Corning SMF-DS) and any alternative fibers approved pursuant to the following sentence, all fiber included in the FRONTIER Fibers shall be Corning SMF-LS non-zero dispersion-shifted or Lucent Technologies True Wave and shall meet or exceed the applicable fiber specifications set forth in Exhibit E. QWEST may use alternative types of fiber equivalent to either of the aforementioned fibers; provided that (i) prior to any such use, QWEST meets with FRONTIER (and FRONTIER hereby agrees to so meet) to, cooperatively and in good faith, jointly evaluate the use of any such fiber and (ii) thereafter, FRONTIER approves the use of such fiber, which approval shall not be unreasonably withheld or delayed. QWEST agrees that, to the extent possible in light of the fiber already incorporated in Segments that have been constructed, in whole or in part, prior to the date hereof and the availability and cost of the fiber of a particular type and manufacture hereafter, fiber utilized with respect to the loops, rings and regions of the QWEST System shall be of the same type and manufacture, as depicted in the fiber deployment diagram set forth in Exhibit E-1 hereto, indicating the type of fiber QWEST currently plans to use in each such Segment. Any deviation from the planned fiber use set forth in the diagram must be approved by FRONTIER, which approval shall not be unreasonably withheld or delayed. 3.2 Subject to extension for delays described in Article XX, QWEST shall complete at QWEST's sole cost and expense, all construction, installation, and satisfactory Fiber Acceptance Testing (as defined in Section 4.1) of each of the Segments, including the provision of such Regeneration Facilities on such Segment as are requir...
AutoNDA by SimpleDocs
CONSTRUCTION OF THE QWEST SYSTEM. 11 ARTICLE IV.
CONSTRUCTION OF THE QWEST SYSTEM. 3.1 To the extent any Segment is not completed as of the date hereof, subject to the provisions of Sections 1.2 and 1.3, as applicable, QWEST shall design, engineer, install, construct, and test the QWEST System comprised of such Segments on the terms and subject to the conditions set forth herein.
CONSTRUCTION OF THE QWEST SYSTEM. 3.01 QWEST shall, at QWEST's sole cost and expense, be responsible for and shall effect the design, engineering, installation, and construction of those portions of the QWEST System not already constructed as of the date hereof in accordance with the construction specifications set forth in Exhibit B, industry standards and practices, and applicable Underlying Rights Requirements (as defined in Section 11.01). All fibers included in the BTI Fibers shall be Lucent Technologies True Wave and shall meet or exceed the fiber specifications set forth in Exhibit D. QWEST may use alternative types of fiber equivalent to the aforementioned fiber; provided that (a) prior to any such use, QWEST meets with BTI (and BTI hereby agrees to so meet) to, cooperatively and in good faith, jointly evaluate the use of any such fiber and (b) thereafter, BTI approves the use of such fiber, which approval shall not be unreasonably withheld or delayed.

Related to CONSTRUCTION OF THE QWEST SYSTEM

  • Construction of the Project The Corporation hereby represents that it has caused the Project to be completed and acknowledges that it shall not be entitled to any reimbursement for the cost of construction of the Project from the Authority, the Trustee or the Holders of the Bonds, nor shall it be entitled to any diminution or postponement of the payments required to be paid by the Corporation pursuant to this Participation Agreement or the Corporation Obligations. Section 3.04.

  • Construction of the Improvements Once development of the Property has commenced, the construction of the Improvements shall be pursued with due diligence and continuity, in a good and workmanlike manner, and in accordance with sound building and engineering practices, all applicable governmental requirements, and the Development Plan. Borrower shall not permit cessation of work for a period in excess of thirty (30) days during any period of time during which development on the Property is scheduled to be performed without the prior written consent of Lender, which may be given or withheld in Lender’s sole discretion, except for delays due to strikes, riots, acts of God, war, unavailability of labor or materials, governmental laws, regulations or restrictions and Borrower shall promptly notify Lender of any such delays; provided, however, that in no event shall work cease for a period in excess of sixty (60) days regardless of the cause. Borrower shall cause all materials supplied for, or intended to be utilized in, the development of any part of the Property, but not affixed to or incorporated into the Property, to be stored on the Property or at such other location as may be approved by Lender in writing, with adequate safeguards, as required by Lender, to prevent loss, theft, damage, or commingling with other materials or projects.

  • Construction, Etc Each covenant contained herein shall be construed (absent express provision to the contrary) as being independent of each other covenant contained herein, so that compliance with any one covenant shall not (absent such an express contrary provision) be deemed to excuse compliance with any other covenant. Where any provision herein refers to action to be taken by any Person, or which such Person is prohibited from taking, such provision shall be applicable whether such action is taken directly or indirectly by such Person. For the avoidance of doubt, all Schedules and Exhibits attached to this Agreement shall be deemed to be a part hereof.

  • Construction of Hotel (i) To Seller’s knowledge, the Hotel has been constructed in a good and workmanlike manner without encroachments except as noted on the Survey and in accordance in all material respects with the Construction Plans. To Seller’s knowledge, the Hotel has received all building permits and certificates of occupancy necessary for the operation thereof, and is in compliance with applicable zoning, platting, subdivision, health, safety and similar laws, rules, regulations, ordinances and codes.

  • Construction of the Tenant Improvements Landlord shall construct the Tenant Improvements in accordance with this exhibit and the construction contract to be executed by Landlord and its contractor(s). The construction contract for constructing the Tenant Improvements and the contractor(s) to perform the work shall be approved and/or selected, as the case may be, by Landlord at its sole and absolute discretion without the consent of Tenant.

  • Construction of Tenant Improvements Promptly following approval of the Final TI Working Drawings, Landlord shall apply for and use reasonable efforts to obtain the necessary permits and approvals to allow construction of Landlord’s TI Work. Upon receipt of such permits and approvals, Landlord shall, at Tenant’s expense (subject to the application of the Tenant Improvement Allowance provided in this Workletter, and subject to any other applicable provisions of the Lease or of this Workletter expressly making any specific item of expense or cost the responsibility of Landlord), diligently construct and complete Landlord’s TI Work substantially in accordance with the Approved TI Plans, subject to Unavoidable Delays and Tenant Delays (if any). Such construction shall be performed in a good and workmanlike manner and shall conform to all applicable governmental codes, laws and regulations in force at the time such work is completed. Without limiting the generality of the foregoing, Landlord shall be responsible for compliance of Landlord’s TI Work with the requirements of the Americans with Disabilities Act and all similar or related requirements pertaining to access by persons with disabilities, but nothing in this sentence shall be construed to make Landlord responsible for bearing the cost of any such compliance, to the extent the compliance work is reasonably attributable to or related to the particular nature or design of the Tenant Improvements or is for any other reason expressly made Tenant’s cost or responsibility under any applicable provision of the Lease or of this Workletter. Landlord shall have the right, in its sole discretion, to decide whether and to what extent to use union labor on or in connection with Landlord’s Work, and shall use the TI General Contractor to construct all of Landlord’s TI Work. Landlord and Tenant shall each have a right to approve all subcontractors engaged in connection with the construction of the Tenant Improvements and to review and approve all competitive bids for any elements of the Tenant Improvements, such approval in each instance not to be unreasonably withheld, conditioned or delayed by either party.

  • Construction of Project Purchaser shall (i) perform the Final Assembly Work which is set forth in Exhibit P hereto, (ii) perform all civil works (including roads, grading, maintenance facilities, meteorological towers and other items); (iii) perform all electrical works (including collection lines, Electrical Infrastructure, Transmission Facilities, Interconnection Facilities and other items); (iv) provide and install a remote terminal unit and cabling to the Substation, meteorological towers, and communications lines for the SCADA System to the Substation; and (v) provide any other items required for the operation of the Project; and

  • Installation Tenant may install and use Tenant's Lines and make connections and disconnections at the terminal blocks as described above, provided Tenant shall: (i) obtain Landlord's prior written approval of all aspects thereof, (ii) use an experienced and qualified contractor designated or approved in writing in advance by Landlord (whom Landlord may require to enter an access and indemnity agreement on Landlord's then standard form of agreement therefor), (iii) comply with such inside wire standards as Landlord may adopt from time to time, and all other provisions of this Lease, including Paragraph 8 respecting alterations, and the Building rules respecting access to the wire closets, (iv) not install Lines in the same sleeve, chaseway or other enclosure in close proximity with electrical wire, and not install PVC-coated Lines under any circumstances, (v) thoroughly test any riser Lines to which Tenant intends to connect any Lines to ensure that such riser Lines are available and are not then connected to or used for telephone, data transmission or any other purpose by any other party (whether or not Landlord has previously approved such connections), and not connect to any such unavailable or connected riser Lines, and (vi) not connect any equipment to the Lines which may create an electromagnetic field exceeding the normal insulation ratings of ordinary twisted pair riser cable or cause radiation higher than normal background radiation, unless the Lines therefor (including riser Lines) are appropriately insulated to prevent such excessive electromagnetic fields or radiation (and such insulation shall not be provided by the use of additional unused twisted pair Lines). As a condition to permitting installation of new Lines, Landlord may require that Tenant remove any existing Lines located in or serving the Premises.

  • Construction Management Landlord or its Affiliate or agent shall supervise the Work, make disbursements required to be made to the contractor, and act as a liaison between the contractor and Tenant and coordinate the relationship between the Work, the Building and the Building’s Systems. In consideration for Landlord’s construction supervision services, Tenant shall pay to Landlord a construction supervision fee equal to three percent (3%) of Tenant’s Costs specified in Section 7.

  • Completion of the Project (a) The completion of the Project shall be evidenced to the Trustee by a certificate signed by the Project Supervisor on behalf of the User stating that (1) construction of the Improvements has been completed in accordance with the plans and specifications approved by the User, (2) the Equipment has been acquired and installed in accordance with the User's instructions, (3) all Project Costs have been paid, and (4) all facilities and improvements necessary in connection with the Project have been acquired and installed and all costs and expenses incurred in connection therewith have been paid. Notwithstanding the foregoing, such certificate shall state that it is given without prejudice to any rights against any vendor, contractor, subcontractor or other person not a party to this Lease Agreement which exist at the date of such certificate or which may subsequently come into being. The Issuer and the User will cooperate in causing such certificate to be furnished to the Trustee.

Time is Money Join Law Insider Premium to draft better contracts faster.